Mitutoyo 293-250-30 Series

Contents

Mitutoyo Digital Micrometer Instruction Manual

Models: 293-250-30, 293-251-30, 293-252-30, 293-253-30, 293-254-30, 293-255-30, 293-256-30, 293-257-30

Introduction

This manual provides essential instructions for the safe and effective use of your Mitutoyo Digital Outside Micrometer. Designed for precision measurement, these instruments offer high accuracy and digital readout for various industrial and workshop applications. Please read this manual thoroughly before using the micrometer to ensure proper operation and to maintain its accuracy and longevity.

Video: Overview of the Mitutoyo Digital Micrometer.

1. Setup

1.1 Unpacking

Carefully remove the micrometer and its accessories from the protective case. Inspect all components for any signs of damage during transit. The package typically includes the micrometer, a setting standard (for models with a measuring range over 25mm/1 inch), a battery, and this instruction manual.

Mitutoyo Digital Micrometer 293-250-30 (100-125mm) in its protective case with battery and setting rod.

Figure 1: Micrometer 293-250-30 (100-125mm) in its protective case.

Mitutoyo Digital Micrometer 293-251-30 (125-150mm) in a wooden protective case.

Figure 2: Micrometer 293-251-30 (125-150mm) in its wooden case.

1.2 Battery Installation

  1. Locate the battery compartment cover on the digital display unit.
  2. Using a small screwdriver or coin, gently open the cover.
  3. Insert the SR44W 1.55V battery (or equivalent) with the positive (+) side facing up.
  4. Close the battery compartment cover securely.

1.3 Initial Zero Setting

  1. Clean the measuring faces of the micrometer with a lint-free cloth.
  2. For micrometers with a range of 0-25mm (0-1 inch), slowly close the measuring faces until they meet. For larger micrometers, use the provided setting standard between the measuring faces.
  3. Engage the ratchet stop or friction thimble until a slight click is heard 2-3 times to ensure consistent measuring force.
  4. Press the 'ZERO/ABS' button. The display should show '0.000' (or '0.00' depending on resolution). If not, repeat the process.

2. Operating Instructions

2.1 Basic Measurement

  1. Ensure the micrometer is clean and properly zeroed.
  2. Open the measuring faces slightly wider than the object to be measured.
  3. Position the object between the anvil and spindle.
  4. Slowly close the measuring faces using the ratchet stop or friction thimble until the object is gently held and 2-3 clicks are heard. Avoid overtightening.
  5. Read the measurement directly from the digital display.

2.2 Function Buttons

  • ON/OFF: Powers the unit on or off.
  • ZERO/ABS: Sets the display to zero at any spindle position (incremental measurement) or switches between absolute (ABS) and incremental (INC) measurement modes. In ABS mode, the display shows the true distance from the origin point (usually the fully closed position).
  • HOLD: Freezes the current displayed measurement. Press again to release.
  • PRESET: Allows setting a desired starting value for the display. Useful for comparative measurements.

3. Maintenance

3.1 Cleaning

  • Regularly clean the measuring faces and body of the micrometer with a clean, dry, lint-free cloth.
  • Avoid using solvents or harsh chemicals, as these can damage the finish or electronic components.
  • Ensure no dust or debris accumulates on the measuring surfaces or inside the digital display area.

3.2 Storage

  • Always store the micrometer in its original protective case when not in use.
  • Store in a dry environment, away from direct sunlight, extreme temperatures, and high humidity.
  • When storing for extended periods, slightly open the measuring faces to prevent pressure on the spindle and anvil.

3.3 Battery Replacement

When the battery indicator appears on the display, replace the battery as described in Section 1.2. Dispose of old batteries according to local regulations.

4. Troubleshooting

ProblemPossible CauseSolution
Display does not turn onDead or incorrectly installed batteryReplace battery or re-install correctly.
Inaccurate readingsDirty measuring faces, improper zero setting, or excessive measuring forceClean faces, re-zero the micrometer, ensure consistent measuring force with ratchet stop.
Display shows 'E' or error codeSystem error or internal malfunctionTry removing and re-inserting the battery. If the error persists, contact support.

5. Specifications

FeatureDetail
Brand NameMitutoyo
Model Numbers293-250-30, 293-251-30, 293-252-30, 293-253-30, 293-254-30, 293-255-30, 293-256-30, 293-257-30
Micrometer TypeOutside Micrometers
Display TypeDIGITAL
Accuracy0.001mm
DIY SuppliesMetalworking
OriginJapan
Package Dimensions (approx.)Length: 35cm, Width: 16cm, Height: 12cm
Package Weight (approx.)1.5 kg

Measurement Ranges by Model:

  • 293-250-30: 100-125mm
  • 293-251-30: 125-150mm
  • 293-252-30: 150-175mm
  • 293-253-30: 175-200mm
  • 293-254-30: 200-225mm
  • 293-255-30: 225-250mm
  • 293-256-30: 250-275mm
  • 293-257-30: 275-300mm

6. User Tips

  • Temperature Stability: For highest accuracy, allow the micrometer and the object to be measured to stabilize at the same ambient temperature.
  • Consistent Force: Always use the ratchet stop or friction thimble to apply consistent measuring force. This is crucial for repeatable and accurate readings.
  • Regular Zero Check: Periodically check and re-zero the micrometer, especially before critical measurements or if the instrument has been handled roughly.
  • Avoid Dropping: Precision instruments are sensitive to impact. Always handle your micrometer with care to prevent damage and loss of calibration.
  • Cleanliness is Key: Dust, oil, or fingerprints on the measuring faces can significantly affect accuracy. Keep them meticulously clean.

7. Warranty and Support

For warranty information, technical support, or service, please refer to the documentation provided with your purchase or contact your authorized Mitutoyo dealer or the seller directly. Keep your purchase receipt as proof of purchase.