1. Introduction
This manual provides essential information for the installation, operation, and maintenance of your SUMRY MPPT Hybrid Solar Inverter (SP Series). This pure sine wave inverter is designed for off-grid solar power systems, integrating a solar charge controller and battery charger to provide reliable power. Please read this manual thoroughly before installation and use to ensure safe and optimal performance.
Video: SUMRY MPPT Hybrid Solar Inverter Product Overview and Demonstration.
2. Key Features
- Pure sine wave output (on/off Grid).
- Output power factor 1.0.
- WIFI & GPRS connectivity for iOS and Android monitoring (optional module required).
- Ability to operate without a battery.
- One-key restoration to factory settings.
- Built-in automatic activation for Lithium batteries.
- Dual communication ports for battery and WiFi communication.
- Built-in 120A MPPT solar charge controller.
- High PV input voltage range (60~500VDC).
- Built-in anti-dust kit for harsh environments.
- Smart battery charge design to optimize battery life.
- Dual output.
3. Safety Information
Always observe the following safety precautions to reduce the risk of injury or damage:
- Ensure all wiring is performed by qualified personnel.
- Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
- Keep the inverter away from flammable materials and moisture.
- Ensure proper grounding of the unit.
- Verify correct voltage and polarity before connecting any components.
- Install appropriate circuit breakers as specified in the installation section.
4. Installation and Wiring
4.1 Product Overview

Image: Rear panel connections of the inverter.
- AC Input
- AC Output
- PV Input
- Battery Terminals
- Communication Ports (RS232, RS485)
- Grounding Terminal
4.2 Installation Steps
Before installing and using the inverter, it is recommended to install 4 circuit breakers in the following 4 positions:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between inverter output and load.
The circuit breaker is to effectively prevent the misconnection or reverse connection of the mains input and the inverter output; when there is a short circuit, load short circuit, or overload in the output, the circuit breaker can directly cut off the circuit to protect the inverter.

Image: Recommended circuit breaker installation points.
Detailed Installation Procedure:
- Battery Connection:
Install a circuit breaker between the battery and the inverter. After successful installation, open the breaker. Connect the battery to the inverter's battery terminals. Ensure correct voltage: 24V battery for 3.6kW/4.2kW models, and 48V battery for 6.2kW models. Close the circuit breaker and measure the voltage on the battery side of the inverter to confirm it's normal.
- PV Input Connection:
Install a circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar panels to the PV input terminals. Close the circuit breaker between the PV input and the inverter. The inverter display should automatically light up and begin charging. Press the button on the bottom right corner of the inverter to start the machine. Verify 220V/230V/240V AC voltage output from the inverter.

Image: Solar panel series connection diagram. PV cable dimensions: 6-8/mm².
Note: When connecting solar panels in series, the total voltage must be within the PV voltage range (50-450VDC). Ensure the total power of solar panels does not exceed the maximum power of the inverter.
- AC Input and Output Connection:
Install a circuit breaker between the AC input and the inverter. Install another circuit breaker between the output of the inverter and the loads. After successful installation, turn on the circuit breakers for both AC input and output. Connect the machine to the mains. Turn off the mains input circuit breaker, then turn off the circuit breaker of the inverter's output after 2 minutes. This completes the installation procedure.
4.3 Circuit Breaker Specifications
| Inverter Power | Battery to Inverter Breaker | PV Input to Inverter Breaker | Utility Input to Inverter Breaker | Inverter Output to Load Breaker |
|---|---|---|---|---|
| 3.6kW | 2P80A | 2P20A | 2P63A | 2P30A |
| 4.2kW | 2P200A | 2P20A | 2P40A | 2P20A |
| 6.2kW | 2P150A | 2P20A | 2P63A | 2P25A |

Image: General System Architecture for On/Off Grid Solar Inverter.

Image: Wires and technical specifications diagram. Attention: Be sure to first ground the PE protective conductor.
5. Operating Instructions
5.1 LCD Display and Indicators

Image: LCD Display Indicators and their meanings.
| No. | Icon | Description |
|---|---|---|
| 1 | PV | PV input |
| 2 | AC | AC input |
| 3 | INPUTBATTEMP | Input voltage, input frequency, PV voltage, battery voltage, charger current |
| 4 | Setting programs | |
| 5 | Flashing with warning code, lighting with fault code | |
| 6 | OUTPUTBATTLOAD | Output voltage, output frequency, load percent, load in VA, load in watt and discharging current |
| 7 | Load level (25%, 100%) | |
| 8 | DC/AC inverter circuit is working | |
| 9 | Battery level | |
| 10 | Utility charger circuit is working | |
| 11 | Unit connects to the PV panel | |
| 12 | Unit connects to the mains | |
| 13 | BYPASS | Load is supplied by utility power |
| 14 | Unit alarm is disabled | |
| 15 | OVER LOAD | Overload |
5.2 Working Modes
The inverter offers versatile working modes for optimized power management:

Image: Sectional Charging/Output source priority modes.
- Charging Modes:
- Only Solar
- Mains First
- Solar First
- Mains & Solar (Hybrid Charge)
- Output Modes:
- Solar First
- Utility First (Mains First)
- SBU First (Inverter First)
- Hybrid Output
These modes allow for personalized energy consumption and efficient power management.
5.3 Communication
The SUMRY ECO series machine has two communication ports:
- RS232 Communication Port: Used for WiFi module communication. The WiFi module enables remote monitoring and basic parameter settings via a mobile phone app, provided the inverter is near a router. (WiFi module sold separately).
- RS485 Communication Port: Used for lithium battery BMS communication. If using lithium batteries with BMS communication, ensure the battery uses the PACE or PYLONTECH communication protocol.

