1. Safety Cautions
Please read this manual carefully before installation and use. This machine contains high voltage and is potentially dangerous. Any abnormalities must be handled by qualified personnel. Do not open the outer cover by yourself.
- Store in a dry place and keep away from water.
- Keep the inverter away from high temperature, fire, or direct sunlight.
- Please replace batteries with the same brand and model; do not mix with other different types or models of batteries.
- Keep batteries or battery packs away from fire, otherwise they could explode and cause harm.
- Keep the inverter ventilated (at least keep a barrier-free distance of 15cm for the front and rear airways).
- Do not pile up sundries upon the inverter.
Warning: Batteries will deteriorate over time and need to be replaced or handled by professionals once battery failure occurs, otherwise battery flooding might cause dangers, such as burning. An annual maintenance and checking of batteries is recommended.
Do not disassemble, avoid humidity, fire, or high temperatures. Ensure proper ventilation and do not pile items on top.
2. Product Introduction
This series of off-grid inverters are controlled by a digitized CPU and produce a true sine wave DC/AC output, converting battery power to AC voltage. The output is a pure sine wave, suitable for continuous operation from 0% to 100% load conditions.
Its surge power can be more than double the rated power, making it suitable for various load types, including inductive and capacitive loads. Applications include computers, communications, yachts, recreational vehicles, family recreational devices, motors, electric tools, industrial control devices, video players, and household appliances.
2.1 Features
- Pure sine wave output (THD<3%)
- High conversion efficiency (up to 92% maximum)
- Full LED display of working state
- Low battery capacity warning
- All-digital control display
- CE/FCC/LVD/ROSE norms compliant
- Wide compatibility with most AC input products
- Intelligent temperature-controlled fan: The fan rotates automatically when the temperature reaches a certain threshold.
- Eight-digit intelligent protection: overload, high voltage, low voltage, overheating, reverse connection, short circuit, over-current protection.
High compatibility with various electrical appliances.
Ideal for outdoor and emergency power needs.
3. Specifications
| Attribute | Value |
|---|---|
| Model Number | Pure Sine Wave Inverter 1000W 1600W 2000W 3000W 4000W 5000W 6000W |
| Type | DC/AC Inverters |
| Output Type | SINGLE |
| Output Frequency | 50Hz, 60Hz |
| Output Voltage Waveform | Pure sine wave (THD<3%) |
| Output Voltage | 110V / 220V (selectable) |
| Input Voltage | 12V/24V/48V/60V/72V (depending on model) |
| Efficiency | 89%-91% |
| Protection | Short-circuit, over-power, over-charge, over-temperature, low/high battery voltage, reverse polarity (external fuse) |
| Size | 28*7*15cm (varies by model) |
| Weight | 1.9 kg (varies by model) |
| Certification | CE |
Power Ratings (Continuous / Peak):
- 1000W model: 300W continuous, 1000W peak
- 1600W model: 800W continuous, 1600W peak
- 2200W model: 1000W continuous, 2200W peak
- 3000W model: 1300W continuous, 3000W peak
- 4000W model: 1600W continuous, 4000W peak
- 5000W model: 2200W continuous, 5000W peak
- 6000W model: 2700W continuous, 6000W peak
Continuous and Peak Power Ratings by Model.
Detailed specifications for 1000W, 1600W, and 3000W models.
Detailed specifications for 4000W, 5000W, and 6000W models.
4. Panel Description
4.1 Front Panel Description
- POWER ON/OFF Switch: The inverter starts when switched to ON.
- AC output socket: Different types of sockets are provided to meet global user demands.
4.2 Front Panel Diagram
Front Panel Layout with Multi-function LCD.
4.3 Indications of LED signals on the front panel
Upgraded LCD display provides real-time battery and running status.
| LED Display | State | Description |
|---|---|---|
| Green | Normal | Inverter is operating normally. |
| Orange | Standby Saving Mode | Inverter is in power-saving mode. |
| Red | Abnormal/Protection | Indicates a fault or protection event. Refer to troubleshooting. |
Battery LED: Displays the remaining capacity of the external batteries (4 red LEDs).
