Hcalory TC2-SE

Contents

Hcalory 8KW Diesel Heater TC2-SE User Manual

Model: TC2-SE | Brand: Hcalory

1. Introduction

1.1 Product Overview

Diesel heaters are on-board heating devices that are independent of the automobile engine, and have their own fuel lines, circuits, combustion heating devices, and control devices. Originally, the machine was often used to preheat the engine and cab of a car parked in a cold environment in winter, as a way to eliminate cold start wear and tear of the car. Now diesel heaters have a wider range of uses, which can be used as space heating equipment in tents, indoors, and RVs, making users living and traveling more comfortable.

1.2 Explanation of Principles (Heat Source, Heating, Control)

1.2.1 Heat Source

After the equipment is started, the ignition plug will continue to heat up (1-3 minutes). The fan then delivers air to the combustion chamber, and the diesel pump injects diesel. The atomized diesel mixes with air and burns upon contact with the high-temperature ignition plug, generating significant heat. High-temperature exhaust gases are discharged from the exhaust gas outlet below.

1.2.2 Heating

The heat generated in the combustion chamber is quickly transferred to the aluminum heat exchanger and dissipated into the warm air duct via aluminum fins. An external fan blows air around the heat exchanger, and the heated air is blown out of the warm air outlet.

1.2.3 Control

The controller is embedded in the device. Users can control the device through the switch panel, checking running status, controlling gear, and setting appointments. Remote control or the Hcalory app can also be used for remote control.

1.3 Internal Key Parts Terminology

The following diagram illustrates the internal components of the heater. Familiarize yourself with these parts before attempting any repairs.

Diagram of Hcalory diesel heater internal components including control box, ignition plug, air inlet, air outlet, combustion chamber, heating zone, air fan, flame retardant impeller, and safety plug.

Internal components of the Hcalory diesel heater.

2. Package Contents

Please check the package contents against the list below. If any items are missing or damaged, please contact customer support.

Diagram showing all included parts for the Hcalory diesel heater: Host, AC-DC power supply, wire harness, exhaust silencer, exhaust pipe, intake pipe, air outlet pipe, air filter, vents, manual, fixture accessories set, LCD switch, remote control, controller extension cord.

Included components of the Hcalory diesel heater.

  • 1 x Air Diesel Heater (Host)
  • 1 x Remote control
  • 1 x LCD Switch
  • 1 x Controller extension cord
  • 1 x AC-DC power supply (Optional purchase)
  • 1 x Wire harness
  • 1 x Exhaust Silencer
  • 1 x Exhaust pipe
  • 1 x Intake pipe
  • 1 x Air Outlet Pipe
  • 1 x Air Filter
  • 1 x Vents
  • 1 x User Manual (PDF available at Hcalory User Manual PDF)
  • 1 x Fixture Accessories set

3. Setup and Installation

The installation of this toolbox compact heater is simplified. You primarily need to install the exhaust pipe and connect the AC-DC power supply to begin operation. Ensure the exhaust pipe is extended outdoors to safely expel combustion gases.

3.1 Installation Steps

  1. Connect the Exhaust Hose: Connect the exhaust hose to the heater's exhaust port and secure it firmly with a locking collar.
  2. Attach Muffler: Attach the other end of the exhaust hose to the muffler and secure it with a locking collar.
  3. Connect Warm Air Hose: Connect the warm air hose to the heater's air outlet and secure it with a locking collar.
  4. Attach Vent Outlet: Attach the other end of the warm air hose to the vent outlet and secure it with a locking collar.
  5. Fill Fuel Tank: Open the top cover of the heater, unscrew the fuel tank cap, and fill the 5L tank with diesel fuel. Close the cap securely.
  6. Connect Power: Connect the power supply cord or adapter to the electricity source. Use a 12V or 24V DC power supply, or an AC to DC adapter. The discharge current should be greater than 15A (the device needs 12A for 3-5 minutes during glow plug heating).
  7. (Optional) Controller Extension: If needed, disconnect the screen's attached wire and connect an extension cable for remote placement of the control panel.

3.2 Installation Video Guide

Watch this video for a visual guide on the installation process:

Video demonstrating the installation steps for the Hcalory Toolbox Compact 2 S Diesel Heater.

3.3 Important Installation Notes

  • The discharged exhaust gas can reach temperatures as high as 400°C. Keep it away from pets, children, and ensure sufficient clearance from the ground to avoid damaging your floor or lawn.
  • Ensure all pipelines are unblocked and not squeezed or blocked to maintain heating efficiency and prevent overheating.

