1. Introduction
The SUMRY HGX 4.5KW is a high-performance off-grid solar inverter designed to provide reliable power for your home or business. This pure sine wave inverter features a built-in 5600W MPPT solar charger, ensuring efficient conversion of solar energy. It is capable of running without a battery and supports various battery types for optimized performance. This manual provides essential information for the safe installation, operation, and maintenance of your inverter.

Key Features:
- Pure sine wave output for sensitive electronics.
- Capable of operating without a battery.
- Integrated 5600W MPPT solar charger with 150A maximum charging current.
- Wide PV input voltage range: 55Vdc-450Vdc.
- SBU Mode for flexible power source prioritization (Utility, Battery, PV).
- Smart battery charger design for enhanced battery life.
- Cold restart function.
- Optional WiFi & GPRS module for iOS and Android app monitoring.
- 6.25-inch LCD display with touch buttons.
2. Safety Information
Please read and understand all safety instructions before installing, operating, or servicing this inverter. Failure to follow these instructions may result in electric shock, fire, severe injury, or death.
- All wiring must be performed by qualified personnel.
- Install a DC circuit breaker between the inverter and PV modules.
- Use proper recommended cable sizes for all connections.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep children away from the inverter and its connections.
Intelligent Protection Systems:
The inverter is equipped with comprehensive protection features:

- Overload Protection
- Overheating Protection
- High/Low Voltage Protection
- Battery Protection
- Short Circuit Protection
- Overcurrent Protection
- Anti-Reverse Protection
- Power Failure Protection
3. Product Overview
Familiarize yourself with the components and interface of your SUMRY HGX 4.5KW inverter.

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function touch buttons (ESC, UP, DOWN, ENTER)
- Power on/off switch
- AC input terminals
- AC output terminals
- PV input terminals
- Battery input terminals
- Circuit breaker
- RS485/RS232 communication port
4. Specifications
Detailed technical specifications for the SUMRY HGX 4.5KW inverter.

| Feature | Specification |
|---|---|
| Model Number | HGX 4.5KW |
| Power Rating | 4500W |
| Output Voltage | 230VAC |
| Nominal DC Voltage (Battery) | 24VDC |
| Output Current (AC) | 10A |
| Max. AC Charging Current | 150A |
| MPPT Voltage Range | 55Vdc-450Vdc |
| MPPT Charger Capacity | 5600W |
| Max. PV Array Power | 7200W |
| MPPT Efficiency | 100% |
| Solar Charge Max. Efficiency | 99% |
| Output Frequency | 50Hz/60Hz |
| Waveform | Pure Sine Wave |
| Output Type | SINGLE |
| Net Weight | 10KG |
| Dimensions (D*W*H) | 400*250*89mm |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | -15°C to 60°C |
| Certification | CE |
| Origin | Mainland China |
5. Installation and Setup
Proper installation is crucial for the safe and efficient operation of your solar inverter. Ensure all wiring is carried out by qualified personnel.
System Connection Diagram:
The inverter can be integrated into a hybrid power system, drawing from solar modules, a generator, or the utility grid, and supplying power to battery packs and home appliances.

PV Connection (Solar Panel Wiring):
CAUTION: Before connecting to PV modules, install a DC circuit breaker separately between the inverter and PV modules. All wiring must be performed by a qualified personnel. It's very important for system safety and efficient operation to use appropriate cable size for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

Series Connection:
Connecting panels in series increases the total voltage of the PV system. The total voltage must be less than the inverter's maximum input voltage (Voc).
Parallel Connection:
Connecting panels in parallel increases the total current of the PV system. The total current should not exceed the maximum PV input current of the hybrid inverter.
Recommended PV Cable Dimensions: 6-8A/mm²
PV Module Selection Guidelines:
When selecting PV modules, consider the following:
- Open circuit voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit voltage (Voc) of PV modules should be higher than the min. PV Array MPPT Voltage range.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.5KW/6.5KW | 1 x 12AWG | 4 | 1.2 Nm |
Example for 250Wp PV module (reference):
| SOLAR INPUT | Q'ty of panels | Total input power |
|---|---|---|
| 6 pcs in serial | 6 pcs | 1500W |
| 8 pcs in serial | 8 pcs | 2000W |
| 12 pcs in serial | 12 pcs | 3000W |
| 13 pcs in serial | 13 pcs | 3250W |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W |
6. Battery Compatibility
The SUMRY HGX 4.5KW inverter is compatible with a variety of 24V battery types, including lead-acid and lithium batteries.

