1. Product Overview
The JIKONG Smart Active Balance Battery Management System (BMS) is designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, along with a coulomb meter and Bluetooth communication capabilities.
This BMS is compatible with various battery types, including Lithium Iron Phosphate (LiFePO4), Ternary Lithium (Li-Ion), Lithium Titanate (LTO), and Sodium batteries. It is suitable for a wide range of applications, from small sightseeing vehicles and mobility scooters to high-power energy storage systems, base station backup power supplies, and solar power stations.
The system supports mobile applications (APP) for both Android and iOS operating systems, allowing users to monitor battery status, modify parameters, and control charge/discharge switches remotely.
2. Package Contents
The product package typically includes the following items:
- 1 x BMS unit
- 1 x Sampling line (70cm long)
- 1 x NTC temperature sensor (40cm long)
- 1 x Switch key (50cm long)
Optional Accessories
Various accessories are available separately to enhance the functionality and display of your JIKONG BMS:
- 2.5 Inch Display
- 4.3 Inch Touch Display
- 3.2 Inch Display
- Switch Key
- RS485 Communication Module
- Interface Board
3. Specifications
The JIKONG BMS offers robust performance and protection features. Below are the general specifications for the 40A and 60A protection board models, followed by detailed product specifications.
General Parameters (40A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 24 | Strings |
| Max. Balancing Current | 0.6 | A |
| Max. Charging Current | 40 | A |
| Max. Discharge Current | 40 | A |
| Max. Instantaneous Current | 80 | A |
| Max. Internal Loop Resistance | 1.6 | mΩ |
| Protective Plate Size | 116.8*94.8*14.6 | mm |
| Finished Weight | 325 | g |
General Parameters (60A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 24 | Strings |
| Max. Balancing Current | 0.6 | A |
| Max. Charging Current | 60 | A |
| Max. Discharge Current | 60 | A |
| Max. Instantaneous Current | 120 | A |
| Max. Internal Loop Resistance | 1.1 | mΩ |
| Protective Plate Size | 116.8*94.8*14.6 | mm |
| Finished Weight | 327 | g |
Detailed Product Specifications
Product Dimensions
The physical dimensions of the BMS vary by model. For the JK-BD6A24S-4PD series, the size is 116.8mm * 94.8mm * 14.6mm.
4. Installation and Wiring
The JK-BD6A24S-4PD series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure all connections are secure and correct before powering on the BMS.
General Wiring Steps:
- Connect all balance cables to the BMS.
- Insert the main power cables (B- and P-) into the BMS.
- Connect the B- line to the battery's total negative terminal.
- Connect the P- line to the load/charger negative terminal.
Wiring Diagrams:
Internal Structure and Interfaces:
5. Operation
5.1. Device Activation
Before powering on the protection board, ensure all balance cables are properly connected and that the P- and B- terminals are correctly wired. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The BMS does not have a physical power-on switch. It is designed for charging activation: connect a charger with a voltage 2V higher than the battery voltage to activate the board. Alternatively, if an optional light panel is installed, you can activate the BMS by inserting the cable into the light panel interface and pressing its button.
5.2. Active Equalization
The BMS utilizes active equalization technology to transfer energy from higher-voltage cells to lower-voltage cells, ensuring voltage balance with minimal energy loss. This process operates continuously, whether the battery is charging, discharging, or idle, until the voltage difference is within a set range.
To use the balancing function, set the battery type and other basic parameters (number of cells, battery capacity, trigger equalization differential pressure, voltage calibration, current calibration) via the JIKONG BMS APP. The default balancing current is 0.6A, which can be adjusted based on battery capacity. If balancing is not required, it can be disabled in the APP's BMS control page.
5.3. Communication Function
The protection board comes standard with UART serial communication. An optional one-wire communication feature is also available. Users can configure the device address and communication protocol via the APP according to their specific needs. Refer to the JIKONG Protection Board Communication Protocol Documentation for detailed protocols.
5.4. LED Battery Level Display
The BMS supports an optional LED power level display. The LED indicators show the battery's State of Charge (SOC) as follows:
| SOC Range | LED1 | LED2 | LED3 | LED4 | LED5 |
|---|---|---|---|---|---|
| 0% ~ 9% | ○ | ○ | ○ | ○ | ○ |
| 10% ~ 19% | ● | ○ | ○ | ○ | ○ |
| 20% ~ 39% | ● | ● | ○ | ○ | ○ |
| 40% ~ 59% | ● | ● | ● | ○ | ○ |
| 60% ~ 79% | ● | ● | ● | ● | ○ |
| 80% ~ 100% | ● | ● | ● | ● | ● |
Note: ● indicates LED is always on (green), ○ indicates LED is off (red).
