FDIK HE-1 Pro

Contents

FDIK 12V 5KW Diesel Water Heater with LCD Control

Model: HE-1 Pro

Brand: FDIK

1. Introduction

Thank you for choosing our products! Please read this manual carefully before installation and follow the requirements. This manual will explain the working principle and process of the pre-heater, as well as the installation method and precautions.

An automotive fuel preheater is a product that combines a series of technical means such as precision casting, precision welding, precision machining, automatic control, and combustion engineering. Therefore, professional installation and maintenance are required for this device.

Diagram showing how the FDIK diesel water heater works within a vehicle's cooling system.
Figure 1: How the FDIK Diesel Water Heater Works. The heater ignites a fuel-air mix, heating cold coolant water. A circulation pump moves the heated water to the vehicle's heat exchanger. Once a specific temperature (approx. 80°C) is reached, the heater shuts off, but the circulation pump continues to run to maintain interior heating.

2. Specifications

The following table outlines the key specifications for the FDIK HE-1 Pro Diesel Water Heater:

AttributeSpecification (HE-1 Pro)
Heater ModelHE-1 Pro
Structure TypeFuel type water heating type heater
Max. Heating Power6.0 KW
Min. Heating Power2.8 KW
Max. Oil Consumption (+/- 10%)0.62 L/H
Min. Oil Consumption (+/- 10%)0.30 L/H
Rated Voltage12.4 V
Operating Voltage Range11.5 V - 16 V
Rated Voltage Consumption (without circulation pump and on-board fan)Max. 33 W, Min. 15 W
Work Temperature Range-40°C to +80°C
Dimensions (Length x Width x Height)210 × 91 × 147 mm
Weight6.5 kg
Special FeaturesAir heating
TypeCombustion Type Heater
Internal diagram of the FDIK heater showing water, air, and oil inlets/outlets.
Figure 2: Internal View and Flow Paths. This diagram illustrates the water inlet, water outlet, air inlet, air outlet, and oil inlet for the heater.

3. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your FDIK diesel water heater. Please follow these guidelines carefully.

3.1 General Installation Guidelines

  1. The preheater generates high temperatures; do not install it near brake fluid pipes or other devices sensitive to heat.
  2. The preheater requires heat radiation to the outside for proper internal temperature. Avoid installing it near the engine's exhaust pipe.
  3. The highest installation position of the preheater should be at least 10 cm lower than the vehicle's antifreeze filling surface.
  4. The lowest installation position of the preheater should be at least 10 cm above the vehicle's wading surface.
  5. The installation angle includes horizontal (intake and exhaust port facing the ground) and vertical orientations. Other installation methods may cause the heater to malfunction.
  6. Preferably install the preheater between the wheel cover and the front bumper, as low as possible, to ensure reliable venting for both the preheater and the circulation pump.
  7. The plug side of the preheater harness must not face upwards to prevent damage from brushing or water ingress.
  8. The heater is best installed in the engine compartment, within the waterproof splash protection area of the front mudguard, or on the mudguard itself. Install it at the lowest possible position to ensure automatic filling of coolant in both the heater and the water pump.
Diagram showing acceptable installation angles for the heater, between 0 and 90 degrees.
Figure 3: Heater Installation Angle Guidelines. The heater must be installed within the specified 0-90 degree range relative to the horizontal plane for proper operation.

Important Note:

  • In any installation scenario, the inlet and outlet of the heater must not face downward.
  • The heater must never be installed in proximity above high-temperature components within the vehicle or within the direct splash zone of the vehicle's wheels.

