1. Introduction
The Victor 7200C Digital Circuit Analyzer is a versatile and high-precision instrument designed for comprehensive electrical circuit analysis. It is capable of measuring resistance, current, voltage, frequency, and performing specialized tests such as leakage protector tripping time, ground resistance, loop resistance, leakage current, load current, and load power. This manual provides detailed instructions for the safe and effective use of your device.

Image: Victor 7200C Digital Circuit Analyzer highlighting resistance and current ranges.
2. Package Contents
Upon opening your Victor 7200C package, please verify that all the following items are included:
- Victor 7200C Host Unit
- Portable Carrying Bag
- Testing Line (Test Leads)
- User Manual (this document)
- Certificate of Conformity

Image: The Victor 7200C device, portable bag, test leads, manual, and certificate.
3. Setup
3.1 Battery Installation
The Victor 7200C requires 6 x 1.5V AAA batteries (not included) for operation. To install the batteries:
- Locate the battery compartment on the back of the device.
- Use a screwdriver to open the battery compartment cover.
- Insert 6 AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover and secure it with the screw.

Image: Rear view of the Victor 7200C, showing the battery compartment cover.
3.2 Powering On/Off
Press the green power button (marked with a circle and vertical line) to turn the device on or off. The device features an automatic shut-down function to conserve battery life.
4. Operating Instructions
The Victor 7200C offers multiple testing functions. Always ensure proper connection of test leads and selection of the correct mode before performing any test.

Image: Front view of the Victor 7200C showing the display and control buttons.
4.1 Function Panel Explanation
Familiarize yourself with the device's buttons and display icons:
- FUNC Button: Cycles through different measurement modes (e.g., RCD, RE, RL, IL, IA, VA).
- HOLD Button: Freezes the current reading on the display. Press again to release.
- TEST Button: Initiates a test in the selected mode.
- Up/Down Arrow Buttons: Used to adjust parameters, such as RCD tripping current.
- Power Button: Turns the device on/off.
Display Icons: AC, DC, RCD, RE (Ground Resistance), RL (Loop Resistance), IL (Leakage Current), IA (Load Current), VA (Load Power), Ω (Ohms), A (Amperes), V (Volts), Hz (Hertz), ms (milliseconds), % (Percentage), OL (Overload), HOT (Overheat), Low pressure tips (Low Battery), Backlight, Data hold, Auto shut-down.
4.2 Socket Wiring Detection
This function checks the wiring status of a socket and displays voltage, frequency, and phase information.
- Plug the device directly into the socket to be tested.
- The display will automatically show L-N (Live-Neutral) voltage, L-PE (Live-Earth) voltage, N-PE (Neutral-Earth) voltage, frequency, and phase status.
- Observe the display for any error indicators or incorrect wiring patterns.

Image: Victor 7200C connected to a socket for wiring detection.
4.3 Leakage Protection Switch Tripping Test (RCD Test)
This test measures the tripping time of a Residual Current Device (RCD).
- Plug the device into the socket protected by the RCD.
- Press the FUNC button until the RCD mode is selected.
- Use the Up/Down arrow buttons to select the desired RCD tripping current (e.g., 10mA, 30mA, 100mA, 300mA, 500mA).
- Press the TEST button. The RCD should trip, and the device will display the tripping time.
- Reset the RCD after the test.
4.4 Ground Resistance Measurement (RE)
Measures the resistance of the grounding electrode.
- Connect the test leads: Green to Earth (PE), Red to Phase (L), Black to Neutral (N).
- Press the FUNC button until RE mode is selected.
- Press the TEST button to initiate the measurement. The ground resistance will be displayed.
4.5 Loop Resistance Measurement (RL)
Measures the resistance of the fault loop impedance.
- Connect the test leads: Green to Earth (PE), Red to Phase (L), Black to Neutral (N).
- Press the FUNC button until RL mode is selected.
- Press the TEST button to initiate the measurement. The loop resistance will be displayed.
4.6 Leakage Current Measurement (IL)
Measures the leakage current in a circuit.
- Connect the test leads according to the specific circuit configuration for leakage current measurement.
- Press the FUNC button until IL mode is selected.
- Press the TEST button to initiate the measurement. The leakage current will be displayed.
4.7 Load Current Measurement (IA)
Measures the current drawn by a connected load.
- Connect the test leads in series with the load to measure its current.
- Press the FUNC button until IA mode is selected.
- Press the TEST button to initiate the measurement. The load current will be displayed.
4.8 Load Power Measurement (VA)
Measures the apparent power of a connected load.
- Connect the test leads to measure voltage and current for power calculation.
- Press the FUNC button until VA mode is selected.
- Press the TEST button to initiate the measurement. The load power will be displayed.
For detailed wiring diagrams for each test, please refer to the comprehensive image below:

Image: Comprehensive diagram showing wiring for various tests and detailed function panel explanation.
5. Specifications
Technical specifications for the Victor 7200C Digital Circuit Analyzer:
| Parameter | Value |
|---|---|
| Resistance Range | 0.01~1300Ω |
| Current Range | 0.00~30A |
| Working Voltage | 195~250V |
| Frequency | 45~65Hz |
| Measurement Accuracy | ±(2%+2) |
| Working Temperature | 0~40℃ |
| Working Humidity | 20%~75%RH |
| Storage Temperature | -20~60℃ |
| Storage Humidity | 20%~80%RH |
| Power Supply | 6 x 1.5V AAA batteries (not included) |
| Size | 195mm x 72mm x 35mm |
| Weight | 200g (without battery) |
6. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its portable bag in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period to prevent leakage.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears to ensure accurate readings.
- Calibration: For professional use, periodic calibration by a qualified technician is recommended to maintain measurement accuracy.
7. Troubleshooting
- Device does not power on: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- "OL" (Overload) displayed: The measured value exceeds the device's range. Disconnect immediately and ensure the measurement is within the specified limits.
- "HOT" (Overheat) displayed: The device is overheating. Disconnect from the circuit and allow it to cool down before further use.
- Inaccurate readings: Ensure test leads are properly connected and not damaged. Check battery level.
- No display or flickering display: Check battery connections and power level.
8. User Tips
- Always ensure correct battery installation for proper operation and to avoid damage to the device.
- Familiarize yourself with all display icons and their meanings for accurate interpretation of test results.
- Refer to the provided wiring diagrams for safe and correct test lead connections for each specific measurement. Incorrect connections can lead to inaccurate readings or damage to the device/circuit.
- When performing RCD tests, be prepared for the circuit to trip and ensure any critical equipment is safely shut down beforehand.
9. Support
For any questions, technical assistance, or support regarding your Victor 7200C Digital Circuit Analyzer, please contact RuoShui Official Store customer service. You can find more information and contact details on the official store page:
If you wish to learn more about the product or have specific inquiries, customer service will be able to assist you promptly.
10. Product Overview Video
Watch this video for an overview of the manufacturing process and quality control at Victor/RuoShui:
Video: A brief look into the manufacturing and testing facilities of Victor/RuoShui products.