4. Operating Instructions

4.1 Control Panel Overview

Hcalory diesel heater control panel with labels for Add key, Power on/off key, Minus key, OK key, Altitude, Clock display, Display data and parameters, Power bar, and Host appearance.

LCD Control Panel with key functions and display areas.

4.2 Icon Meanings

IconMeaning
FanFan operation
Bluetooth symbolBluetooth connectivity
Fault promptIndicates an error or fault
Sensor failureTemperature sensor malfunction
Plateau statusAltitude mode active
Automatic start/stopAutomatic heating cycle enabled
Power failurePower supply issue
Timer alarmTimer function active
Ventilation statusVentilation mode active
Ignition plugIgnition plug status
Carbon monoxide alarmCarbon monoxide detection/alarm
Manual modeManual control mode
Fuel pumpFuel pump operation
High temperature alarmOverheating warning
Constant temperature modeConstant temperature control mode

4.3 Power On/Off Operation

  • Power-on: In the off state, press and hold the "Power" button for 2 seconds to turn on the device.
  • Shutdown: In the power-on state, press and hold the "Power" button for 2 seconds. The device will enter the shutdown and cooling process, and the display will show "OFF". The device will shut down after cooling.

Important: Do not force the power off when it displays "OFF". Forcing power off can damage accessories due to high internal temperatures. Wait until the machine displays "OFF" before disconnecting power.

4.4 Manual Mode Operation

Manual mode has 10 gears (H1-H10), where H10 is maximum power. Press the "+" or "-" key to increase/decrease the gear. The display will show the current gear.

4.5 Constant Temperature Mode Operation

In constant temperature mode, press the "+" or "-" key to increase or decrease the temperature value. The setting range is 0 to 40 °C. Press and hold the "Settings" button for 2 seconds to switch between manual and constant temperature mode.

4.6 Automatic Start-Stop Operation

In constant temperature mode, short press the "Power" key to activate automatic start/stop (icon "A" displayed). Short press again to deactivate. Default power-on is -4°C, power-off is +3°C. For example, if set to 24°C, it shuts down at 27°C and starts at 20°C. These values can be changed via the mobile app.

4.7 Ventilation Operation

In the off state, press and hold the "Settings" key for 2 seconds to enter ventilation mode. The display will show the fan icon. Press "+" or "-" to adjust fan speed. Press and hold "Settings" for 2 seconds to exit ventilation mode.

4.8 Switch Display Data

In the power-on state, short press the "OK" button to cycle through displayed data: case temperature → working voltage → ambient temperature → carbon monoxide concentration → current gear (or current set temperature).

4.9 Temperature Unit Switching

Press and hold the "Settings" and "+" keys for 2 seconds simultaneously to switch between °C and °F.

4.10 Manual Oiling Operation

In the off state, press the "+" and "-" keys for 2 seconds simultaneously to manually control the oil pump. Release the keys to stop oiling. Use with caution.

4.11 Altitude Enabling Operation

Press and hold the "Settings" and "OK" keys for 2 seconds simultaneously to activate plateau mode (icon "*" displayed). This adjusts the air-oil ratio for high altitudes. Press and hold again to deactivate. It is recommended for use between 2000-5000 meters above sea level. Prolonged use above 4000 meters without spare parts is not recommended due to complex environmental factors.

4.12 Scheduled On/Off Operation

Press and hold "OK" and "+" for 2 seconds to enter timer settings. If no timer is set, you can set one. The indicator symbol "H" will be displayed. "CLOS" sets shutdown time, "OPEN" sets startup time. Use "+" or "-" to adjust time (00:00-23:59). Use "Settings" to switch digits. Press "OK" to save. If no key is pressed for 10 seconds, settings are saved and the interface exits. Press "Power" to exit without saving. The "L" symbol flashes when timing is active. The machine will automatically turn on/off at scheduled times. Press "Settings" to view all set times.

4.13 Clock Synchronization Operation

Press and hold the "Settings" button for 2 seconds to enter clock adjustment (display "CLOC"). Use "+" or "-" to adjust time (00:00-23:59). Use "Settings" to switch digits. Press "OK" to confirm time and set day of the week. Press "Settings" to set day. Exit after 10 seconds of no activity. When connected to the Bluetooth app, the phone time will automatically synchronize.

