1. Safety Information
To prevent electric shock, fire, or personal injury, and to ensure safe operation of this product, please read all safety instructions before use.
- Do not modify this product or use it for purposes other than its intended use, as this may reduce the protection provided by the product.
- Replace the battery when the battery level indicator shows low power to prevent inaccurate measurements.
- Do not use the product if it is working abnormally or is damaged.
- Refer to emissivity information for actual temperature. Reflective objects may cause measured temperatures to be lower than actual temperatures, posing a burn hazard.
- Do not place batteries or battery packs near heat sources or fire. Do not expose to direct sunlight.
- Do not disassemble or squeeze batteries or battery packs. Batteries contain hazardous chemicals that may cause burns or explosions. If contact with chemicals occurs, wash with water and seek medical attention.
- If the product is not used for a long time, remove the battery to prevent leakage and damage.
- Keep the battery and battery pack clean and dry. Clean the connector with a dry, clean cloth.
- If battery leakage occurs, repair the product before use.
- If the rechargeable battery becomes hot (>50°C) during charging, disconnect the charger and move the product or battery to a cool, non-flammable location.
- Do not insert metal objects into the connectors.
- Only qualified technicians should repair the product.
- To avoid electric shock, always remove the test leads before disassembling the battery, connecting USB, charging, or disassembling the casing.
Safety Symbols
| Symbol | Description | Symbol | Description |
|---|---|---|---|
| ⚠ | Warning, Danger | HOLD | Data Hold Function |
| ⚠ | Warning, Dangerous Voltage. Electric Shock Hazard | RANGE | Auto Range Setting |
| AUTO | Auto Range Measurement | NCV | Non-Contact AC Voltage Measurement |
| LIVE | Live Wire Identification | ★ | Temperature Measurement |
| AC/V | AC Voltage Measurement | AC/A | AC Current Measurement |
| DC/V | DC Voltage Measurement | DC/A | DC Current Measurement |
| Ω | Resistance Measurement | →|← | Diode, PN Junction Forward Voltage Measurement |
| ⚡ | Continuity Measurement | ′ | Capacitance Measurement |
| Hz % | Frequency and Duty Cycle Measurement |
2. Product Features
- Compact size, light weight, and portable.
- Thermal imaging can be saved and viewed on the device.
- Thermal imaging can be reproduced with PC software.
- 3.5-inch LCD screen with 320*480 resolution.
- 15 pseudocolor modes: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Dark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Dark Blue.
- Supports audible and visual alarms when temperature exceeds set limits.
- Supports up to 64GB TF memory card.
- Multimeter measurements support data waveform storage and reproduction with PC software.
- Multimeter functions: DC voltage, AC voltage, DC current, AC current, resistance, diode, continuity, capacitance, temperature, NCV (non-contact measurement), LIVE (live/neutral wire identification).
- Multimeter display maximum reading: 19999.
- Analog pointer display.
- Multimeter polarity display: Automatic.
- Multimeter range: Automatic or Manual.
- Multimeter refresh rate: Approximately 3 times per second.
- Dual display on screen: Displays frequency when measuring voltage, and ambient temperature when measuring other signals.
- Supports software upgrades via USB drive.
- 11 languages: Chinese, English, German, Russian, French, Spanish, Portuguese, Korean, Japanese, Italian, Polish.
- Powered by 18650 lithium battery, 8-hour endurance, removable, supports USB charging.
- Automatic screen off and automatic shutdown functions.


3. Product Overview
3.1. Front Panel
The front panel features the LCD display, function buttons, input terminals, and communication ports.

