1. Introduction
Thank you for choosing the FDIK T7 Diesel Air Heater. This all-in-one parking heater is designed to provide efficient and reliable heating for various applications, including houses, cabins, camping setups, RVs, boats, trucks, garages, and warehouses. It supports multiple power inputs (12V, 24V, and 220V) for versatile use. This manual provides essential information for the safe and effective operation and maintenance of your heater.


2. Safety Precautions
Please read and understand all safety instructions before operating the heater. Failure to follow these instructions may result in fire, electric shock, serious injury, or property damage.
- Environment: Do not use diesel heaters in environments with high humidity, conductive dust, flammable and explosive gases, dust, corrosive media, strong light, strong magnetism, high voltage, or high current.
- Power Supply: Ensure the power supply voltage is within the applicable range (DC24V for 18-32V, DC12V for 9-16V). Exceeding the applicable voltage range is strictly forbidden.
- Installation: The equipment must be installed strictly in accordance with the requirements and used under safe conditions.
- Exhaust Gas: The heater's exhaust pipe contains toxic gases (carbon monoxide, carbon dioxide). Ensure that exhaust gases are discharged smoothly to the outside or outside the car to avoid poisoning. Our company is not responsible for losses caused by installation errors.
- Air Ducts: When using the heater, ensure that all air ducts are unobstructed, with no bends, pressure, or blockages in the pipeline. This ensures heating efficiency and normal operation. Blocked channels can cause overheating, reduce efficiency, shorten equipment life, or cause damage.
- Fuel: Only use diesel as the fuel for the heater.
- Component Replacement: If the controller or external components are damaged, only use components of the same model and parameters, replaced by professionals.
- Overheating: If the heater is hot and the fan is not working normally, quickly cool the fuselage. Blow cold air into the combustion air intake to cool the fuselage to below 80°C to prevent high-temperature damage or fire.
3. Package Contents
Upon opening your FDIK T7 Diesel Air Heater package, please verify that all the following components are included:

- FDIK T7 Heater Unit
- Controller (LCD Switch)
- Remote Control
- 12V Power Cord
- 220V Power Adapter (for indoor heating)
- Silencer
- Tubing
- Hot Air Duct
- Buckles (x4)
- Screws
4. Specifications
The following table outlines the key specifications of the FDIK T7 Diesel Air Heater:

| Attribute | Specification |
|---|---|
| Model Name | FDIK-T7 |
| Item Type | Heating & Fans |
| Voltage | 12V / 24V / 220V |
| Fuel | Diesel |
| Switch Type | LCD Switch (LCD color screen) |
| Shell Material | Metal |
| Heating Space | Up to 20 m² |
| Working Temperature | -40℃ to 40℃ |
| Fuel Tank Capacity | 3.5 Liters |
| Fuel Consumption | 0.15-0.55 L/H (depending on temperature/power) |
| External Testing Certification | CE |
| Dimensions (L x H x W) | 370mm x 365mm x 155mm |
| Package Weight | 9.5 kg |
5. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your heater. Refer to the detailed instructions in the official PDF manual for comprehensive guidance.
5.1. Component Overview

5.2. Power Connection
- Identify the power interface on the heater: Red represents the positive pole, Black represents the negative pole.
- For 12V/24V operation, connect the appropriate power cord to your vehicle's battery or power source, ensuring correct polarity.
- For 220V indoor use, connect the provided 220V adapter to the heater and then plug it into a standard wall outlet.


5.3. Fuel Tank
- Fill the integrated 3.5L fuel tank with diesel fuel only.
- Ensure the fuel cap is securely closed after filling.
5.4. Exhaust and Air Ducts
- Connect the exhaust pipe and hot air duct as per the diagram in the official manual.
- Ensure the exhaust pipe leads outdoors or to a well-ventilated area to safely discharge toxic gases.
- Verify that all air ducts are unobstructed to allow for proper airflow and heating efficiency.

6. Operation
The FDIK T7 heater features an intuitive LCD control panel and a remote control for easy operation.
6.1. Control Panel Overview