Compatible battery types include:
- Flooded (FLD)
- Gel (GEL)
- Lithium-iron phosphate (LI)
- Lithium-ion (LI)
- AGM/Sealed (SLD)
- User custom Battery
7. Operating Modes
The inverter offers flexible charging and output source priority modes to suit different energy management needs.
Charging Modes:

SUB Mode:
- Solar charging as first priority.
- Utility will supply power to the loads when solar energy is not sufficient.
- Battery provides power only when solar energy and utility are not available.
SBU Mode:
- Solar charging as first priority.
- Battery will supply power to the loads when solar energy is not sufficient.
- Utility provides power only when battery voltage drops to a warning voltage.
In SBU mode, the machine prioritizes the use of solar energy, while solar energy charges the battery. If there is no solar energy at night, the battery is used first. The battery then converts to mains power, while mains power charges the battery.
Output Source Priority:

- Solar Priority: Utilizes solar power as the primary energy source.
- Utility Priority: Utilizes utility grid power as the primary energy source, with solar as a secondary source.
- SBU (Solar & Utility): A hybrid approach where solar is prioritized, followed by battery, and then utility.
8. Monitoring and Control
The inverter can be monitored and controlled remotely via the 'smartess App' on your smartphone or tablet. An optional WiFi/GPRS module is required for this functionality.

Download the 'smartess App' from the App Store (iOS) or Google Play Store (Android).
9. Troubleshooting
This section provides guidance for common issues you might encounter. For complex problems, please contact technical support.
- No Power Output: Check all connections (PV, battery, AC input/output). Ensure the circuit breaker is not tripped. Verify battery voltage is within operating range.
- Charging Issues: Confirm PV panels are receiving sufficient sunlight. Check PV input voltage and current. Ensure MPPT settings are correct for your battery type.
- Error Codes on LCD: Refer to the inverter's LCD display for specific error codes. Consult the full product manual (if available) or contact support with the error code for detailed solutions.
- Overload Warning: Reduce the connected load. The inverter's protection system will shut down if the load exceeds its capacity.
- Overheating: Ensure the inverter has adequate ventilation. Clear any obstructions from cooling vents. Check ambient temperature.
10. User Tips
- Optimal Sizing: Ensure your solar panel array and battery bank are appropriately sized for your energy consumption to maximize efficiency and system longevity.
- Regular Monitoring: Utilize the LCD display or the 'smartess App' to regularly monitor system performance, battery status, and energy production.
- Ventilation: Always ensure the inverter is installed in a well-ventilated area to prevent overheating, which can reduce efficiency and lifespan.
- Cable Management: Use appropriate cable gauges and ensure all connections are tight and secure to minimize power loss and prevent safety hazards.
11. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Cleanliness: Keep the inverter's exterior clean and free from dust and debris. Ensure cooling vents are unobstructed.
- Connection Checks: Periodically inspect all electrical connections (PV, battery, AC) for tightness and signs of corrosion.
- Battery Health: If using lead-acid batteries, check electrolyte levels and terminal cleanliness as per battery manufacturer guidelines. Monitor battery voltage and health via the inverter's display or app.
- Environmental Conditions: Ensure the inverter is operating within its specified temperature and humidity ranges.
12. Warranty and Support
The SUMRY HGX 4.5KW inverter comes with a 1-year warranty. It is certified with CE, RoHS, and FC standards, ensuring compliance with relevant safety and environmental regulations.
For technical support, warranty claims, or further assistance, please contact your authorized SUMRY dealer or the manufacturer's customer service.