4.14 Wireless Remote Control Matching

In the off state, press and hold "Settings" and "+" for 2 seconds (display "HFA1"). Use "+" or "-" to adjust the 4th digit (remote control number 1-3). Select a number and press any button on the remote to pair. Exit pairing state after successful pairing. Press "Settings" to exit without pairing. The remote is wireless, bidirectional, and supports one-to-one operation. Multiple remotes can cause data confusion.

4.15 Screen Brightness Adjustment

In the power-on state, press and hold "+" and "-" for 2 seconds. The "AIRHEATER" icon will flash. Use "+" or "-" to adjust brightness. Press and hold "+" and "-" again to confirm. Brightness is confirmed automatically after 10 seconds of inactivity.

4.16 Check Bluetooth Password

Press "OK" and "+" simultaneously. The screen will display a 4-digit Bluetooth connection password (initial password: "0000").

4.17 Bluetooth Password Initialization

When powered off, press and hold "OK" and "+" for 2 seconds to enter password input (password: "3333"). Use "+" or "-" to adjust numbers. Use "Settings" to switch digits. Press "OK" to confirm. Press "Power" to cancel.

4.18 Oil Pump Frequency Adjustment (Non-professionals prohibited)

In the off state, press and hold "OK" and "+" for 2 seconds to enter password input (password: "3638"). After entering, "1-2.0" is displayed (1st gear frequency 2.0, 10th gear is 'A'). Use "+" or "-" to adjust frequency. Use "Settings" to switch gears. Press "OK" to confirm. Press "Power" to cancel.

4.19 Oil Pump Frequency Initialization

When powered off, press and hold "OK" and "+" for 2 seconds to enter password input (password: "6666"). Use "+" or "-" to adjust numbers. Use "Settings" to switch digits. Press "OK" to confirm. Press "Power" to cancel.

4.20 Carbon Monoxide Action Value Setting

In the shutdown state, press and hold "OK" and "+" for 2 seconds to enter password input (password: "5555"). Click "OK" to modify. Display "set L500" (500ppm shutdown value, alarm at 0.7x set value). Use "+" or "-" to adjust numbers. Use "Settings" to switch digits. Press "OK" to confirm. Press "Power" to cancel.

4.21 Fault Alarm

Digital display "E-21" indicates a fault. The fault symbol and corresponding device icon will flash. Refer to the troubleshooting section for meaning.

5. Safety Warnings and Usage Guidelines

WARNING: Read all safety warnings, instructions, illustrations, and instruction manuals provided with this diesel heater. Failure to follow all instructions may result in electric shock, fire, or serious injury.

5.1 General Safety

  • Do not replace important parts of the diesel heater without authorization. For repairs or part replacements, contact customer service for correct product specifications and models. Incorrect specifications can damage the combustion system.
  • Do not use the heater in areas where flammable vapors or dust may form, such as fuel depots, carbon depots, timber depots, granaries, or similar locations.
  • Keep away from fuel tanks, compression tanks, fire extinguishers, clothing, and other flammable items.
  • Use the machine safely. Children are not allowed to play with this machine. Cleaning and maintenance must not be carried out unsupervised by children.
  • Do not go near flammable materials when the exhaust pipe is working, as its temperature is very high.
  • Ensure no flammable or explosive materials are around the exhaust pipe during installation, use, maintenance, and scrapping to prevent fire.
  • Keep the area well-ventilated and ensure pipes are open. Place the metal exhaust pipe outdoors to prevent exhaust gases from entering the room, avoiding carbon monoxide poisoning.
  • Do not use the heater in an enclosed or unventilated place.
  • Turn off the heater when adding diesel.

5.2 Electrical and Operation Safety

  • Do not cut off the power supply directly after turning off the heating program. The equipment needs 3-5 minutes for extinguishing and cooling. Cutting off power directly can cause abnormal shutdown and negatively impact the next start.
  • If the fuel system is leaking, contact after-sales personnel for parts and guidance.
  • During operation, it is strictly forbidden to directly cut off the power supply to stop the heater.
  • When installing pipelines, ensure they are unblocked and not squeezed.
  • After overheating protection, the machine stops heating. Do not turn off the power immediately. Allow it to cool naturally before restarting.
  • The preheating and ignition stage (3-5 minutes after turning on) involves the ignition plug, oil pump, and fan working according to the preset program. Hot air will blow out after a few minutes.
  • The ignition plug requires a large current (12A or greater) to heat when starting. After successful ignition, the equipment needs 1-4A to work continuously.

