1. Introduction
The LCTC KWS-303 series is an advanced 8-in-1 multi-function AC energy meter designed for precise monitoring of electrical parameters. Available in KWS-303WF (WiFi), KWS-303L (RS485), and KWS-303 (Standard) variants, these meters provide real-time data on voltage, current, power, frequency, power factor, active energy, timing, and temperature. Featuring a high-definition TFT color screen and DIN rail mounting, the KWS-303 series offers convenient installation and comprehensive electrical monitoring for various applications.

2. Features
- 8-in-1 Digital Display: Simultaneously displays voltage, current, power, frequency, power factor, active energy, timing, and temperature on a single screen for easy real-time viewing.
- High-Definition TFT Color Screen: A 0.96-inch screen with wide viewing angles and high contrast ensures readability even in low-light conditions.
- Mobile Remote Control (KWS-303WF only): WiFi networking and cloud remote capabilities allow control and monitoring via a mobile phone anytime, anywhere. Supports multiple timed data settings and power-on configurations.
- Standard DIN Rail Mounting: Easy installation without screws or fasteners, utilizing standard guide rails.
- Compact and Portable: Small size for convenient carrying and use in distribution boxes. Simple wiring for non-electricians.
- Wide Application Range: Suitable for high and low power distribution cabinets, factories, warehouses, companies, shopping malls, and homes.

3. Product Overview and Dimensions
The KWS-303 series meters are designed for single-phase AC power systems. They feature a clear LCD display and intuitive control buttons. The compact design allows for easy integration into electrical panels.

Key Components:

- N/L Terminals: Input and output connections for Neutral (N) and Live (L) wires.
- Display Screen: Shows all 8 electrical parameters.
- ON/OFF Button: Controls the switch status and navigates settings.
- '+' and '-' Buttons: Used for adjusting values and navigating menus.
- NTC Interface: For connecting the external temperature sensor.
- WiFi Icon (KWS-303WF): Indicates WiFi connection status.
- RS485 Interface (KWS-303L): For RS485 communication.
4. Specifications
| Parameter | KWS-303WF | KWS-303L | KWS-303 |
|---|---|---|---|
| Voltage Range | AC 85~290V | AC 85~290V | AC 85~290V |
| Current Range | 0~40A | 0~40A | 0~40A |
| Power Range | 0~12KW | 0~12KW | 0~12KW |
| Timing Range | 99 days | 99 days | 99 days |
| Energy Range | 0-9999Kwh | 0-9999Kwh | 0-9999Kwh |
| Temperature Range | -20~150°C | -20~150°C | -20~150°C |
| Frequency Range | 50-60HZ | 50-60HZ | 50-60HZ |
| Power Factor | 0.00-1.00PF | 0.00-1.00PF | 0.00-1.00PF |
| Power-off Memory | Yes | Yes | Yes |
| Under-voltage Protection | Yes | Yes | Yes |
| Over-voltage Protection | Yes | Yes | Yes |
| Over-temperature Protection | Yes | Yes | Yes |
| Timer Switch | Available in APP | No | No |
| Screen Brightness | Yes | Yes | Yes |
| Screen Rotation | Yes | Yes | Yes |
| Energy Reset | Yes | Yes | Yes |
| Reset Time | Yes | Yes | Yes |
| Wi-Fi | Yes | No | No |
| Curve Graph | Available in APP | Available in PC | No |
| 485 Communication | No | Yes | No |
5. Installation and Wiring
This product is suitable for indoor use and AC power systems. Ensure the wiring is connected correctly and does not exceed the specified measurement range for current and voltage.
5.1 DIN Rail Mounting
The KWS-303 series meters are designed for easy DIN rail mounting. Simply align the buckle with the 35mm DIN rail and snap it into place. No screws or additional fasteners are required.

5.2 Wiring Diagram
Always disconnect the power supply before wiring to avoid electric shock. Connect the Neutral (N) and Live (L) wires as shown in the diagram below. The input and output terminals are clearly marked.

