PORTXVNSA NanoVNA-H4 Plus

Contents

PORTXVNSA NanoVNA-H4 Plus User Manual

Handheld Vector Network Analyzer (50KHz - 2.7GHz)

1. Introduction

The PORTXVNSA NanoVNA-H4 Plus is an upgraded handheld Vector Network Analyzer designed for HAM radio and RF electronics hobbyists. It features a 4-inch IPS LCD display, an extended measurement range from 50KHz to 2.7GHz, and an increased number of scanning points to 401. This device supports various measurements including SWR, impedance matching, dual-band and triple-band duplexers, port isolation, and insertion loss of filters. Its ergonomic design, resistive touch screen, and large knob ensure ease of use, while the built-in 5000mAh battery provides extended operation time.

PORTXVNSA NanoVNA-H4 Plus with accessories
Figure 1: The 2025 Upgraded NanoVNA-H4 Plus with its 4-inch IPS LCD display and included accessories.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present:

  • NanoVNA-H4 Plus Unit
  • USB Type-C Cable (for charging and data transfer)
  • Calibration Kit (OPEN, SHORT, LOAD)
  • SMA Male to Male Cable (x2)
  • Stylus Pen (for resistive touch screen)
  • Optional: 32GB Memory Card (if purchased with this option)
NanoVNA-H4 Plus and its accessories
Figure 2: Diagram showing the NanoVNA-H4 Plus and its standard accessories, including calibration kit, cables, and an optional 32GB memory card.

3. Specifications

Feature Specification
Bandwidth 50KHz - 2.7GHz
Dynamic Range 80dB (50KHz-900MHz), 60dB (900MHz-1.5GHz), 50dB (1.5GHz-2.7GHz)
Reflection Coefficient (SWR) <1.1
Frequency Accuracy <0.5 ppm
Frequency Stability <2.5 pp
Display 4-inch IPS LCD with resistive touch screen
Scanning Points 401
Battery 5000mAh Rechargeable Battery (Included)
PC Connectivity Type-C Port, PC Control via Nano Saver software
Data Storage SD Card support for Touchstone files
Certification CE
Origin Mainland China

4. Initial Setup

  1. Unpack: Carefully remove the NanoVNA-H4 Plus and all accessories from the packaging.
  2. Charge Battery: Connect the device to a 5V USB power source using the provided Type-C cable to fully charge the internal 5000mAh battery before first use.
  3. Insert SD Card (Optional): If you have an SD card (or purchased the 32GB option), insert it into the designated slot for storing measurement data.
  4. Power On: Press and hold the power button (usually located on the top or side) to turn on the device.
  5. Touch Screen Calibration: Upon first power-on or if touch response is inaccurate, perform a touch screen calibration. Navigate to the 'Config' menu, then 'Touch Test' or 'Calibration' and follow the on-screen prompts.
NanoVNA-H4 Plus resistive touch screen
Figure 3: The 4-inch IPS screen with resistive touch functionality for sensitive and fast interaction.

5. Operating Instructions

The NanoVNA-H4 Plus offers a user-friendly interface with both touch screen and a large rotary knob for navigation and parameter adjustment.

5.1 Basic Navigation

  • Rotary Knob: Turn to scroll through menu options or adjust values. Press to select an option or confirm a value.
  • Touch Screen: Tap on menu items or input fields for direct interaction.
  • Back Button: Typically found in the menu, or a dedicated button, to return to the previous screen.

5.2 Calibration

Accurate measurements require proper calibration. Always perform a calibration for the frequency range you intend to measure.

  1. From the main screen, press the rotary knob or tap the screen to open the menu.
  2. Navigate to 'CALIBRATE' and select it.
  3. Follow the on-screen instructions to connect the OPEN, SHORT, and LOAD calibration standards to the CH0 port as prompted.
  4. After completing the calibration steps, save the calibration data.

5.3 Performing Measurements

The NanoVNA-H4 Plus can perform various RF measurements:

  • Scanning Antenna Systems and Cables: Connect the antenna or cable to the CH0 port. Select the desired measurement type (e.g., S11 for reflection) and frequency range.
  • SWR and Impedance Matching: Display SWR and Smith Chart to analyze antenna performance and impedance.
  • Measuring Dual-band and Triple-band Duplexers: Use both CH0 and CH1 ports for through measurements (S21).
  • Port Isolation by Frequency Band: Measure isolation between ports.
  • Measuring Insertion Loss of Filters: Connect the filter between CH0 and CH1 and measure S21.
Various measurement applications of NanoVNA-H4 Plus
Figure 4: Examples of measurements including 2.4 GHz antenna, shortwave antennas, and cable length.

5.4 PC Control via Nano Saver

The device can be connected to a PC via its Type-C port for advanced control and data analysis using Nano Saver software. This multiplatform tool allows saving Touchstone files, sweeping frequency spans in segments, and displaying/analyzing data beyond the device's native capabilities.

NanoVNA-H4 Plus connected to PC via Type-C
Figure 5: The NanoVNA-H4 Plus connected to a laptop for PC control and data analysis using Nano Saver software.

5.5 Video Demonstration

Watch this video for a visual guide on navigating the user interface, performing touch screen calibration, and exploring various display modes.

Video 1: Demonstration of NanoVNA-H4 Plus user interface, menu navigation, and touch screen functionality.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. For stubborn dirt, a slightly damp cloth can be used, but ensure no moisture enters the ports or openings.
  • Storage: Store the NanoVNA-H4 Plus in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. If storing for extended periods, charge the battery to about 50-70%.
  • Connector Care: Keep the SMA connectors clean and free from dust or debris. Use protective caps when not in use.

7. Troubleshooting

Problem Possible Cause Solution
Device does not power on Low battery, faulty charging cable/adapter Charge the device for at least 30 minutes. Try a different Type-C cable and power adapter.
Inaccurate measurements Improper calibration, loose connections, interference Perform a full calibration for the desired frequency range. Ensure all connectors are tight. Check for nearby RF sources.
Touch screen unresponsive Needs calibration, software glitch Perform touch screen calibration (use the rotary knob to navigate to 'Config' -> 'Touch Test'). Restart the device.
Cannot save data to SD card SD card full, corrupted, or incompatible format Check SD card storage. Try formatting the SD card (FAT32 recommended). Try a different SD card.

8. User Tips

  • For optimal accuracy, always calibrate the device for the specific frequency range you are working within.
  • Utilize the large rotary knob for precise adjustments, especially when fine-tuning frequency or marker positions.
  • When analyzing complex RF circuits, consider using the PC control software (Nano Saver) for enhanced data visualization and analysis capabilities.
  • Keep the calibration standards (OPEN, SHORT, LOAD) in good condition and use them carefully to avoid damage, which can affect measurement accuracy.

9. Warranty and Support

This product comes with a standard manufacturer's warranty. For specific warranty terms, duration, and support inquiries, please refer to the documentation provided at the time of purchase or contact the seller directly. Ensure you retain your proof of purchase for warranty claims.

For technical assistance or further questions, please reach out to the customer support channel provided by your retailer or the manufacturer.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.