5.3 Usage Environment

  • It is forbidden to use the product in high humidity, conductive dust, flammable and explosive gas, dust, materials, corrosive media, strong light, strong magnetic field, high voltage, and high current environments.
  • Power supply voltage range: DC 24V controller is applicable to 18-32V; DC 12V controller is applicable to 9-16V. Controllers with different voltages are not universal.
  • The 5kW controller can only be used on a 5kW machine; the 2kW controller can only be used on a 2kW machine.
  • If the controller or external device is damaged, use the same model and parameter device, and have it replaced by a professional.
  • It is forbidden to open the controller case without permission.
  • The equipment must be installed strictly in accordance with requirements and used under safe conditions.
  • The company is not responsible for any loss or liability caused by wrong connection, short circuit, or damage of external devices or lines.
  • When the machine body is at high temperature and the fan cannot operate normally, the machine body must be cooled down quickly. Blow cold air from the combustion-supporting air inlet to cool the machine body down to below 80°C. Prevent high temperature from scalding parts or causing fire.
  • Ensure all air ducts are unobstructed and free from folding, compression, or blockage to maintain heating efficiency and normal operation. Blockages can cause overheating, reduce efficiency, shorten service life, or damage the equipment.
  • Only use fuel that meets standards to ensure normal use and service life.
  • Adjusting oil pump frequency requires professionals.

Fire Hazard Warning: The ignition point of cotton and sponge is 150°C, paper is 130°C, cloth is 270°C, and diesel is 220°C. The hot air outlet can exceed 150°C, and the exhaust pipe outlet can exceed 270°C. Maintain adequate clearance from all flammable materials.

6. Troubleshooting and Error Codes

If you encounter any issues with your Hcalory diesel heater, refer to the table below for common error codes and their solutions.

Fault CodeCauseSolution
E022Power supply voltage is too highCheck the battery output voltage range.
E023Abnormal power supply voltageCheck the battery output voltage range.
E031Ignition plug open circuit1) Check if connecting wires/connectors are loose/broken. 2) Check if ignition plug connection plug is loose. 3) Connect ignition plug to check for damage.
E032Glow plug short circuit1) Check if connecting wire of ignition plug is short-circuited. 2) Ignition plug is damaged or main board reads incorrectly.
E041Oil pump open circuit1) Check if connecting wires/connectors of oil pump are damaged, loose or broken. 2) Check if oil pump is damaged.
E042Oil pump short circuit1) Check if connecting wire of oil pump is short-circuited. 2) Check if oil pump is blocked or damaged.
E05High temperature alarm (housing > 230°C)1) Check if cold air inlet is blocked. 2) Check if hot air outlet pipe is bent or blocked. 3) Check if fan is running normally. 4) Check if sensor is damaged.
E061Motor open circuit1) Check if connecting wires of motor are broken or motor connecting wire connector is loose. 2) Connect motor to power supply and check if it rotates.
E062Motor short circuit1) Check if connecting wires of motor are short-circuited. 2) Motor is damaged or main board is misread.
E063Abnormal fan speed1) Check if impeller is stuck. 2) Check gap between magnet on wind wheel and Hall sensor.
E07Communication between main board and remote control switch board is abnormal1) Check if connection port of remote control switch is loose. 2) Check if connection line (blue) of remote control switch is broken.
E08Turn off the flame1) Check for oil shortage, freezing, circuit blockage, pipe folding, steam drums, or oil pump stuck. 2) Check if oxygen inlet and exhaust air ducts are unobstructed. 3) Check if housing temperature sensor is in full contact and compression spring is strong. 4) Check if sensor is damaged.
E091Temperature sensor open circuit1) Check if temperature sensor connection wire and connector are damaged or loose. 2) Check if sensor is damaged.
E092Temperature sensor short circuit1) Is the temperature sensor connection line short-circuited? 2) Check if the sensor is damaged.
E10Startup failed1) Casing temperature too high, not cooled after 3 mins. 2) White smoke at exhaust port: check/clean filter, oil pump spray, ignition plug age. 3) Little/no white smoke: check oil shortage/blockage, oil pump stuck/damaged, combustion air intake/exhaust passages, ignition plug, inner wind wheels gap. 4) Ignition normal but failure reported: check housing temperature sensor contact/compression spring.
E11Carbon monoxide concentration exceeds limitIncrease air exchange in the environment; evacuate personnel to a safe environment.