5.5. Protection Functions
The BMS includes comprehensive protection features to safeguard your battery pack:
- Overcharge Protection & Recovery: Prevents cells from being overcharged. Charging is cut off if any cell voltage exceeds the set limit and resumes when all cells are below the recovery voltage.
- Discharge Undervoltage Protection & Recovery: Prevents cells from being over-discharged. Discharge is cut off if any cell voltage drops below the set limit and resumes when all cells are above the recovery voltage.
- Charge Overcurrent Protection & Recovery: Protects against excessive charging current. Charging is cut off if current exceeds the set limit for a specified delay and resumes after a recovery time.
- Discharge Overcurrent Protection & Recovery: Protects against excessive discharge current. Discharge is cut off if current exceeds the set limit for a specified delay and resumes after a recovery time. (Note: Max continuous discharge current cannot exceed 40A/60A depending on model).
- Over Temperature Protection & Recovery: Protects against high temperatures during charge and discharge. Operation is halted if temperature exceeds the set limit and resumes when it falls below the recovery temperature.
- Low Temperature Protection & Recovery: Protects against low temperatures during charging. Charging is halted if temperature falls below the set limit and resumes when it rises above the recovery temperature.
- Short Circuit Protection & Recovery: Automatically protects against short circuits. Users can set delay and recovery times via the APP.
5.6. Emergency Switch
In case of over-temperature, over-discharge, over-charge, or cell string issues during normal operation, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes. This provides an emergency operational window, even if a single cell reaches its automatic shutdown voltage, to prevent critical failures like being stranded.
5.7. Intelligent Sleep
The intelligent sleep function allows the BMS to enter a low-power standby mode (if charging/discharging current is less than 1A for 26 consecutive hours) to reduce its self-consumption. The BMS can be reactivated by pressing a button on an optional light panel or by connecting a charger.
5.8. APP Operation and Parameter Setting
The JIKONG BMS APP provides a user-friendly interface for monitoring and configuring your BMS. It supports both Android (minimum version 7) and iOS operating systems.
APP Installation:
Scan the QR code below to download the official JIKONG BMS APP:
Parameter Setting:
Detailed instructions for setting various parameters (e.g., voltage thresholds, current limits, temperature limits, balancing settings) are available within the APP's interface. Refer to the 'Instructions for Setting Protection Board Parameters' section within the APP for comprehensive guidance.
6. Maintenance
To ensure the longevity and optimal performance of your JIKONG BMS, consider the following maintenance guidelines:
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C) to prevent damage. Avoid exposure to excessive moisture or extreme temperatures.
- Software Updates: Keep the JIKONG BMS APP updated to the latest version to benefit from new features, bug fixes, and improved performance.
- Cleanliness: Keep the BMS unit clean and free from dust and debris, especially around cooling surfaces, to maintain effective heat dissipation.
- Parameter Review: Occasionally review the parameter settings in the APP to ensure they are still appropriate for your battery pack's condition and usage patterns.
7. Troubleshooting
If you encounter issues with your JIKONG BMS, follow these general troubleshooting steps:
- Check Connections: Verify that all balance cables, main power cables (B- and P-), and accessory connections are correctly and securely installed. Loose connections are a common cause of problems.
- Review APP Status: Use the JIKONG BMS APP to check the real-time status of your battery cells, voltage, current, and protection alarms. The APP provides detailed diagnostic information.
- Verify Parameters: Ensure that all parameters in the APP, such as battery type, cell count, voltage thresholds, and current limits, are correctly configured for your specific battery pack.
- BMS Activation: If the BMS is not responding, ensure it has been properly activated (either by charging or via an optional light panel button).
- Short Circuit Protection: If a short circuit protection is triggered, ensure there are no external wiring shorts. If the issue persists, you may need to adjust the short circuit protection delay in the APP.
- Temperature Issues: If over-temperature or low-temperature protection is active, allow the battery to return to the normal operating temperature range. Check for proper ventilation.
8. User Tips
- Confirm Compatibility: Always double-check that the BMS model (e.g., 72V 24S) matches your battery pack's voltage and series configuration to ensure proper functionality.
- Initial Setup Verification: Before the first power-on, meticulously inspect all balance cable connections and ensure the P- and B- terminals are correctly wired. Confirm the BMS is securely mounted to the battery pack to prevent potential damage or abnormal operation.
- APP for Diagnostics: Utilize the mobile APP extensively for real-time monitoring and diagnostics. It provides valuable insights into battery health and protection status.
- Adjust Parameters Carefully: When adjusting parameters in the APP, understand the implications of each setting. Incorrect settings can affect battery performance and safety.
9. Further Documentation and Support
For more detailed information, including comprehensive technical specifications, wiring diagrams for various configurations, and advanced parameter settings, please refer to the complete PDF user manual:
Download Full User Manual (PDF)
If you require further assistance or have specific technical questions, please contact the JIKONG Official Store customer support.