1. Introduction
The Daly Black Smart BMS (Battery Management System) Y Series is an advanced protection board designed for 7-17S Li-ion, LiFePO4, and LTO battery packs. It features automatic string identification, built-in Bluetooth, and UART communication for smart monitoring and control via a dedicated mobile application. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Smart BMS.
2. Safety Information
Please read and understand all safety precautions before installing or operating the BMS. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always wear appropriate personal protective equipment (PPE) when working with batteries.
- Ensure the battery pack is disconnected from any power source before installation or maintenance.
- Do not short-circuit the battery terminals or BMS connections.
- Verify correct polarity for all connections. Incorrect wiring can damage the BMS and battery.
- Keep the BMS away from water, moisture, and flammable materials.
- Do not attempt to open or repair the BMS. Refer to qualified personnel for service.
- Ensure proper ventilation around the battery pack and BMS.
3. Package Contents
Upon opening your package, please verify that all components are present:
- Daly Black Smart BMS Unit
- Sampling Cable (Balance Wires)
- NTC Temperature Sensor
- Communication Cable (Red)
- Power Cable (White)

4. Specifications
The Daly Black Smart BMS Y Series is available in various current ratings and models. Please refer to the table below for detailed specifications:

| Attribute | Value |
|---|---|
| Voltage Range | Low voltage non-USB (below 75V DC, below 50V AC) |
| Electronic | No |
| Charger Included | No |
| Battery Included | No |
| High-concerned chemical | None |
| Accessory Type | Battery Accessories |
| Certification | CE |
| Origin | Mainland China |
| Apply to Battery Type | LiFePo4/Li-ion/LTO |
| Charging/Discharging port | Common Port |
| Battery Strings | 7S-17S (also supports 4-8S, 7-24S depending on model) |
| Balance Current | Passive balance |
| Charge/Discharge Current | 30-200A (model dependent) |
| Communication | UART/Built-in BT |
| Working Power Consumption | ≤10mA |
| Sleeping Current | <600uA |
Note: Dimensional data tolerance range ±0.5mm. Features and data are based on DALY lab tests and are for reference only.
5. Installation Guide
Follow these steps carefully to install your Daly Black Smart BMS. Ensure the battery pack is completely disconnected before starting.
5.1. Wiring Diagrams
Refer to the appropriate wiring diagram for your battery configuration (e.g., 4-8S, 7-17S, 7-24S). The YK BMS is used as an example, and other specifications follow similar wiring principles.


5.2. Step-by-Step Installation
- Weld Sampling Cable: Start by welding the thin black wire of the sampling cable to B- (main negative) of the battery pack. Then, connect each cell's positive terminal in sequential order. The last red wire should be connected to B+ (main positive).
Note: Do NOT plug the sampling cable into the BMS during welding. Insulate any unused wires. - Check Voltages: Use a multimeter or wire tester to confirm that each cell's voltage is normal and consistent. Rectify any miswiring or poor soldering before proceeding.
- Weld Output Wires: Secure the B- and P- terminals to the BMS with a torque of 10N·m. Weld the B- wire to the battery negative terminal.
Note: Insulate the P- terminal before making the final connection. - Plug NTC and Sampling Cable: Insert the NTC temperature sensor into its designated port on the BMS. Then, plug the sampling cable into the BMS. This action will auto-activate the BMS.
5.3. Automatic String Identification
The BMS automatically identifies the number of battery strings (e.g., 4S, 8S, 10S, 12S, 17S, 20S, 24S) upon its first power-up. This feature simplifies setup by eliminating manual configuration of string count.

6. Operating Instructions
The Daly Black Smart BMS offers intelligent monitoring and control through its built-in Bluetooth and a dedicated mobile application.
6.1. Smart APP Functionality
The Smart BMS APP allows you to view and set various battery parameters, monitor real-time battery information such as voltage, current, charge/discharge status, and receive alerts. This provides comprehensive oversight of your battery pack's health and performance.

6.2. Communication and Expansion
The BMS supports multi-channel communication and offers various expansion options:
- Built-in Bluetooth: For wireless connection to the mobile APP.
- UART: For wired communication with PC Manager or other compatible devices.
- RS485 (Customized): Can be connected to inverters or EV controllers for advanced system integration.
- WiFi Module (Optional): Allows access to the DALY Cloud platform for remote management and firmware upgrades.
- Display Accessories: Compatible with various display units (e.g., 3-inch, 4.3-inch touch screen, circular power indicator) for local monitoring.


6.3. DALY Cloud Remote Management
With an optional WiFi module, you can connect your BMS to the DALY Cloud platform. This enables remote management of multiple Li-battery packs, storage of battery data in the cloud, and supports multi-level sub-accounts. Firmware upgrades can also be performed remotely via the APP and Cloud Platform.

7. Maintenance
- Regularly check all wiring connections for tightness and signs of corrosion.
- Monitor battery parameters via the Smart APP to identify any anomalies early.
- Keep the BMS clean and free from dust and debris.
- Ensure adequate airflow around the BMS to prevent overheating.
- Periodically check the NTC temperature sensor for proper placement and function.
8. Troubleshooting
If you encounter issues with your Daly Black Smart BMS, consider the following:
- No Power/BMS Not Activating: Double-check all wiring, especially the B- and B+ connections and the sampling cable. Ensure the sampling cable is fully inserted after welding.
- Incorrect Voltage Readings: Verify that the sampling wires are correctly connected to each cell's positive terminal in sequence. Use a multimeter to confirm individual cell voltages.
- Bluetooth Connection Issues: Ensure Bluetooth is enabled on your device and the BMS is within range. Restart the APP and try reconnecting.
- Over-current/Over-voltage/Under-voltage Alerts: Check your battery pack's health and load. The BMS is designed to protect the battery; these alerts indicate a potential issue with the battery or its usage. Refer to the Smart APP for specific alert details.
- BMS Overheating: Ensure proper ventilation. Check for excessive current draw or internal shorts in the battery pack.
For more detailed troubleshooting or persistent issues, please refer to the comprehensive user manual PDF or contact customer support.
9. Warranty and Support
For detailed warranty information and technical support, please refer to the official Daly documentation. A comprehensive user manual in PDF format is available for download, which provides in-depth information on advanced features, detailed wiring diagrams, and troubleshooting steps.
User Manual (PDF): A detailed user manual is available in PDF format. Please refer to the seller's product page or contact customer support for access to this document.