Controls and Ports (Thermal Imaging Mode)
- Long press 3s: Power On/Off
- Short press: Switch Multimeter Range / Long press: Switch Pseudocolor
- Short press: Manual Range / Long press: Switch Multimeter Function
- Short press: Multi-function Range Switch / Long press: Flashlight On/Off
- Short press: Multimeter Function Switch / Long press: Settings Menu
- AC or DC Current Measurement Port
- COM Common Measurement Input Port
- USB TYPE-C Interface
- Voltage, Resistance, Diode, Temperature, Capacitance, Frequency Measurement Port
- 1/4-20 inch Threaded Bracket Interface
Controls and Ports (Multimeter Mode)
- Long press 3s: Power On/Off
- Short press: Switch Multimeter Range
- Short press: Manual Range / Relative Value / Long press: Switch Key Function
- Short press: Multi-function Range Switch / Long press: Flashlight On/Off
- Short press: Thermal Imaging Function Switch / Long press: Settings Menu
- AC or DC Current Measurement Port
- COM Common Measurement Input Port
- USB TYPE-C Interface
- Short press: Multimeter Data Hold / Long press: Save Screenshot
- Voltage, Resistance, Diode, Temperature, Capacitance, Frequency Measurement Port
- 1/4-20 inch Threaded Bracket Interface
3.2. Rear Panel
The rear panel includes the battery compartment, stand, and cooling fan.

- Thermal Imaging Lens
- Thermal Imaging Macro Lens (optional, non-standard configuration)
- Stand (closed and open states)
- Rotary Switch Lock
- Removable 18650 Lithium Battery
4. Thermal Imaging Operation
The thermal imaging interface displays center temperature, maximum temperature, minimum temperature, and the difference between maximum and minimum temperatures. It also shows multimeter measurement data.






4.1. Screenshot Saving
In thermal imaging mode, long press the SAVE button. A dialog box will appear on the screen indicating that the screenshot has been saved successfully.
To view saved screenshots, long press the MENU button to enter the settings menu, then select the "File" menu.
4.2. Temperature Measurement
Move the device to position the crosshairs in the center of the screen over the object to be measured. The current temperature of the object will be displayed.
Long press the MENU button to enter the settings menu and configure parameters such as "Emissivity", "Distance", "Temperature Range", and "Unit".
4.3. Emissivity Adjustment
Long press the MENU button, select "Emissivity" from the settings menu to adjust the emissivity based on the material of the object being measured.
You can select "Custom" and use the up/down keys on the screen to adjust the emissivity value. Long pressing the up/down keys will accelerate the adjustment.
4.4. Temperature Range Switching
Long press the MENU button, select "Temperature Range" from the settings menu to switch the temperature range. The default is auto-range. High temperature range is suitable for measuring objects from 100°C to 550°C, and low temperature range for -20°C to 150°C.
In auto-range, the screen may freeze for 2-3 seconds when switching between low and high temperature ranges.
4.5. Pseudocolor Switching
In thermal imaging mode, long press the right button on the device to switch between 15 pseudocolor modes: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Dark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Dark Blue.
4.6. Alarm Settings
Long press the MENU button, select "Alarm Settings" from the settings menu. Once "Enable" is turned on, you can enable "Visual Alarm" and "Audible Alarm". Select "Rule" in this interface, use the up/down keys to set the alarm rule (less than or greater than), then exit. Select "Alarm Threshold" to set the alarm temperature value.
4.7. Temperature Unit
Long press the MENU button, select "Unit" from the settings menu. Continuously press the confirmation option to switch between temperature units: °C, °F, K.
4.8. Display Parameters
Long press the MENU button, select "Display Parameters" from the settings menu to enter the display settings interface. Select a parameter, press the confirmation option to "Disable", press again to "Enable". Use the up/down keys to set other parameters.
4.9. Measurement Distance
Long press the MENU button, select "Distance" from the settings menu. Press the confirmation option to set the measurement distance. Use the up/down keys to adjust the value. Measurement distance range: 0.3-10 meters.