7. Specifications

AttributeValue
Brand NameHcalory
Model NameTC2-SE
Power8KW
Voltage12V / 24V DC / 100~240V AC
MaterialMetal and plastic
Fuel Tank Capacity (Built-in)5L
Fuel TypeDiesel
Item Length54cm
Item Width53cm
Item Height27cm
Item Diameter7.5cm
Item Weight11.6kg
External Testing CertificationCE
CertificationCE, RoHS, FCC
Operating Temperature-40℃~40℃ (-40℉~104℉)
Bluetooth APP ControlSupport
Remote ControlSupport
Switch TypeLCD Switch
AC AdapterIncluded (100~240V)
Altitude ModeAutomatically Adjust
Diesel Consumption0.12 L/h - 0.36 L/h
Special FeaturesAutomatic Start and Stop
1.5M switch extension cableInclude

8. Bluetooth App Operating Instructions

If your heater version includes Bluetooth, you can control it via the dedicated Hcalory app. If unsure, contact customer service.

8.1 How to Download the App

Android users can download the installation package from the Google Play Store. Apple users can download from the App Store. Alternatively, scan the QR codes below to install the "Hcalory" APP.

QR code for Android app download

For Android

QR code for iOS app download

For iOS

8.2 Instructions for App Operation

  1. Adding a Device: When you first open the app, click the "+" sign to add a device.
  2. Bluetooth and Location Permissions: When searching for devices, ensure Bluetooth is enabled and precise positioning information is authorized. Refusing authorization may prevent the app from finding nearby devices.
  3. Allow Discovery: Before connecting, allow the Hcalory app to discover and connect to nearby devices.
  4. Manual Bluetooth Search: If the Bluetooth interface doesn't pop up, click the Bluetooth icon within the app to search for devices. Select the device with "hcalory" in its name. Note: If a phone is already connected, other phones cannot connect until the first phone disconnects.
  5. Operations: After successful connection, the device can perform various operations:

8.2.1 Start Heating

Click the [heating button] to start regular heating. You can choose [temperature mode] or [gear mode].

  • Temperature Mode: The device intelligently controls gears based on the set target temperature. Suitable for indoors.
  • Gear Mode: The device runs at a fixed gear. Suitable for open areas or tents with poor insulation.
Screenshot of Hcalory app showing heating mode controls.

App interface for heating mode.

8.2.2 Fan Mode

In fan mode, the fan starts independently without combustion. Can be used as a fan or exhaust fan.

Screenshot of Hcalory app showing fan mode controls.

App interface for fan mode.

8.2.3 Plateau Button

Activates plateau mode for high altitude use, adjusting oil pump frequency. Recommended for 2000-5000 meters above sea level.

Screenshot of Hcalory app showing plateau mode settings.

App interface for plateau mode settings.

8.2.4 Scheduled Timing

Set multiple timers for on/off functions. The heater must remain powered on for timed functions to work.

Screenshot of Hcalory app showing scheduled timing settings.

App interface for scheduled timing settings.

8.2.5 Other Settings

Access other settings like language and temperature unit. Provide feedback via the app.

Screenshot of Hcalory app showing general settings.

App interface for general settings.

9. User Tips

  • Pre-use Inspection: Before first use, carefully inspect the heater for any detached components, such as thermal pads, which could block the fan. Ensure all mounting screws are secure and threads are not damaged. Verify the exhaust pipe elbow has a clamp.
  • Indoor Use: While the heater can be used indoors (e.g., in tents or RVs), always ensure adequate ventilation to prevent carbon monoxide buildup. The exhaust pipe must be routed outdoors.
  • Fuel Efficiency: The heater is designed for low fuel consumption (0.12-0.36 L/h), making it economical for extended use.
  • Quiet Operation: The heater operates at a low noise level (around 65dB), which is beneficial for overnight use without significant disturbance.
  • App Control: Utilize the Bluetooth app for convenient control, scheduling, and monitoring of the heater's functions.

10. Warranty and Support

Thank you for your support and trust in Hcalory products. If you encounter any difficulties that you cannot resolve, or require after-sales technical support, please contact us.

  • Email Support: You can send an email to hcalory@hcalory.com for assistance.
  • Sales Platform: Contact our after-sales personnel through the sales platform where you purchased the product.
  • User Manual PDF: A detailed user manual in PDF format is available for download: Hcalory User Manual (PDF).

We are committed to providing detailed instructions and operational videos to assist you.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.