Load LED: Displays the current load capacity (4 red LEDs).
4.4 Rear Panel Description
- Battery Input Terminals (+)(-)
- Air Vents Fan: For thermal dissipation.
- Earth terminal of the chassis (FG)
- Air inlets: Used for thermal dissipation of the inverter. Keep ventilation to assure maximum life.
5. Settings of Initial Output Voltage, Frequency, Standby Saving Mode
5.1 Instruction of Initial Factory Setting
- Factory Setting is 220Vac/50Hz or 110Vac/60Hz.
- The Standby Saving Mode is enabled by default (not in use).
6. Protection Functions
6.1 Input Protection
- Battery polarity reversal protection: If the input voltage of batteries is reversed, the internal or external fuse will blow. The inverter should be returned to the factory for repair. (External fuse is supplied with a backup for easy replacement).
- Low battery voltage protection: When battery voltage is lower than the specification, the inverter switches off automatically, gives 3 beeps, and the fault light turns on.
- High battery voltage protection: When battery voltage is higher than the specification, the inverter switches off automatically, gives 4 beeps, and the fault light turns on.
Warning: When using this series of inverters, the battery pack input voltage setting must be within the normal operating voltage range specified in the product specifications. Incorrect voltage (too low or too high) can prevent startup or damage the inverter.
6.2 Output Protection
- Over temperature protection (OTP): If the internal temperature is too high, the OTP will activate, alert with 5 continuous beeps, and the fault light will be on. It will return to normal automatically when the temperature falls to 50°C.
- AC output anomaly protection: The inverter will restart if the AC output voltage is too high or too low.
- AC output short circuit protection: If the output is short-circuited or the load increases sharply, it will recover automatically or manually.
- Output overload protection (OLP): If the load reaches 120%, the buzzer will sound continuously for 10 seconds, then the inverter will power off automatically and restart in 10 seconds (continuous recycling).
- Output superload protection: The inverter will power off if the load reaches 150% and lasts for 1 second, and the FAULT light on the panel will flash.
6.3 Instruction of Fault Signal
| Buzzer | Fault Information | LED Indication |
|---|---|---|
| 1 beep | Normal Startup | Green LED on |
| 2 beeps | Undervoltage Warning | Battery voltage running out. |
| 3 beeps | Undervoltage Protection | Red LED on, battery voltage too low or depleted. |
| 4 beeps | Overvoltage Protection | Red LED on, battery voltage too high. |
| 5 beeps | Overheat Protection | Red LED on, inverter interior is overheated. |
| Continuous beep | Overload Protection | Inverter powers off in 10 seconds, restarts in 10 seconds. |
7. Installation and Wiring
7.1 Battery Wire
The battery wire should not be longer than 1.5 meters, and its diameter should accord with safety regulations to handle the magnitude of current. An undersized wire can overheat or even burn. Refer to the table below for wire recommendations.
| Rated Current | Wire CSA (mm²) | AWG |
|---|---|---|
| 16A-25A | 2.5 | 12 |
| 25A-32A | 4 | 10 |
| 32A-40A | 6 | 8 |
| 40A-60A | 10 | 6 |
| 63A-80A | 16 | 4 |
| 80A-100A | 25 | 2 |
| 100A-125A | 35 | 1 |
| ≥125A | 50 | 0 |
7.2 Battery Pack Recommendation
- The battery pack should meet requirements for minimum safe startup, full load discharge time, and minimum setting capacity. Users can choose larger capacity to meet discharge time needs.
- The inverter working time is calculated by: Battery Capacity (AH) × Battery Voltage (V) × 0.8 (battery discharge coefficient) × 0.9 (inverter conversion efficiency) ÷ Load (W) = Working Time (Hours).
- For example, a 12V/60Ah battery with a 220V/100W filament lamp: Working Time = (12V × 60AH × 0.8 × 0.9) ÷ 100W = 5.18 Hours.
