1. Introduction
The JIKONG FACTORY BMS JK-B2A8S30PHC is an intelligent Battery Management System designed for large-capacity series lithium battery packs. It supports 4S to 8S configurations for Li-ion, LiFePO4, and LTO battery types. This BMS features a 300A continuous charge/discharge current and a 2A active balancing current, ensuring optimal battery performance and longevity.
Key functionalities include voltage acquisition, high-current active balancing, overcharge and over-discharge protection, overcurrent and over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS remote capabilities. The system is managed via a mobile APP (Android and iOS) or PC software, allowing users to monitor battery status and adjust parameters.

2. Setup and Installation
2.1. Packing List
The standard package for the JK-B2A8S30PHC includes the following components:
- BMS x 1
- Sampling line x 1 (70cm long)
- NTC (Temperature Sensor) x 1 (40cm long)
- Switch key x 1 (50cm long)

2.2. Product Dimensions
The JK-B2A8S-30P series protection board has dimensions of 174.77mm × 127.26mm × 17.6mm. Please ensure adequate space for installation and heat dissipation.

2.3. Wiring and Connections
Before installation, gently handle the packaging and the protection board. Inspect for any impact marks or damage. The JK-B2A8S-30P series is suitable for 3-8 series lithium battery packs. The wiring method varies depending on the number of cells in your battery pack. Ensure all balance cables are properly connected and the P- and B- lines are correctly wired before powering on.
General Wiring Steps:
- Connect all balance cables to the BMS.
- Insert the main power cables (B- and P-) into the BMS.
- Connect the B-line to the battery negative terminal and the P-line to the battery positive terminal.


2.4. Interface Definitions
The BMS features various interfaces for communication and control:

P1 (XH-10AW-2.54) - Balance and Acquisition Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | B- | Total negative battery |
| 2-9 | B1-B8 | Positive terminals for battery strings 1-8 |
| 10 | B+ | Protection board power supply, connected to the battery positive |
P2 (A1254WF-7A) - Heating Interface:
| Pin | Name | Description |
|---|---|---|
| 1-5 | HT- | Heater element negative electrode |
| 6 | CD+ | Charge indication input positive terminal |
| 7 | CD- | Charge indication input negative terminal |
P3 (A1254WF-6A) - Display Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | VCC | Display power output |
| 2 | A | Display RS485 signal positive |
| 3 | B | Display RS485 signal negative |
| 4 | GND | Power negative |
| 5 | K+ | Activate signal positive |
| 6 | K- | Activate signal negative electrode |
P4 (A1254WF-4A) - Communication Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | 485 B | RS485 signal negative terminal |
| 2 | 485 A | RS485 signal positive terminal |
| 3 | CAN H | CAN signal positive terminal |
| 4 | CAN L | CAN signal negative terminal |
P5 (1.25T-4PWT) - GPS Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | VGPS | Power output, voltage close to B+ |
| 2 | TX | UART TX, 3.3V |
| 3 | RX | UART RX, 3.3V |
| 4 | GND | Power/signal ground |
P6 (HY2.0-4P) - Temperature Interface 1:
| Pin | Name | Description |
|---|---|---|
| 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B |
| 3 | T2A | Second temperature sensor pin A |
| 4 | T2B | Second temperature sensor pin B |
P7 (HY2.0-4P) - Temperature Interface 2 (Optional 4 external):
| Pin | Name | Description |
|---|---|---|
| 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B |
| 3 | T4A | Fourth temperature sensor pin A |
| 4 | T4B | Fourth temperature sensor pin B |
P8 (A1254WF-3A) - Parallel Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | GND | Signal ground |
| 2 | P-EN | Parallel module enable signal (low level to enable) |
| 3 | P-status | Parallel module status signal |
P9 (A1254WF-2A) - Buzzer Interface:
| Pin | Name | Description |
|---|---|---|
| 1 | VCC | Buzzer power supply positive |
| 2 | GND | Buzzer power negative |
D1 - Bluetooth Connection Indicator: When Bluetooth is connected, the indicator is steady on. When disconnected, it blinks.
P- (Main Discharge/Charge Negative): Connects to external load or negative terminal of charger.
B- (Main Battery Negative): Connects to the negative battery terminal.
2.5. Device Activation
Before powering on the protection board, double-check all balance cable connections and ensure the P- and B- lines are correctly connected. Verify that the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a power-on control switch. It is designed for charging activation: the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the BMS supports key activation and display activation. If you have an optional display screen and button, simply connect the cable to the display interface and press the button to activate the device.
3. Operating Instructions
3.1. APP Installation and Parameter Setting
The JIKONG BMS can be managed via a mobile APP (Android and iOS) or PC software. To install the mobile APP, scan the QR code provided in the manual. Android devices require version 7 or higher.