The control panel features:
- Set Key: For entering function selection.
- Knob Switch: For rotating to switch gears/adjust values.
- OK Key: For confirming selections.
- Clock: Displays current time.
- Timing Schedule: For setting timed operations.
- Display Ambient Temperature: Shows the current ambient temperature.
- Display System Data and Parameters: Shows operational data.
6.2. Power On/Off
- Start Operation: In power-on standby state, press and hold the "knob switch" for 2 seconds to turn on the device.
- Stop Operation: In the start state, press and hold the "knob switch" button for 2 seconds. The device will enter the shut-down cooling process and display "OFF".
6.3. Operating Modes
- Power Mode (H1-H6): This mode consists of 6 gears (H1-H6), where H6 represents the maximum power. Rotate the "knob switch" to adjust the power gear.
- Temperature Mode: In this mode, you can set your desired temperature. Rotate the "knob switch" to adjust the temperature. The heater will maintain the set temperature by automatically turning on and off.
6.4. Setting the Heater Clock Time
- In the power-on standby state, long press the setting key to enter the function selection interface.
- Rotate the "knob switch" to navigate functions. When the "AC" logo appears, press the OK key to confirm.
- The heater will enter time setting mode. Adjust the time using the knob switch and confirm with the OK key.
- Note: If the heater power is cut off, the set time may not be accurate and needs to be reset after reconnecting power.
6.5. Timing Function
- In standby mode, long press the setting key to enter the function selection interface.
- Rotate the "knob switch" to navigate functions. When the "5F" logo appears, press the OK key to confirm. The heater will enter the timing function mode.
- Rotate the "knob switch" to select the desired start time (only integers can be selected).
- Press the OK button to confirm. The corresponding number will flash. When the heater clock time reaches the set start time, the heater will automatically start.
- Note: If the system is turned on or off manually or the power is turned off, the system will automatically exit the timing state.
6.6. Remote Control
The remote control allows you to turn the heater on/off and adjust settings from a distance. Under barrier-free conditions, the maximum remote control distance is approximately 30 meters.

7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your FDIK T7 Diesel Air Heater.
- Cleanliness: Keep the heater's exterior clean. Avoid dust accumulation, especially around air inlets and outlets.
- Air Ducts: Periodically check that all air ducts are free from obstructions. Clear any debris or blockages to maintain heating efficiency and prevent overheating.
- Fuel System: Ensure the fuel lines are clear and free from blockages or solidification, especially in low temperatures. Use clean diesel fuel.
- Connections: Regularly inspect all electrical connections for tightness and signs of wear or corrosion.
- Professional Service: For any internal component issues or complex repairs, consult a qualified professional or FDIK customer support.
8. Troubleshooting
This section provides a guide to common fault codes and their workarounds. For more detailed troubleshooting, refer to the official PDF manual.

| Fault Code | Cause | Workaround |
|---|---|---|
| E-2 | Supply voltage range | Normal range: 24V (18-32V), 12V (9-16V). Check whether the battery or generator is normal and whether the fuse is aging. |
| E-3 | Glow plug failure | Check whether the ignition plug connector is loose or the wire is short-circuited to the housing. Check whether the ignition plug is damaged. |
| E-4 | Oil pump failure | Check whether the oil pump connecting wires and connectors are damaged, loose, oxidized, short-circuited, or open-circuited. |
| E-5 | High temperature alarm (intake air >50°C; housing >230°C) | Check whether the heating air duct is unobstructed. Check whether the fan is operating normally. Check whether the temperature sensor is normal. |
| E-6 | Fan failure | Check if the impeller is stuck. Check whether the connection plug is loose. Is the gap between the magnet on the wind wheel and the Hall sensor on the controller too large? Is the circuit short-circuited or open-circuited; Is the motor leaking electricity? |
| E-7 | Connection failed | Detection harness. |
| E-8 | Lack of oil | Check whether there is oil shortage, oil solidification at low temperature, oil line blockage, oil pump stuck, etc. Check whether the oxygen inlet and exhaust pipes are unobstructed. Check whether the shell temperature sensor is in full contact with the shell and whether the pressure spring is firm. |
| E-9 | Sensor failure | Check whether the temperature sensor connection line or connector is damaged or loose, and whether the sensor is damaged. |
| E-10 | Startup failure | The casing temperature is too high and the casing cannot cool down after 3 minutes of startup. A lot of white smoke comes out of the exhaust gas. There is a small amount of white smoke or no smoke in the exhaust gas. Check whether the ignition plug is damaged. Is the gap between the inner wind wheels too large? |
9. User Tips
- Thermostat Function: The heater's temperature mode includes a start-stop function. It will turn off once the set temperature is reached and turn back on to maintain it.
- Power Supply Check: Always ensure your power source (12V, 24V, or 220V adapter) is stable and within the specified voltage range to prevent operational issues.
- Airflow is Key: For optimal heating and to prevent overheating, regularly check that the air intake and hot air ducts are completely unobstructed.
- Fuel Quality: Use high-quality diesel fuel to ensure efficient combustion and prevent fuel system issues.
10. Warranty and Support
10.1. Warranty Information
The FDIK T7 Diesel Air Heater comes with a one-year warranty. Please note that vulnerable parts are typically not included under warranty. Keep your purchase records for warranty claims.

10.2. Customer Support
For any questions, technical assistance, or support, please contact FDIK customer service. You can reach them via WhatsApp at +86 15935111083.
10.3. Additional Resources
A detailed user manual in PDF format is available for download. You can access it here: FDIK T7 User Manual (PDF).