5. Multimeter Operation
The multimeter features DC voltage, AC voltage, DC current, AC current, resistance, diode, continuity, capacitance, temperature, NCV, LIVE, frequency, and duty cycle measurement functions. It supports auto-range and manual range switching (default is auto-range) and HOLD data saving. It also has powerful data waveform recording and reproduction with PC software. The multimeter interface supports always-on screen. Voltage/current auto-switching: When measuring voltage, if the test leads are inserted into the current measurement port, the instrument will automatically switch to the current measurement interface. (Note: To avoid electric shock, remove test leads before connecting to USB. Multimeter functions are disabled during charging).
5.1. Range Switching
Short press the right button on the device to switch multimeter ranges. This is for major range switching. After selecting a range, short press the function button to switch sub-ranges. The screen will display the current range icon and measurement unit.
5.2. AC/DC Voltage Measurement
Insert the red test lead into the "VΩ" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the DC voltage measurement interface. The measurement unit will be "V". Short press the function button to switch between DC voltage and AC voltage measurement interfaces.
Read the measurement result from the display. In DC voltage mode, the secondary display shows ambient temperature. In AC voltage mode, the secondary display shows frequency.
Caution:
Do not input voltage higher than AC 600V. Higher voltages are possible to measure but may damage the instrument. Exercise extreme caution to avoid electric shock when measuring high voltages.
When the measured voltage is ≥30V (safe voltage), the LCD will display a high voltage warning symbol "⚠".
5.3. AC/DC Current Measurement
Insert the red test lead into the "A" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the current measurement interface. The measurement unit will be "A". Short press the function button to switch between DC current and AC current measurement interfaces.
Disconnect the circuit to be measured. Connect the test leads to the break point, then power on.
Read the measurement result from the display. In DC current mode, the secondary display shows ambient temperature. In AC current mode, the secondary display shows frequency.
Voltage/Current auto-switching: When measuring voltage, if the multimeter test leads are inserted into the "A" jack, the instrument can automatically switch to the current measurement interface.
Caution:
To prevent damage to the circuit and potential fuse blow, do not connect the probes across a live circuit (in parallel) when the test leads are inserted into the current terminals. This will cause a short circuit. This instrument measures a maximum current of 10A.
5.4. Resistance Measurement
Insert the red test lead into the "VΩ" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the resistance measurement interface. The measurement unit will be "Ω".
Connect the test leads across the two ends of the resistance to be measured.
Read the measurement result from the display. The secondary display shows ambient temperature.
Caution:
If the measured resistance is open circuit or exceeds the maximum range of the instrument, the display will show "OL".
When measuring in-circuit resistance, all power to the circuit must be turned off and all capacitors discharged before measurement to ensure accuracy.
Do not input voltage higher than DC or AC 30V to avoid injury or damage.
5.5. Capacitance Measurement
Insert the red test lead into the "VΩ" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the capacitance measurement interface. The measurement unit will be "nF".
Connect the test leads across the two ends of the capacitor to be measured.
Read the measurement result from the display. The secondary display shows ambient temperature.
Caution:
If the measured capacitor is short-circuited or its value exceeds the maximum range of the instrument, the display will show "OL".
For capacitance measurements greater than 400uF, a certain stabilization time is required for accurate readings.
To ensure measurement accuracy, it is recommended to fully discharge the capacitor before connecting it to the instrument. This is especially important for high-voltage capacitors to prevent damage to the instrument and personal injury.
5.6. Continuity Test
Insert the red test lead into the "VΩ" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the continuity measurement interface. The measurement unit will be "Ω". Short press the function button to switch between continuity and diode measurement interfaces. In diode measurement mode, the display shows "V".
In continuity mode, connect the test leads across the load of the circuit to be measured. If the resistance between the two ends is <30Ω, the circuit is considered continuous, and a continuous beep will sound. If the resistance is >50Ω, no sound will be emitted. The secondary display shows ambient temperature in continuity mode.
Caution:
When checking in-circuit continuity, all power to the circuit must be turned off and all capacitors discharged before measurement.
Do not input voltage higher than DC or AC 30V to avoid injury or damage.