Image: Inverter COMM port and Battery RS485 port.

Image: RS485 communication line for lithium battery BMS connection.
6. Maintenance
- Regularly inspect all wiring connections for tightness and corrosion.
- Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling. The built-in anti-dust kit helps, but periodic cleaning is recommended.
- Monitor the LCD display for any warning or fault codes and refer to the troubleshooting section if issues arise.
- Ensure batteries are maintained according to their manufacturer's guidelines to optimize battery life, especially with the smart battery charge design.
- For any complex issues or internal repairs, contact qualified service personnel.

Image: Intelligent Cooling Fan system.
7. Troubleshooting
This section provides guidance for common issues. For persistent problems, contact customer support.
- Inverter not turning on: Check battery connections, circuit breakers, and ensure sufficient battery voltage.
- No AC output: Verify AC output circuit breaker, check load connections, and ensure the inverter is in an appropriate output mode.
- Overload warning: Reduce the connected load. The inverter has overload protection.
- Fault codes on display: Refer to the LCD display section (Section 5.1) to interpret the fault code and take appropriate action.
- Battery not charging: Check PV input connections, solar panel orientation, and ensure the solar charge controller is active. Verify battery health.
Q&A Hint: Some users inquire about output voltage (110V vs 220V). Ensure you select the correct model variant for your region's voltage requirements. The product description mentions single-phase output 220-240VAC, but some models might have different outputs or be configurable.
8. Specifications
The SUMRY MPPT Hybrid Solar Inverter (SP Series) is available in various models with different power ratings. Below are the detailed specifications:

Image: Product Data Sheet for SUMRY ECO Series Inverters.
| Parameter | VICTOR NM-ECO-3.6KW PLUS | VICTOR NM-ECO-4.2KW PLUS | VICTOR NM-ECO-6.2KW |
|---|---|---|---|
| PV INPUT (DC) | |||
| Nominal DC Voltage/Max.DC Voltage | 360/500VDC | 360/500VDC | 360/500VDC |
| Start-up Voltage/Initial Feeding Voltage | 60-450VDC | 60-450VDC | 60-450VDC |
| MPPT Voltage Range | 60-450VDC | 60-450VDC | 60-450VDC |
| Max. Input Current | 18A | 18A | 22A |
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC |
| Output Voltage Range | 195-253VAC | 195-253VAC | 195-253VAC |
| Nominal Output Current | 15.7A | 18.2A | 27.0A |
| Power Factor | >0.99 | >0.99 | >0.99 |
| EFFICIENCY | |||
| Max. Solar Conversion Efficiency (DC/AC) | 98% | 98% | 98% |
| TWO LOAD OUTPUT POWER | |||
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Maximum Second Load (battery mode) | 1200W | 1400W | 2067W |
| Maximum Load Cut Off Voltage | 26VDC | 52VDC | 28VDC |
| Maximum Load Return Voltage | 27VDC | 54VDC | 29VDC |
| OFF-GRID OPERATION | |||
| AC Input | AC Start-up Voltage/Auto Restart Voltage: 120-140VAC/180VAC, Acceptable Input Voltage Range: 90-280VAC or 170-280VAC | ||
| Frequency Range | 59.5-60.5Hz | ||
| Maximum Input Current | 21.1A | 24.7A | 36.4A |
| PV INPUT (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| MPPT Voltage Range | 60-450VDC | ||
| Maximum Input Current | 18A | 18A | 22A |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Wave Form | Pure sine wave | ||
| Efficiency (DC/AC) | 94% | ||
| BATTERY & CHARGER | |||
| Nominal DC Voltage | 24VDC | 48VDC | 48VDC |
| Maximum AC Charging Current | 100A | 60A | 120A |
| Maximum Solar+AC Charging Current | 120A | 80A | 120A |
| HYBRID OPERATION | |||
| PV INPUT (DC) | Same as above | ||
| GRID OUTPUT (AC) | Same as above | ||
| AC Input | Same as above | ||
| GENERAL | |||
| Physical (D*W*H) (mm) | 420*360*110 | 500*415*180 | 500*415*180 |
| Net Weight (kg) | 8.0 | 8.9 | 10.3 |
| Gross Weight (kg) | 9.0 | 10.0 | 11.3 |
| INTERFACE | |||
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | ||
| ENVIRONMENT | |||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Operating Temperature | -10°C ~ 50°C | ||
| STANDARD | |||
| Compliance Safety | CE | ||
9. User Tips
- Voltage Compatibility: Always double-check the output voltage of the inverter (e.g., 110V or 220V) to ensure it matches your regional requirements and the appliances you intend to power. If you need a specific voltage, confirm the model supports it before purchase.
- Battery Selection: Pay close attention to the required battery voltage (24V or 48V) based on your inverter's power rating (3.6kW/4.2kW for 24V, 6.2kW for 48V).
- Professional Installation: While the manual provides detailed steps, consider professional installation for complex setups to ensure safety and optimal performance.
- Monitoring: Utilize the optional WiFi module for remote monitoring of your system's performance and battery status, which can help in proactive maintenance.
10. Warranty and Support
All SUMRY products come with a 1-year warranty from the date of purchase. For technical support, warranty claims, or any inquiries, please contact SUMRY customer service. Ensure you have your product model and purchase details ready when contacting support.