3.2 Circulating Water Circuit Installation

  1. We recommend installing the heater in the middle of the engine's outlet and the car heater heat exchanger.
  2. The water flow direction should be: Engine outlet → pre-heater water pump inlet (central axis) → pre-heater water pump outlet (tangential direction) → pre-heater cooling water inlet (marked "in") → pre-heater cooling water outlet (marked "out") → heater heat exchanger in the car.
  3. The circulating water pump should be installed in a position lower than the pre-heater.
  4. Fasten the water pipe joint with the pipe clamp provided in the accessory package.
  5. The water pump should be bolted securely to the car body. Overhanging installation can lead to wire breakage and water pipe leakage.
  6. Do not extend the water pump wiring harness. The distance between the water pump and the host is precisely specified; extending the harness may lead to pre-heater failure.
  7. Pay attention to antifreeze loss during installation. Replenish with the same specification of antifreeze after installation and refill to the specified capacity after a certain period of engine operation.
  8. Install the water pump at least 30 cm below the antifreeze level to prevent air from entering the pipeline, which can cause overheating and trigger fault codes.
Diagram illustrating the correct water pump and water connection method.
Figure 4: Water Pump and Water Connection Method. Ensure the water pump's water mouth end does not face down to prevent air retention and circulation issues.

3.3 Excluding Gas from the Circulating Water

  1. After installing all parts, start the car and run it at a high RPM for a period to eliminate gas from the circulating water circuit. Remember to replenish the antifreeze.
  2. If gas is not evacuated from the line, it will lead to a high-temperature alarm from the heater.

3.4 Oil Line Installation

Note: Before initially using the heater or after replacing the coolant, it is imperative to ensure that the coolant in the circulation system is fully topped up. Insufficient coolant may lead to overheating and trigger fault codes, resulting in the heater malfunctioning and shutting down during operation.

  1. Open the tank cover to relieve pressure, then remove the tank float and install the oil picker (from the accessory package). Exercise fire prevention during fuel tank removal.
  2. The fuel extractor should be positioned 5 cm above the bottom of the fuel tank to prevent running out of fuel and inability to start the car.
  3. For vehicles with irregular fuel tank bottoms, bend the fuel pickup tube appropriately to fit the tank.
  4. Install the fuel pump near the fuel tank. The plug side of the fuel pump is the outlet.
  5. The fuel pipe must not pass inside the vehicle cabin. It is recommended to lay it alongside the original fuel pipe and secure it with nylon ties (provided in the accessory package) every 15 cm.
  6. The fuel line must not be laid through heat-generating parts (e.g., exhaust port, silencer, air conditioning pump).
  7. Apply the rubber hose (from the accessory package) to connect the fuel line and fasten it with a hose clamp. The two fuel pipes inside the rubber hose should be closely connected, and the fuel pump should be bolted to the car body.
Diagram showing preferred installation angles for the fuel pump and tee connection.
Figure 5: Fuel Pump and Tee Installation Angles. The fuel pump's installation angle is preferred to be within the 1 and 2 zones shown. The tee connection must also comply with the specified installation angles.
Diagram illustrating correct and incorrect fuel pipe butt connections to prevent air bubbles.
Figure 6: Fuel Pipe Butt Connection. The fuel pipe butt must be contacted on both ends. If a turn is needed, there must be no downward bend to avoid collecting air bubbles.

3.5 Intake and Exhaust Installation

  1. The preheater is equipped with a protective shield at the air inlet. To ensure proper combustion air intake, the air inlet must not face the direction of vehicle travel.
  2. The air inlet should be well ventilated.
  3. The exhaust pipe temperature can reach 300°C. Avoid installing it near plastic parts or other components sensitive to high temperatures.
  4. The exhaust pipe must face downward to the ground, and its mouth must not be lower than the engine guard.
  5. Use pipe clamps to fasten the exhaust pipe and pre-heater interface. Apply appropriate tightening force to avoid deformation of the exhaust pipe and air leakage at the interface.
  6. The exhaust pipe can be bent at various angles to suit the installation.
  7. The length of the exhaust pipe is specially designed; do not change its length or omit its installation.
  8. The end of the exhaust pipe should be fixed to the car body using the pipe clamps and brackets provided in the accessory package.

