CEM DT-1317

Contents

CEM DT-1317 Solar Irradiance Meter

User Manual

1. Introduction

The CEM DT-1317 Solar Irradiance Meter is a high-accuracy tool designed to simplify the installation, commissioning, and troubleshooting of photovoltaic (PV) arrays. This single handheld instrument measures solar irradiance, temperature, inclination, and direction of solar arrays. Its rugged, compact design and high-contrast LCD screen ensure easy readability even in direct sunlight.

This meter is essential for:

  • Installing, commissioning, and troubleshooting photovoltaic (PV) arrays.
  • Testing, documenting, and maintaining photovoltaic systems.
  • Measuring irradiance, temperature, inclination, and direction of solar arrays.
Application Scenario Diagram for CEM DT-1317 Solar Irradiance Meter

Image: The CEM DT-1317 Solar Irradiance Meter being used in various application scenarios, including installation, daily operation, and performance testing of solar energy systems.

2. Key Features

  • Sunlight Measurement: Irradiance measurements up to 1400 W/m².
  • Temperature Measurement: Utilizes a built-in temperature sensor or an external suction mount temperature probe for ambient and panel temperature readings.
  • Compass Function: Measures roof or site orientation (0° to 360°).
  • Tilt Angle Measurement: Measures inclination from -90° to 90°, providing insights into roof and PV panel tilt.
  • High Contrast LCD: Large numbers for easy readability in direct sunlight.
  • High Accuracy and Rapid Response: Ensures reliable and quick measurements.
  • Data Hold Function: Allows users to freeze and review measurement values.
Man using CEM DT-1317 Solar Irradiance Meter near solar panels

Image: A man holding the CEM DT-1317 Solar Irradiance Meter while standing near solar panels, illustrating its use for solar irradiance, temperature, compass, and tilt angle measurements.

3. Package Contents

Upon opening the package, please verify that all items listed below are present and in good condition:

  • CEM DT-1317 Solar Irradiance Meter (Main Unit)
  • External Temperature Probe
  • Carrying Case
Contents of the CEM DT-1317 Solar Irradiance Meter package

Image: The CEM DT-1317 Solar Irradiance Meter, its external temperature probe, and a carrying case, displayed next to the product box.

4. Product Overview

Familiarize yourself with the components and display elements of the DT-1317 Solar Irradiance Meter.

4.1 Meter Components

Panel Functions diagram of CEM DT-1317 Solar Irradiance Meter

Image: Detailed diagram of the CEM DT-1317 Solar Irradiance Meter and its external probe, labeling the Light Irradiance Sensor, various buttons (C/F, HOLD, ZERO, Power, Backlight), and the external temperature probe slot. Dimensions are also indicated.

  • Light Irradiance Sensor: Located at the top of the main unit.
  • External Temperature Probe Slot: For connecting the external temperature probe.
  • Buttons:
    • °C/°F: Toggles between Celsius and Fahrenheit temperature units.
    • HOLD: Freezes the current measurement on the display.
    • ZERO: Resets the tilt angle measurement.
    • Power Button (Red): Turns the device on/off.
    • Backlight Key (Sun icon): Activates/deactivates the display backlight.
    • Angle Reset (Triangle icon): Resets the tilt angle.

4.2 LCD Display Elements

  • HOLD: Indicates data hold function is active.
  • Low Battery Indicator: Appears when battery power is low.
  • W/m²: Unit for solar irradiance.
  • Compass Icon: Displays direction.
  • °C/°F: Temperature unit indicator.
  • Tilt Angle Measurement: Displays the measured inclination.
  • Zero: Indicates the zero reference for tilt angle.
  • Probe: Indicates external probe is in use.
  • Tester: Main unit display.
Close-up of CEM DT-1317 Solar Power Meter display

Image: A close-up view of the CEM DT-1317 Solar Power Meter's LCD display, showing irradiance (W/m²) and temperature (°C) readings, along with icons for HOLD, low battery, and compass.

5. Setup

5.1 Battery Installation

The DT-1317 Solar Irradiance Meter requires batteries for operation. Please note that batteries are not included in the standard package due to international shipping regulations. Purchase appropriate batteries from your local store or supermarket.

To install batteries:

  1. Locate the battery compartment cover on the back of the meter.
  2. Open the cover.
  3. Insert the batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

5.2 Connecting the External Temperature Probe

If you intend to use the external temperature probe for panel temperature measurements:

  1. Locate the external temperature probe slot on the side of the main unit.
  2. Carefully insert the probe connector into the slot until it clicks into place.
  3. Ensure the probe is securely attached before use.
Detail display of CEM DT-1317 showing internal sensor and external probe slot

Image: A detailed view of the CEM DT-1317, highlighting the internal temperature sensor and the external temperature probe slot, along with an example of the meter in use with the probe attached to a solar panel.