Wiring Steps:
- Ensure the main power supply is OFF.
- Connect the incoming Live (L) wire to the 'L' input terminal and the incoming Neutral (N) wire to the 'N' input terminal.
- Connect the outgoing Live (L) wire to your load (e.g., fan, light bulb) from the 'L' output terminal.
- Connect the outgoing Neutral (N) wire to your load from the 'N' output terminal.
- If using the temperature sensor, connect it to the NTC interface.
- Double-check all connections for tightness and correctness before restoring power.
6. Operating Instructions
6.1 Basic Operation
Once powered on, the meter will display various electrical parameters on its TFT screen. The ON/OFF button controls the main switch status of the meter.
6.2 Accessing Settings
To enter the settings menu, press and hold the ON/OFF button for 5 seconds.

Settings Navigation:
- In the system settings page, use the '-' button to move the cursor to the desired option (e.g., "Over-voltage Protection").
- Press the ON/OFF button to select the option.
- Use the '+' or '-' buttons to adjust the value.
- Press the ON/OFF button again to save the adjusted value.
- To select other settings, press the '+' button to move to the next option.
- To exit the settings menu and return to the main screen, move the cursor to the "Exit" option using the '+' button and press ON/OFF.
Adjustable Settings:
- Under-voltage Protection
- Over-voltage Protection
- Over-current Protection
- Overload Protection
- Energy Protection
- Over-temperature Protection
- Power-on Behavior
- Screen Brightness
- Screen Timeout
- Screen Rotation
- Language Setting
- Auto Off
- Timer Off
- Reset Timer
- Clear Energy
- Factory Reset
6.3 APP Control (KWS-303WF only)
The KWS-303WF model supports remote control and monitoring via a mobile application.

APP Connection Steps:
- Step 1: Download the APP. Download the "Smart Life App" or "Tuya Smart App" from your mobile app store.
- Step 2: Connect to WiFi. On the meter's home screen, press and hold the '+' button until the WiFi icon in the top-right corner of the screen starts flashing.
- Step 3: Open Mobile APP. Open the downloaded mobile application and follow the in-app instructions to add and connect your KWS-303WF device.

The app allows you to view real-time data, set protection parameters, configure timed switches, and manage multiple devices.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Inspection: Periodically check wiring connections for tightness and signs of wear or damage.
- Environment: Ensure the device is used in a dry, indoor environment within the specified temperature range.
- Firmware Updates (KWS-303WF): Check the mobile application for any available firmware updates to ensure optimal performance and security.
8. Troubleshooting
- No Display/Power: Check the power supply and wiring connections. Ensure the input voltage is within the AC 85-290V range.
- Incorrect Readings: Verify that the current and voltage measurements do not exceed the calibration range. Recheck wiring for correct Live and Neutral connections.
- WiFi Connection Issues (KWS-303WF): Ensure the WiFi icon is flashing during pairing mode. Check your router's signal strength and ensure it's a 2.4GHz network. Restart the device and try pairing again.
- Device Malfunction: If the product exhibits any abnormal behavior, discontinue use immediately. Perform a factory reset if necessary (refer to section 6.2).
9. User Tips
- For accurate temperature readings, ensure the NTC sensor is properly installed and positioned to measure the desired temperature.
- Utilize the APP's timing functions (KWS-303WF) to automate power control for appliances, saving energy and enhancing convenience.
- Regularly review the energy consumption data through the app or on the device to identify patterns and optimize usage.
10. Safety Precautions

- Users should read and understand this instruction manual thoroughly and use the product in accordance with the instructions provided.
- During installation, the power supply must be disconnected before wiring to avoid the risk of electric shock.
- The product must be used according to the intended location and must not exceed the specified operating parameters.
- If the product exhibits any abnormal behavior, discontinue use immediately.
- Non-professional personnel should not use tools to disassemble the electrical device or alter the internal wiring.
11. Warranty and Support
Quality Assurance:
- A full warranty is provided for all products. If quality issues are found due to manufacturer responsibility, the product will be unconditionally replaced.
- The warranty period for products is one year from the date of purchase.
- The product must not be privately modified or disassembled, nor should it be used beyond its specified range of use.
- If the product is damaged due to human causes, free replacement, returns, or repair services are not offered. However, paid repair services may be available, with charges based on the extent of the damage.
For support or warranty claims, please contact your seller or refer to the product's purchase platform for specific service procedures.
A PDF version of this user manual is available for download: User Manual (PDF)