3.6 Wiring Harness Laying

  1. Plug in the wiring harness according to the labels, matching colors.
  2. No extension of any connecting wire is allowed.
  3. Fuses must be replaced according to the same specifications. Using larger-sized fuses is prohibited.
  4. Avoid exposing the wiring harness to high-temperature radiation.
  5. Fasten the wiring harness with nylon ties (provided in the accessory package) to prevent wear and tear caused by vibration.

Wiring Instructions Table

ColorSignalDescription
RedPower positiveWorking voltage 10-30V
BrownNegative power supplyGND
OrangeMain board power signalMain board power signal line
YellowCommunication lineK-line communication
BlackSwitch indicator groundGND
GraySwitch signal lineControl switch signal
GreenSwitch indicator line5V indicator power
Image showing all components included in the FDIK heater kit.
Figure 7: Included Components. This image displays the main unit, LCD controller, remote, silencer, oil pump, water pump, air filter, wire harness, pipe, hose, oil pump clamp, screw accessories kit, exhaust pipe, and fixed plate.

4. Operating Instructions

Your FDIK diesel water heater is controlled via an LCD panel and remote control. Familiarize yourself with the buttons and functions below.

Image of the LCD control panel and remote control for the heater.
Figure 8: LCD Control Panel and Remote Control.

4.1 Button Description (LCD Control Panel)

  • Up Arrow (↑): Increases output power or parameter value.
  • Power Button (⏻): Short press to turn ON, long press to turn OFF.
  • Down Arrow (↓): Reduces output power or parameter value.
  • OK Button (OK): Enters parameter setting state, changes plumbing working parameters, checks running parameters, sets status, and confirms running parameters.

4.2 Special Function Keys

  • Remote Control Pairing: In shutdown mode, long press the Up Arrow (↑) button to enter remote control pairing mode.
  • Switch Time Mode / Gear Mode: Short press both Up Arrow (↑) and Down Arrow (↓) buttons simultaneously.
  • Manual Fuel Filling Mode: Briefly press both Down Arrow (↓) and OK buttons simultaneously.
  • Manually Turn On Pump (in shutdown): Long press the Power Button (⏻).

4.3 Check Machine Status

Short press the OK button to cycle through and display the following states:

  1. Water temperature display
  2. Ambient temperature display
  3. Gear display (gear mode) / Remaining time (time mode)
  4. Power supply voltage display

4.4 Manual Fuel Filling

This procedure is used to prime the fuel system, especially after initial installation or if the fuel line has run dry.

  1. In the shutdown state, press and hold the Down Arrow (↓) and OK buttons simultaneously to enter manual fuel injection mode. The display will show "OF".
  2. Release the buttons, then press the Up Arrow (↑) button. The display will show "on", and the oil pump will start working. You should hear the working sound of the oil pump, and the oil pump icon will light up.
  3. Observe the fuel line for air bubbles. Once the oil reaches the oil inlet position of the machine and air is purged, press the Down Arrow (↓) button. The display will show "OF", exiting the fuel injection mode, and the oil pump icon will disappear.
  4. Caution: If too much fuel enters the machine during this process, it may result in black smoke upon ignition.

4.5 Manual Separate Switching Pump

This function allows you to control the pump independently.

  1. In the shutdown state, long press the Power Button (⏻) to enter the pump control interface. The display will show "P OF".
  2. Press the Up Arrow (↑) button. The display will show "P on", indicating the pump is active.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your FDIK diesel water heater.