6. Operating Instructions

6.1 Power On/Off

  • Press the red power button to turn the meter ON.
  • Press and hold the red power button to turn the meter OFF.

6.2 Solar Irradiance Measurement

  1. Turn on the meter.
  2. Point the light irradiance sensor directly towards the sun or the solar panel surface you wish to measure.
  3. The solar irradiance value in W/m² will be displayed on the LCD.

6.3 Temperature Measurement

  • The meter automatically displays temperature using its built-in sensor.
  • If the external probe is connected, the display will show the temperature measured by the probe.
  • Press the °C/°F button to switch between Celsius and Fahrenheit units.

6.4 Compass Function

  • The compass icon and reading on the LCD indicate the orientation of the meter.
  • Hold the meter level and rotate it to determine the desired direction.

6.5 Tilt Angle Measurement

  1. Place the meter on the surface whose tilt you want to measure (e.g., a solar panel).
  2. The tilt angle will be displayed on the LCD.
  3. To set a new zero reference for relative angle measurements, press the ZERO button.
  4. To reset the angle measurement to absolute, press the Angle Reset button.

6.6 Data Hold

  • Press the HOLD button to freeze the current reading on the display. The 'HOLD' icon will appear.
  • Press the HOLD button again to release the data hold function and resume live readings.

6.7 Backlight

  • Press the Backlight Key (sun icon) to turn the LCD backlight on or off for better visibility in low-light conditions.

6.8 Auto Shutdown

The meter features an auto-shutdown function to conserve battery life. It will automatically power off after a period of inactivity. Press the power button to restart the device.

7. Maintenance

7.1 Cleaning

  • Wipe the meter's exterior with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents.
  • Keep the light irradiance sensor clean and free from dust or obstructions for accurate readings.

7.2 Storage

  • When not in use, store the meter in its carrying case to protect it from dust, moisture, and physical damage.
  • Remove batteries if the device will not be used for an extended period to prevent leakage.

7.3 Battery Replacement

  • Replace batteries when the low battery indicator appears on the LCD.
  • Refer to section 5.1 for battery installation instructions.

8. Troubleshooting

ProblemPossible CauseSolution
Meter does not power onDead or incorrectly installed batteriesCheck battery polarity, replace with fresh batteries.
Inaccurate irradiance readingsDirty sensor, obstruction, low batteryClean the light irradiance sensor. Ensure no obstructions. Replace batteries if low.
Temperature probe not workingLoose connection, faulty probeEnsure the external probe is securely connected. If problem persists, contact support.
Display is dim or flickeringLow batteryReplace batteries.

9. Specifications

FunctionRangeResolutionAccuracy
Sunlight0 - 1400 W/m²1 W/m²±5%
Temperature-30°C to 100°C (-22°F to 212°F)0.1°C (0.2°F)±1°C (±2°F)
Temperature measurement response time: 30s
Inclination-90° to 90°0.1°±1.5° - ±3.5°
Compass0° to 360°1°±7°
Data Metrics table for CEM DT-1317 Solar Irradiance Meter

Image: A table summarizing the data metrics for Irradiance, Temperature, and Tilt Angle, including measurement ranges and the compass function.

9.1 Physical Characteristics

  • Main Unit Dimensions: Approximately 17.5 cm (H) x 5.3 cm (W) x 3.5 cm (D)
  • Probe Dimensions: Approximately 17.5 cm (H) x 4.2 cm (W) x 2.8 cm (D)
  • Weight (packaged): Approximately 1.5 kg

10. User Tips

  • Battery Readiness: Remember that batteries are not included in the package. Please purchase the required batteries from a local store before first use.
  • Color Variation: The instrument may be delivered in either black or blue color. There is no functional difference between the colors.
  • Sensor Care: Always ensure the light irradiance sensor is clean and unobstructed for the most accurate readings.
  • Probe Placement: For accurate panel temperature measurements, ensure the external probe is in good contact with the panel surface.

11. Warranty and Support

CEM provides a warranty for its products against defects in materials and workmanship. If you encounter any issues with your DT-1317 Solar Irradiance Meter, please follow these guidelines:

  • Reporting Defects: Defective items must be reported and returned within the specified warranty period.
  • Original Packaging: Ensure the product is returned in its original packaging.
  • Required Information: When reporting a defect, please provide a clear description of the issue and your purchase ID.
  • Contact Support: For warranty claims, technical assistance, or any questions regarding the product, please contact the seller or CEM customer support directly.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.