1. Introduction
This manual provides essential information for the safe and efficient operation of your JESVERTY Adjustable DC Power Supply. Please read this manual thoroughly before using the device and keep it for future reference.
The JESVERTY SPS-V series bench power supply features advanced coarse and fine encoder knobs for precise voltage and current adjustments, a 4-digit LED display, and convenient USB-A and USB-C 20W fast charging ports. It includes safety features like Over Current Protection (OCP) and an Output ON/OFF button for enhanced usability.
2. Product Overview
Familiarize yourself with the components and controls of your DC Power Supply.

- Voltage Display
- C.V. Mode Indicator (Constant Voltage)
- C.C. Mode Indicator (Constant Current)
- Current Display
- OCP Status LED (Over Current Protection)
- OPN Status LED (Output Power ON)
- Power Display
- USB-C Quick-Charge Port
- USB-A Quick-Charge Port
- OCP Setting Button
- Output Control Button
- Voltage Knob (Coarse Adjustment)
- Voltage Knob (Fine Adjustment)
- Current Knob (Coarse Adjustment)
- Current Knob (Fine Adjustment)
- Power Switch
- Output Terminal - (Black)
- Grounding Terminal (Green)
- Output Terminal + (Red)
- Cooling Fan
- Input Selectable Switch (AC115V/230V)
- AC Power Inlet
- Fuse Box (Spare Fuse Inside)
3. Specifications
| Feature | Description |
|---|---|
| Type | Power Supply |
| Rated Capacity | 40-1000VA (includes 40VA) |
| Model (SPS3010v) | 30V 10A 300W |
| Model (SPS6005v) | 60V 5A 300W |
| Display | 4-Digit LED Display (0.01V, 0.001A, 0.1W resolution) |
| USB Charging Ports | 1x USB-A (20W Fast Charge), 1x USB-C (20W Fast Charge) |
| Input Voltage | AC115V/230V (selectable) |
| Dimensions (approx.) | 18cm (D) x 9cm (W) x 16cm (H) / 7.1(D) x 3.6(W) x 6.2(H) inches |
| Weight (approx.) | 1.14kg / 2.5lbs |
| Cooling | Temperature-regulated cooling fan |
| Origin | Mainland China |

4. Setup Instructions
- **Unpacking**: Carefully remove the power supply and all accessories from the packaging. Verify that all items listed in the "What's in the box" section are present.
- **Power Connection**:
- Ensure the power supply is switched OFF (Power Switch, item 16 in Figure 1).
- Check the Input Selectable Switch (item 21 in Figure 1) on the rear panel and set it to match your local AC mains voltage (AC115V or AC230V).
- Connect the provided power cord to the AC Power Inlet (item 22 in Figure 1) on the rear panel and then to a suitable AC outlet.
- **Output Connection**:
- Connect your load to the Output Terminal + (Red) (item 19) and Output Terminal - (Black) (item 17) using appropriate test leads.
- For safety, connect the Grounding Terminal (Green) (item 18) to the ground of your setup if required.
- Note: The provided test leads are for general use. For long-term high current applications, use test leads with sufficient current capacity.
5. Operating Instructions
5.1 Basic Operation
- **Power On**: Press the POWER button (item 16) to turn on the power supply. The display will illuminate.
- **Voltage Adjustment**:
- Use the V-COARSE knob (item 12) to adjust the voltage digits before the decimal point.
- Use the V-FINE knob (item 13) to adjust the voltage digits after the decimal point.
- Press the knob to switch between the digits to be adjusted.
- **Current Adjustment**:
- Use the A-COARSE knob (item 14) to adjust the first two digits of the current display.
- Use the A-FINE knob (item 15) to adjust the last two digits of the current display.
- Press the knob to switch between the digits to be adjusted.
- **Output Control**:
- Press the OUT button (item 11) to turn the output ON or OFF.
- When the output is ON, the display will show the actual voltage, current, and power.

5.2 Over Current Protection (OCP)
The OCP function protects your load device from overcurrent.
- Press the OCP button (item 10) to enter the OCP function interface.
- Adjust the required OCP trip point using the voltage/current adjustment knobs.
- Turn the V-COARSE knob (item 12) to enable OCP (display changes from "0" to "1"). The OCP indicator (item 5) will light up.
- Press the OCP button (item 10) again to return to the main interface.
- When the output current exceeds the set OCP trip point, the OCP indicator will flash, and the output will automatically turn off to protect the load.

5.3 Output Power ON (OPN) Function
The OPN function allows the unit to output voltage and current automatically as soon as the power switch is turned on, without needing to press the "OUT" button.
- Press and hold the OUT button (item 11) for 3 seconds to enter the OPN configuration interface.
- Press the OUT button (item 11) again to enable OPN (display changes from "0" to "1"). The OPN indicator (item 6) will light up.
- Press and hold the OUT button (item 11) for 3 seconds again to return to the main interface.
- When OPN is enabled, restarting the power supply will immediately provide output.
5.4 USB Charging Function
The power supply includes 20W USB-A (item 9) and USB-C (item 8) fast charging ports.
- Connect your mobile phone or other compatible device to either the USB-A or USB-C port using a suitable charging cable.
- Both ports support multiple quick-charge protocols for fast charging.

6. Maintenance
- **Cleaning**: Disconnect the power supply from the mains before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- **Ventilation**: Ensure the Cooling Fan (item 20) and ventilation openings are clear of obstructions to prevent overheating. The fan is temperature-regulated and will activate as needed.
- **Fuse Replacement**: The fuse box (item 23) contains a spare fuse. If the unit does not power on, check and replace the fuse if necessary. Ensure to use a fuse of the correct rating.
- **Storage**: Store the power supply in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power/display | Power cord not connected, power switch off, incorrect input voltage setting, blown fuse. | Check power cord, ensure power switch is ON, verify AC115V/230V switch setting, check/replace fuse. |
| No output voltage/current | Output OFF, OCP activated, OPN not enabled (if desired). | Press the OUT button to turn output ON. Check OCP settings and reset if necessary. Enable OPN if automatic output is desired. |
| OCP indicator flashing, output off | Output current exceeded the set OCP limit. | Reduce load current or increase OCP trip point. Ensure load is within the power supply's capabilities. |
| Inaccurate voltage/current readings | Poor connection, faulty test leads, external interference. | Ensure secure connections. Use high-quality test leads. Minimize electromagnetic interference. |
8. User Tips
- **Precise Adjustment**: Utilize the coarse and fine adjustment knobs for both voltage and current to achieve highly accurate settings, especially for sensitive circuits.
- **Automatic Output (OPN)**: If you frequently need the power supply to start with output immediately upon power-on, enable the OPN function as described in section 5.3.
- **Test Lead Quality**: While the unit comes with test leads, consider investing in higher quality, thicker gauge test leads for applications involving high currents or long-term use to ensure minimal voltage drop and accurate readings.
- **Overcurrent Protection (OCP)**: Always set the OCP limit slightly above your expected operating current to protect your circuit from accidental overloads.
- **USB Charging**: The integrated USB-A and USB-C ports are excellent for conveniently charging mobile devices or powering small USB-powered projects directly from the power supply.
9. Warranty and Support
The JESVERTY Adjustable DC Power Supply comes with a One-Year Warranty.
For technical support, warranty claims, or any questions regarding your product, please contact Jesverty Customer Service. Contact information can be found on the back of your instruction manual or through the seller's platform.