When switching to diode mode, the display shows the approximate forward PN junction voltage of the measured diode. For silicon PN junctions, a value of 500~800mV is generally considered normal. The secondary display shows ambient temperature.
Caution:
If the measured diode is open circuit or reverse polarity, the display will show "OL".
When measuring in-circuit diodes, all power to the circuit must be turned off and all capacitors discharged before measurement.
Do not input voltage higher than DC or AC 30V to avoid injury or damage.
5.7. Frequency and Duty Cycle Measurement
Insert the red test lead into the "VΩ" jack and the black test lead into the "COM" jack.
Short press the right button to switch to the frequency measurement interface. The measurement unit will be "Hz", and "0.0%" will be displayed before the frequency unit for duty cycle.
Connect the test leads across the two ends of the object to be measured. Read the test result from the display. The main display shows frequency, and the secondary display shows duty cycle.
Caution:
Do not input voltage higher than DC 60V or AC 30V to avoid damage to the instrument and personal injury.
5.8. Temperature Measurement
5.8.1. Ambient Temperature Auto-detection
The product is set to automatically detect ambient temperature (secondary display). The accuracy is for reference only (the product will refresh the current temperature when powered on in different environments).
5.8.2. HVAC Water Temperature Detection
In open circuit, it displays "Current Ambient Temperature". Connect a K-type temperature sensor to measure in Celsius (°C) or Fahrenheit (°F) (F = °C * 1.8 + 32).
Short press the function button to switch temperature units: °F, °C.
The thermocouple should be inserted with the positive (+) end into the "VΩ" jack and the negative (-) end into the "COM" jack.
5.9. NCV/LIVE
Short press the right button to switch to "NCV" mode. No test leads are needed.
Non-Contact AC Voltage (NCV) detection: Place the top end of the instrument (NCV position) close to the conductor or socket to be detected. When current is detected, the measurement interface will display "—" "——" "———" according to the detection strength, accompanied by a beeping sound. The secondary display shows ambient temperature.
If no electric field is detected, the main display shows "EF", and the secondary display shows ambient temperature.
Caution:
The NCV sensing point should be close to the electric field to be measured, otherwise, the measurement sensitivity will be affected.
When the measured electric field voltage is >100V AC, pay attention to whether the conductor of the measured electric field is insulated to avoid injury and personal safety risks.
In this interface, short press the function button to switch between NCV and LIVE measurement interfaces.
5.9.1. LIVE Wire Identification
After switching to "LIVE" mode: Insert the red test lead into the V terminal, touch the power socket or bare wire to distinguish between live and neutral wires.
Product no detection display status: Main display shows "LIVE".
When neutral wire is detected, the main display "LIVE" remains unchanged.
When live wire is detected, the main display shows "OL" symbol, and the beeping sound changes according to the induction strength, indicating the live wire voltage strength.
The secondary display shows ambient temperature.
Caution:
When using the LIVE function, to prevent the COM input terminal from interfering with the accuracy of distinguishing live and neutral wires, please remove the black test lead from the COM terminal.
In case of dense high voltage, the product's judgment of "live wire" accuracy may be unstable. It should be judged by the LCD display and the frequency of the beeping sound.
5.10. Manual and Auto Range Switching
In voltage, current, resistance, capacitance, and frequency measurement interfaces, short press the RANGE REL button to enter the range setting interface. You can manually set the range for more precise measurements.
5.11. Data Hold Function / Waveform Data Storage
In multimeter mode, short press the HOLD SAVE button to hold the multimeter data.
Long press the HOLD SAVE button to save the current waveform data. To delete waveform data files, long press the MENU button, enter the settings menu, and select the "File" menu to delete saved content.
6. System Settings
6.1. Startup Mode
Set the default mode (thermal imaging or multimeter) when the device powers on.
6.2. Backlight & Sound Settings
Reducing backlight brightness and enabling screen off time can effectively extend battery life.
The continuity buzzer in the multimeter is not affected by sound settings.
