EVCO EV3B23N7 Digital Controller Instruction Manual

Model: EV3B23N7 | Brand: EVCO

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the EVCO EV3B23N7 Digital Controller. This device is a digital thermostat designed for low-temperature refrigeration units, offering precise temperature control and monitoring. It operates on a 230V AC power supply and is compatible with NTC probes.

2. Specifications

FeatureSpecification
ModelEV3B23N7
Power Supply230 VAC, 50/60Hz
Measure InputNTC (-40.0 to 105.0 °C / -40 to 220 °F)
Fan Relay Rating5A 250V~
Compressor Relay Rating16A 250V~
Defrost Relay Rating8A 250V~
Dimensions (L x W x H)23 cm x 15 cm x 10 cm (approximate package size)
Weight0.4 kg (approximate package weight)
OriginMainland China

3. Package Contents

The standard package includes:

  • 1x EVCO EV3B23N7 Digital Controller
  • Depending on the variant purchased, NTC probes may or may not be included. Please check your order details.

4. Safety Information

  • Always disconnect power before installation or maintenance.
  • Installation should be performed by qualified personnel in accordance with local electrical codes.
  • Ensure proper grounding to prevent electrical shock.
  • Do not expose the controller to water or excessive humidity.
  • Verify that the power supply voltage matches the controller's specifications (230 VAC).
  • Do not exceed the maximum current ratings for the relay outputs.

5. Installation

5.1 Mounting

The EV3B23N7 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Secure the controller firmly in its mounting cutout.

5.2 Wiring Diagram

Refer to the wiring diagram on the back of the unit for correct connections. The image below provides a clear view of the terminal layout and corresponding functions.

Rear view of EVCO EV3B23N7 Digital Controller with wiring diagram and specifications.
Figure 1: Rear view of the EVCO EV3B23N7 Digital Controller showing the wiring diagram and technical label.

Wiring Connections:

  • Terminals 1-2: FAN (Fan output, 5A 250V~)
  • Terminals 3-4: COMP (Compressor output, 16A 250V~)
  • Terminals 5-6: DEF (Defrost output, 8A 250V~)
  • Terminal 7: Power Supply (Live, 230 VAC)
  • Terminal 8: Power Supply (Neutral, 230 VAC)
  • Terminals 9-10: DIG. INP. (Digital Input)
  • Terminals 11-12: CAB. EVAP. (Cabinet/Evaporator NTC Probe Input)

Ensure all connections are secure and correctly matched to their respective loads and power sources. Incorrect wiring can damage the unit or connected equipment.

Bottom view of EVCO EV3B23N7 Digital Controller showing terminal blocks.
Figure 2: Bottom view of the controller, illustrating the terminal blocks for wiring.

6. Operation

The EVCO EV3B23N7 features a clear digital display and intuitive touch buttons for control. The front panel includes the following controls:

Front view of EVCO EV3B23N7 Digital Controller showing display and buttons.
Figure 3: Front view of the EVCO EV3B23N7 Digital Controller, highlighting the display and control buttons.
  • SET Button: Used to access and modify parameters.
  • Power Button: Turns the unit ON/OFF or enters/exits standby mode.
  • Down Arrow Button: Decreases values or navigates menu options.
  • Up Arrow Button: Increases values or navigates menu options.
  • Defrost/Fan Button: Initiates manual defrost cycle or controls fan operation (functionality may vary based on configuration).

Detailed programming instructions for setting temperature setpoints, differentials, and other operational parameters are typically found in the full product manual or specific programming guides provided by EVCO. Consult these resources for advanced configuration.

7. Maintenance

7.1 Cleaning

  • Wipe the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Ensure no liquid enters the unit.

7.2 Inspection

  • Periodically check wiring connections for tightness and signs of corrosion.
  • Inspect the probes for damage or wear.

8. Troubleshooting

  • No Display/No Power: Check power supply connections (Terminals 7 & 8) and ensure the unit is receiving 230 VAC. Verify the power button is pressed.
  • Incorrect Temperature Reading: Check the NTC probe connections (Terminals 11 & 12). Ensure the probe is correctly installed in the cabinet/evaporator and is not damaged.
  • Relay Not Activating: Verify the setpoint and differential settings. Check the wiring to the respective load (Fan, Compressor, Defrost) and ensure the load itself is functional.
  • Unit Not Responding to Buttons: Try cycling the power to reset the unit. If the issue persists, contact technical support.

9. User Tips

  • For optimal performance, ensure the NTC probes are correctly positioned to accurately measure the desired temperature.
  • Familiarize yourself with the programming menu to customize settings for your specific refrigeration application.
  • Keep the display clean for easy readability of temperature and status indicators.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt and product model number (EV3B23N7) handy when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.