Before using the balancing function, set the basic battery parameters in the APP, including battery type, number of cells, battery capacity, balance trigger voltage difference, and voltage/current calibration. Default parameters are detailed in Section 5.2.
The APP allows you to view battery status, modify working parameters, and control charge/discharge switches. For specific parameter settings, refer to the 'Instructions for Setting Protection Board Parameters' document.
3.2. Active Equalization
The BMS uses energy transfer active balancing technology. Energy is transferred from higher-voltage cells to lower-voltage cells to achieve voltage balance with minimal energy loss. The default balance current is 2A. You can adjust the balance current based on your battery capacity, but it is recommended not to exceed 0.2C of the battery capacity.
Active balancing automatically activates when the voltage difference between any two battery strings exceeds the set value and turns off when the difference falls within the set range. If balancing is not required, you can disable it in the BMS control page of the APP.

3.3. Protection Functions
The BMS provides comprehensive protection features:
- Overcharge Protection and Recovery: Standard feature. Users can set single overcharge protection voltage and recovery voltage via the APP. The BMS will stop charging if any cell exceeds the set voltage and resume when all cells are below the recovery voltage.
- Discharge Undervoltage Protection and Recovery: Standard feature. Users can set undervoltage protection voltage, recovery voltage, and automatic shutdown voltage. The BMS will stop discharging if any cell falls below the set voltage and resume when all cells are above the recovery voltage.
- Charge Overcurrent Protection and Recovery: Standard feature. Users can set continuous charging current, overcurrent delay, and release time. The BMS will stop charging if the current exceeds the set value for the specified delay and resume after the release time.
- Discharge Overcurrent Protection and Recovery: Standard feature. Users can set continuous discharge current, overcurrent delay, and release time. The BMS will stop discharging if the current exceeds the set value for the specified delay and resume after the release time. (Note: Maximum continuous discharge current should not exceed 300A).
- Over-temperature Protection and Recovery: Standard feature for both charging and discharging. Users can set protection and recovery temperatures via the APP. The BMS will stop operation if temperatures exceed limits and resume when they fall within safe ranges.
- Low-temperature Protection and Recovery: Standard feature for charging. Users can set protection and recovery temperatures via the APP. The BMS will stop charging if temperatures fall below limits and resume when they rise above recovery temperatures. Heating function is recommended for extremely cold areas.
- Short-circuit Protection and Recovery: Standard feature. The trigger current is not user-settable, but delay (µs) and recovery time (S) can be adjusted via the APP. If a short circuit occurs, the BMS will stop operation and resume after the recovery time. If charging triggers a short circuit due to high peak current, increase the short circuit protection delay.
3.4. Heating Function (Optional)
The BMS supports an optional heating function to warm the battery in low-temperature conditions, preventing reduced battery activity. The designed heating current is 4A. Users can select this function and match appropriate heating equipment based on their needs. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary protection.
3.5. Battery Parallel Function (Optional)
The BMS supports an optional battery parallel function for energy storage applications. This requires a parallel module and enabling the charging current limiting function in the APP.3.6. Discharge Precharge Function (Optional)
The BMS offers an optional discharge precharge function with a default time of 5 seconds. Users can enable or disable this function as needed. Setting the precharge time to 0 disables the function.
3.7. Emergency Switch
The BMS includes a standard emergency switch function. If issues like over-temperature, over-discharge, overcharge, or cell drop occur during normal use, activating the emergency switch in the APP will enable charge and discharge for 30 minutes. This provides an emergency use period. Even if a single cell reaches automatic shutdown voltage during this time, the protection board will continue to operate until the 30-minute cycle ends, preventing critical failures.
3.8. Intelligent Sleep
The BMS features an intelligent sleep function to reduce its own energy consumption when in standby (charging/discharging current less than 1A for 26 consecutive hours). Users can enable or disable this function via the APP. To reactivate the BMS from sleep, press the switch button or connect a charger.
3.9. Communication Function (Optional)
The BMS supports optional CAN/RS485 communication. Users can select CAN or RS485 for multiplexed ports in the APP. When using communication, set the address and protocol according to your requirements. Refer to the Jikong Protection Board communication protocol document for details.