6.3. Thermal Imaging Settings
- Pseudocolor: Modify the display relationship between thermal imaging temperature and color.
- Temperature Unit: Modify the unit for overall temperature measurement.
- Emissivity: Set emissivity based on the object being measured. Click the bottom range button for quick settings.
- Temperature Range: Recommended to set based on actual measured temperature. When auto-range is selected, the screen may freeze for about 2-3 seconds when switching between low and high temperature ranges. High temperature range is suitable for 100°C to 550°C, low temperature range for -20°C to 150°C.
6.4. Storage Settings
You can preview saved thermal imaging screenshots. Select a thumbnail to open the corresponding image. Once opened, you can delete the image. In the system menu, find "Format Storage" to format the storage.
6.5. USB Mode
In USB mode, you can connect the device to a computer via USB to view files on the device. To exit this mode, disconnect the USB. (Note: To avoid electric shock, remove test leads before connecting USB to other devices).
6.6. Multimeter Interface Always-On Setting
In the system settings interface, find "Multimeter Screen Always On" menu. Press the confirmation option to enable or disable the multimeter screen always-on function.
6.7. Voltage/Current Auto-Switching
When measuring voltage, if the multimeter test leads are inserted into the "A" jack, the instrument will automatically switch to the current measurement interface, allowing direct current measurement.
7. PC Software Usage
The PC software allows for thermal imaging temperature reproduction and multimeter data waveform reproduction.
PC software download address: Refer to the official website or included PDF manual for download link.
7.1. Thermal Imaging Temperature Reproduction
First, open the PC software. Select the thermal imaging tab. Click the open button to select a thermal imaging screenshot. In the thermal imaging area, click the left mouse button to get the temperature value of the clicked area.
7.2. Multimeter Data Waveform Reproduction
First, open the PC software. Select the multimeter tab. Click the open button to select a multimeter waveform data file. Move the mouse to the waveform area, and scroll the mouse wheel to zoom in or out of the waveform.
8. Specifications


8.1. Thermal Imaging Parameters
| Parameter | Value |
|---|---|
| Sensor | Vanadium Oxide (VOx) |
| Image Capture Frequency | 25Hz |
| Module Output Pixels | 256x192 |
| Display Image Resolution | 427 x 320 |
| Field of View (FOV) | 50.0°(H) x 37.2°(V) |
| Emissivity | 0.1 - 0.99 adjustable, default 0.95 |
| Measurement Temperature Range | -20°C ~ +550°C |
| Mode | Auto Gain |
| Color Palette | White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Dark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Dark Blue |
| Temperature Measurement Error | ±2°C or ±2% |
| Display Temperature Accuracy | 0.1°C / 0.1°F |
8.2. Multimeter Parameters
| Parameter | Value |
|---|---|
| DC Max Input Voltage | 1000V |
| AC Max Input Voltage | 750V |
| Max Current Measurement | 10A |
| Max Resistance Measurement | 99.99MΩ |
| Max Capacitance Measurement | 199.99mF |
| Duty Cycle Measurement Range | 0.1% ~ 99.9% |
| Diode Measurement Range | 0V ~ 3V |
| Continuity Detection Max Resistance | 199.99 Ω |
| Display Digits | 19999 counts, refreshes approx. 3 times/second |
Accuracy Table
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| AC Voltage | 1.9999V | 0.0001V | 1.0% + 3 |
| 19.999V | 0.001V | ||
| 199.99V | 0.01V | ||
| 999.9V | 0.1V | ||
| DC Voltage | 1.9999V | 0.0001V | 1.0% + 3 |
| 19.999V | 0.001V | ||
| 199.99V | 0.01V | ||
| 999.9V | 0.1V | ||
| AC Current | 1.9999A | 0.0001A | 1.0% + 3 |
| 9.999A | 0.001A | ||
| DC Current | 1.9999A | 0.0001A | 1.0% + 3 |
| 9.999A | 0.001A | ||
| Resistance | 199.99Ω | 0.01Ω | 0.5% + 3 |
| 1.9999KΩ | 0.1Ω | ||
| 19.999KΩ | 0.001KΩ | ||
| 199.99KΩ | 0.01KΩ | ||
