1. Introduction

This infrared thermometer is used for measuring the temperature of the object's surface, which is applicable for various hot, hazardous or hard-to-reach objects without contact safely and quickly.

2. Safety Warnings & Cautions

2.1. Warning:

To avoid potential harm or damage to people, please pay attention to the following:

  • Before use, check the plastic housing carefully. If damaged, do not use.
  • Do not point laser directly at eyes or indirectly off reflective surfaces.
  • Do not use in environments with explosive gas, steam, or dust.

2.2. Caution:

To avoid damage to the unit or target, protect from the following situations:

  • EMF (electro-magnetic fields) from arc welders, induction heaters.
  • Thermal shock (caused by large or abrupt ambient temperature changes) - allow 30 minutes for unit to stabilize before use.
  • Do not leave the unit on or near objects of high temperature.

3. Setup

3.1. Battery Installation

  1. Locate the battery compartment at the bottom of the handle.
  2. Use a screwdriver to rotate the switch knob of the battery compartment to the 'OPEN' position.
  3. Open the battery compartment cover.
  4. Insert 2 x 1.5V AAA batteries, ensuring correct polarity.
  5. Close the battery compartment cover and rotate the switch knob to the 'LOCK' position.

Video: Demonstrates opening the battery compartment, inserting AAA batteries, and closing it securely.

4. Operating Instructions

4.1. Distance to Spot Size Ratio (D:S)

When taking measurements, pay attention to the Distance to Spot (D:S) ratio. As the distance (D) from the thermometer to the target surface increases, the spot diameter (S) on the target surface becomes larger. The D:S ratio for this device is approximately 12:1.

Diagram showing Distance to Spot Ratio (D:S=12:1). A thermometer points at a surface, illustrating how the measured spot size (S) increases with distance (D). At 12 inches, spot is 1 inch; at 36 inches, spot is 3 inches; at 60 inches, spot is 5 inches.

Image: Diagram illustrating the relationship between measurement distance and the size of the area being measured.

4.2. Scope of Observation

Ensure that the measured target is larger than the measuring area. For smaller targets, bring the infrared thermometer closer. To ensure accuracy, the target should be at least twice as large as the measuring area.

4.3. Emissivity

Different materials have different emissivity. The emissivity for most materials is listed below. For more accurate values, consider using a thermometer with adjustable emissivity and adjust it accordingly.

Emissivity Parallel Table
MaterialEmissivityMaterialEmissivityMaterialEmissivityMaterialEmissivity
Aluminum0.30Iron0.70Asbestos0.95Brick0.50
Bituminous0.95Limestone0.98Basalt0.70Oil0.94
Brass0.50Paint0.93Brick0.90Paper0.95
Carbon0.85Plastic0.95Ceramics0.95Rubber0.95
Concrete0.95Sand0.90Copper0.95Skin0.98
Oil Sludge0.94Snow0.90Frozen Items0.90Steel0.80
Hot Food0.93Textile0.94Glass0.85Water0.93
Ice0.98Wood0.94

4.4. Measurement Modes

The device features a backlit LCD display with various indicators:

Diagram of the thermometer's LCD display and buttons. Labels include HOLD, SCAN, Laser indicator, Backlight indicator, Battery indicator, °F/°C, Temperature value, Emissivity symbol, Max symbol, and buttons for Laser, °C/°F conversion, and Backlight.

Image: Overview of the thermometer's display and controls.

4.4.1. Single Measurement

  1. Pull and release the trigger.
  2. The laser point will activate to help aim at the target (laser is for aiming only).
  3. The temperature of the target will be displayed on the LCD. The "HOLD" symbol will be shown, indicating the current temperature value is captured.

4.4.2. Continuous Measurement

  1. Pull and hold the trigger.
  2. Slowly move the thermometer across the surface.
  3. The thermometer will continuously scan and display the temperature on the LCD. The "SCAN" symbol will be shown.
  4. The maximum temperature value during continuous measurement will also be displayed.

4.5. Function Buttons

  • Laser Switch: Press to turn the laser pointer on or off. The laser is for aiming only.
  • °C/°F Conversion: Press to switch between Celsius (°C) and Fahrenheit (°F) temperature units.
  • Backlight Switch: Press to turn the LCD backlight on or off.
  • Emissivity Adjustment (for models with this feature): Long press the °C/°F button. The preset emissivity (e.g., 0.95) will be displayed. Use the Laser or Backlight buttons to increase or decrease the emissivity. Press the °C/°F button again to save the setting.

5. Maintenance

5.1. Lens Cleaning

  1. Use compressed air to blow away debris.
  2. Gently wipe away residual small debris with a camel hair brush.
  3. Carefully wipe the surface with a wet cotton cloth.

5.2. Shell Cleaning

Use a sponge or soft cloth with soap and water to clean the device's shell.

6. Troubleshooting

  • No display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate readings: Ensure the D:S ratio is appropriate for the measurement distance. Verify the target size is sufficient. If measuring reflective surfaces, consider adjusting emissivity (if available) or applying a non-reflective coating.
  • Laser not working: Check if the laser switch is activated.
  • Device not turning on: Ensure batteries are correctly inserted and have sufficient charge.

7. Specifications

FeatureSpecification
Measuring Temperature Range-50°C to 600°C (-58°F to 1112°F)
Measurement Accuracy≥0°C (32°F): ±1.5°C (±2.7°F) or ±1.5% of max value; <0°C (32°F): ±3°C (±5.4°F) or ±3% of max value
Emissivity0.1-1.0 adjustable
Maximum Value DisplayYES
Repeatability1% of reading or 1°C (33.8°F)
Response Time500mSec, 95% Response
Response Wavelength8-14um
Ambient Operating Temperature0°C to 50°C (32°F to 122°F)
Relative Humidity10-90%RH non-condensing
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Power Supply2 x 1.5V AAA Battery
Battery Life (laser off)12 hours
Distance to Object Ratio (D:S)12:1

8. User Tips

  • For best accuracy, allow the thermometer to acclimate to the ambient temperature of the measurement environment for at least 30 minutes before use.
  • Always ensure the target object fills the measurement spot for reliable readings.
  • Avoid measuring through glass or other transparent surfaces, as this can lead to inaccurate results.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's contact information or the official NJTY website.

A PDF version of this manual may be available for download from the product page or manufacturer's website: View User Manual (PDF)


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.