7.3 Installation Requirements
Consider the machine's weight when fixing it. Avoid high temperature and high-pressure environments to ensure a long service life. The machine has a built-in fan for forced-air cooling; ensure air vents are unobstructed. Avoid operating in high temperatures or under overload conditions to prevent breakdown.
Please spare a distance of 15cm for the air vents without obstacles.
7.4 Fixing Recommendation
Four fixing orifices are reserved on the outer case. Horizontal fixing is recommended, ensuring air vents remain unobstructed.
7.5 Reference Diagram of Setup
Basic connection diagram for the inverter and a 12V battery.
Battery series connection diagrams for 24V, 48V, 60V, and 72V systems.
Detailed 24VDC to 120VAC System Connection Diagram. Note: Connect in strict accordance with the sequence (Install: 1, 2, 3, 4), otherwise disassembly sequence is opposite to wiring sequence. Always connect the DC Battery FIRST and disconnect LAST.
8. Operating Instructions
To operate the inverter, ensure it is properly connected to a compatible DC battery bank as per the installation instructions. Once connected, switch the POWER ON/OFF button to 'ON'. The LCD display will show real-time information such as battery level, input/output voltage, frequency, temperature, and power consumption.
Plug your AC appliances into the output sockets. The inverter is designed to power a wide range of devices, from small electronics to larger appliances, within its continuous and peak power limits.
Demonstration of the inverter powering a kettle, electric drill, and hairdryer.
Important: This inverter is a power converter and does NOT charge batteries. Ensure your batteries are charged separately.
8.1 Cautions for the Electrical Load
- Motor-load devices generate huge starting current (about 6-10 times higher than rated current). Pay attention to the instantaneous starting power to ensure it does not exceed the inverter's maximum output power.
- For capacitive or rectifying load devices (e.g., switching power supplies), it is recommended to start them under no-load or light-load conditions, then slowly increase the load after the inverter has started successfully.
9. Maintenance
- Regularly check battery connections for tightness and corrosion.
- Ensure the inverter's air vents are clean and unobstructed to prevent overheating.
- An annual maintenance and checking of batteries by professionals is recommended to prevent battery failure and potential hazards.
- Keep the inverter in a dry, cool, and well-ventilated area.
10. Troubleshooting
This series of inverters are professional products. Any improper use or alteration might cause damage or electric shock. Users should perform basic troubleshooting according to the table below. If the machine still cannot resume normal work, consult your dealer or return it to the factory for repair.
| Fault State | Possible Causes | Recommended Solutions |
|---|---|---|
| Input voltage abnormal | Battery voltage too low or too high. | Check DC voltage, ensure battery voltage is within specified range. |
| Overheat | Air vents blocked, excessive load, high ambient temperature. | Reduce loads, lower ambient temperature, check if air vents are unblocked. |
| Overload protection | Load exceeds rating or requires large starting current. | Check if the load exceeds the rating or is an inductive/capacitive device. Reduce load. |
| Short circuit protection | Output is short-circuited. | Check for short circuits in the load. |
| Working time too short | Battery capacity too small. | Confirm specifications, consider increasing battery capacity. |
11. User Tips
- The inverter's LCD display is highly informative, showing battery charge, input/output voltage, frequency, and wattage.
- For sudden high loads, the inverter may go into protection mode. Applying loads smoothly is recommended.
- The 4000W model has been reported to handle multiple office appliances (computer, printer, lights, coffee machine) simultaneously.
- The 1000W model (approx. 500W continuous) can easily power a fan.
- The inverter is suitable for powering refrigerators, TVs, kettles, boilers, and microwaves.
- When connecting to a solar system with an MPPT controller, ensure the DC battery bank is connected FIRST and disconnected LAST. Use the MPPT controller's LOAD output to control a Normally Open (NO) relay for the inverter's DC input.
- The inverter does not have a battery charging function. It is a power converter only.
12. Warranty and Support
This product provides a one-year free warranty under normal use. Please do not replace components yourself or conduct any unauthorized maintenance or modification, as this will affect your warranty.
For any issues not covered in the troubleshooting section, please contact your dealer or the manufacturer for support.