| 1999.9KΩ | 0.1KΩ | ||
| 19.999MΩ | 0.001MΩ | ||
| Diode | 3.000V | 0.001V | 10% |
| Capacitance | 19.999nF | 0.001nF | 2% + 5 |
| 199.99nF | 0.01nF | ||
| 1999.9nF | 0.1nF | ||
| 19.999uF | 0.001uF | ||
| 199.99uF | 0.01uF | ||
| 1999.9uF | 0.1uF | 5% + 5 | |
| 19.999mF | 0.001mF |
8.3. Other Device Parameters
| Parameter | Value |
|---|---|
| Display Screen | 3.5-inch 320*480 resolution |
| USB Interface | Type-C USB |
| Max TF Card Capacity | 64GB |
| Image Format | BMP file |
| Battery | Removable 18650 Lithium Battery |
| Storage Temperature | -20~60°C (-4~140°F) |
| Operating Temperature | 0~50°C (32~122°F) |
| Operating Humidity | <85%RH (non-condensing) |
| Product Dimensions | 134 mm * 64mm * 28 mm |
| Product Weight | Main unit weight: 198g (including battery), Package weight: 390g |

9. Maintenance
To ensure the longevity and optimal performance of your OWON OEL15/OEL30 Series device, follow these maintenance guidelines:
- Cleaning: Keep the device, battery, and battery pack clean and dry. Use a dry, clean cloth to wipe the connectors and the device casing. Do not use abrasive cleaners or solvents.
- Storage: If the product is not used for an extended period, remove the battery to prevent leakage and damage. Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: If the rechargeable battery becomes hot (>50°C) during charging, disconnect the charger and move the product or battery to a cool, non-flammable location.
- Inspection: Regularly inspect the test leads and connectors for any signs of wear or damage. Replace them if necessary.
- Calibration: For precise measurements, periodic calibration by qualified personnel is recommended.
10. Troubleshooting
This section provides guidance for common issues. For complex problems, please contact customer support or a qualified technician.
- Device not powering on: Ensure the battery is properly installed and charged. If using USB power, ensure the connection is secure.
- Inaccurate measurements: Check test lead connections. Verify the correct measurement mode and range are selected. For thermal imaging, ensure emissivity settings are correct for the material being measured. For multimeter functions, ensure test leads are inserted into the correct ports.
- Screen freezing or abnormal display: If the product is working abnormally, do not use it. This may indicate an internal issue. In thermal imaging auto-range, a 2-3 second freeze is normal when switching temperature ranges.
- Battery leakage: If battery leakage occurs, repair the product before further use to prevent damage to the device or personal injury.
- No sound/alarm: Check sound settings in the system menu. Ensure alarm thresholds are correctly set for thermal imaging.
- USB connection issues: Ensure test leads are removed before connecting to USB. Verify the USB cable and port are functioning correctly.
11. User Tips
- Always read the safety instructions thoroughly before operating the device.
- Familiarize yourself with the front and rear panel layouts and button functions to ensure efficient operation.
- For thermal imaging, adjust emissivity based on the material being inspected for more accurate temperature readings.
- When using multimeter functions, double-check that the test leads are connected to the correct input jacks for the desired measurement (voltage, current, resistance, etc.) to prevent damage to the device or circuit.
- Utilize the data hold and waveform storage features to capture and analyze measurements effectively, especially for dynamic signals.
- Keep the device's firmware updated using the USB drive method for optimal performance and new features.
12. Warranty and Support
This product is designed for reliable performance. For any technical assistance, warranty claims, or service inquiries, please refer to the official OWON website or contact your authorized dealer. Keep your purchase receipt as proof of purchase.