  • Coolant Level Check: Regularly inspect the coolant level in your vehicle's system and replenish as needed. Insufficient coolant can lead to overheating and fault codes.
  • Air Bleeding: Periodically check for and exclude any gas (air bubbles) from the circulating water system. Air in the system can cause high-temperature alarms and reduce heating efficiency.
  • Fuel Line Inspection: Visually inspect all fuel lines for any signs of wear, cracks, or leaks. Ensure all connections are secure and free from downward bends that could trap air.
  • Wiring Harness Inspection: Check the wiring harness for any signs of wear, fraying, or damage. Ensure all connections are tight and the harness is secured to prevent vibration damage.
  • Fuse Replacement: If a fuse blows, replace it only with a fuse of the exact same specification. Never use a fuse with a higher rating.
  • Combustion Chamber: The FDIK combustion chamber uses a brand-new casting process with high-quality 310S material, designed for durability. Regular inspection by a professional is recommended to ensure optimal performance.
  • Water Pump: The FDIK water pump has a pump water volume of up to 23L/min and a head of 2.5m. Ensure it is securely bolted and free from leaks.
Diagram showing the combustion chamber and water pump components.
Figure 9: Combustion Chamber and Water Pump Details. The combustion chamber is made of high-quality 310S material. The water pump ensures normal circulation and heating.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your FDIK diesel water heater. For complex problems or if you are unsure, please consult a professional.

Common Issues and Solutions:

  • High Temperature Alarm:
    • Cause: Gas (air bubbles) in the circulating water system.
    • Solution: Perform the "Excluding Gas from the Circulating Water" procedure (Section 3.3).
    • Cause: Insufficient coolant in the circulation system.
    • Solution: Check coolant level and replenish as necessary (refer to Section 3.2 and the important note in Section 3.4).
  • Heater Not Working Properly / Malfunction:
    • Cause: Incorrect installation angle of the main heater unit.
    • Solution: Ensure the heater is installed according to the guidelines in Section 3.1, particularly regarding horizontal or vertical orientation.
  • Wire Breakage or Water Pipe Leakage:
    • Cause: Overhanging installation of the water pump.
    • Solution: Ensure the water pump is securely bolted to the car body and not left hanging (Section 3.2).
  • Black Smoke on Ignition:
    • Cause: Too much fuel entered the combustion chamber during manual fuel filling.
    • Solution: Be careful during the manual fuel filling process (Section 4.4) to stop once oil reaches the inlet and air is purged.
  • Heater Does Not Start / No Power:
    • Cause: Incorrect wiring or blown fuse.
    • Solution: Check all wiring connections against the Wiring Instructions Table (Section 3.6). Inspect fuses and replace with the correct specification if blown.
  • No Heat Output:
    • Cause: Fuel supply issue (e.g., empty tank, clogged filter, faulty fuel pump).
    • Solution: Check fuel level, inspect fuel lines, and ensure the fuel pump is operating correctly. Perform manual fuel filling if necessary.

Fault Codes

The LCD control panel may display fault codes to indicate specific issues. While a detailed list of fault codes is not provided in this manual, if a code appears, note it down and refer to the comprehensive user manual PDF for specific diagnostics. You can find the PDF at this link.

7. User Tips

Here are some helpful tips based on common user inquiries and experiences:

  • Remote Control Range: The effective range of the remote control can vary depending on environmental factors and obstructions. Test the range in an open area to understand its limitations for your specific installation.
  • Temperature Adjustment: Yes, the temperature is adjustable via the LCD control panel, allowing you to set your desired heating level.
  • Fuel Type: This is a diesel parking heater. It cannot be powered by gasoline. Ensure you use the correct fuel type for proper operation and to prevent damage.
  • Complete Kit: The product typically includes the main heater unit, LCD controller, remote control, silencer, oil pump, water pump, air filter, wire harness, various pipes and hoses, an oil pump clamp, a screw accessories kit, an exhaust pipe, and a fixed plate. Always verify the contents upon receipt.
  • Coolant and Air: Always prioritize proper coolant filling and thorough air bleeding from the system. This is the most common cause of heating issues and alarms.
  • Professional Installation: Given the complexity and safety aspects of installing a fuel-burning device in a vehicle, professional installation is highly recommended.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided at the time of purchase or contact your seller directly. It is recommended to keep your purchase receipt and product model information handy when seeking support.

A comprehensive user manual in PDF format, which may contain additional details including a full list of fault codes, is available for download: FDIK 12V 5KW Water Heater User Manual (PDF).

© FDIK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.