4. Maintenance
To ensure the longevity and optimal performance of your JIKONG BMS, consider the following maintenance guidelines:
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Cleanliness: Keep the BMS unit clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Temperature Management: Ensure the BMS operates within its specified temperature range (-30°C to 70°C). Adequate ventilation is crucial, especially for high-current applications.
- Firmware Updates: Check the official JIKONG website or APP for any available firmware updates to ensure your BMS has the latest features and bug fixes.
- Avoid Physical Damage: Protect the BMS from physical shocks, vibrations, and moisture. The aluminum alloy shell provides good protection, but extreme conditions should be avoided.
5. Troubleshooting
If you encounter issues with your JIKONG BMS, consider the following general troubleshooting steps:
- No Power/Activation Issues: Ensure all wiring is correct and secure. If using charging activation, verify the charger voltage is at least 2V higher than the battery voltage. If using a button, ensure it's properly connected and pressed.
- Balancing Problems: Check the balance trigger voltage difference setting in the APP. Ensure the balance current is appropriate for your battery capacity.
- Protection Triggered: If a protection (overcharge, over-discharge, overcurrent, over-temperature, low-temperature, short-circuit) is triggered, check the corresponding parameters in the APP. Review the battery status and environmental conditions that might have caused the trigger.
- Communication Issues: Verify Bluetooth connection. For RS485/CAN, ensure correct wiring and protocol settings in the APP.
- Abnormal Readings: If voltage or current readings appear incorrect, check the calibration settings in the APP.
For detailed troubleshooting and parameter adjustments, refer to the 'Instructions for Setting Protection Board Parameters' within the JIKONG APP or the comprehensive PDF manual.
6. Specifications
6.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 10-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max Number of Collection Strings | 8 | Strings |
| Max Balancing Current | 2 | A |
| Max Charging Current | 300 | A |
| Max Discharge Current | 300 | A |
| Max Instantaneous Current | 600 | A |
| Max Internal Loop Resistance | 0.3 | mΩ |
| Protective Plate Size | 174.77*127.26*17.6 | mm |
| Finished Weight | 421 | g |
6.2. Default Parameters (for JK-B2A8S30PHC)
| Parameter | Li-Ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | µS |
| Short-circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
| Discharge Precharge Time | 0 | 0 | 0 | S |
Note: The data tolerance range is ±2mm for dimensions.

7. User Tips
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters and balancing settings for your specific battery chemistry and usage patterns.
- Cold Weather Operation: If operating in extremely cold environments, consider utilizing the optional heating function to maintain battery performance and prevent low-temperature charging issues.
- Wiring Verification: Always double-check all wiring connections, especially balance leads and main power lines, before initial power-up to prevent damage to the BMS or battery pack.
8. Further Information and Support
For more detailed technical information, wiring diagrams, and advanced parameter settings, please refer to the official JIKONG Lithium Battery Active Balance Protection Board Maintenance Manual (PDF).
A PDF version of the user manual is available for download: JIKONG BMS User Manual (PDF).
For any further assistance or technical support, please contact JIKONG customer service.