Congratulations on your new ANDELI product! This manual provides essential information for the safe and effective operation, installation, maintenance, and troubleshooting of your ANDELI MIG-135 3-in-1 Welding Machine. Please read this manual thoroughly before using the equipment to ensure your safety and to achieve optimal welding results.

The ANDELI MIG-135 is a versatile inverter welder designed for MIG, Lift TIG, and Stick (MMA) welding processes. It offers both automatic (Synergic) and manual control modes, making it suitable for both beginners and experienced professionals.

ANDELI MIG-135 3-in-1 Welding Machine

Figure 1: ANDELI MIG-135 3-in-1 Welding Machine

Video 1: Demonstration of the ANDELI MIG-135 welding machine in action, showcasing its capabilities for flux-cored, MMA, and Lift TIG welding.

1. Safety Information

Your safety is paramount. Always read and understand all safety precautions before installing, operating, or repairing this equipment. Failure to follow these instructions can result in serious personal injury or death.

General Warnings

  • ARC WELDING CAN BE HAZARDOUS. Protect yourself and others from possible serious injury or death. Keep children away.
  • PACEMAKER WEARERS should consult with their doctor before operating.
  • Ensure all installation, operation, maintenance, and repair procedures are performed only by qualified individuals.

Electric Shock Can Kill

  • The electrode and work (or ground) circuits are electrically "hot" when the welder is on. Do not touch these "hot" parts with bare skin or wet clothing.
  • Wear dry, hole-free gloves to insulate hands.
  • Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
  • In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment: Semiautomatic DC Constant Voltage (Wire) Welder, DC Manual (Stick) Welder, or AC Welder with Reduced Voltage Control.
  • In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically "hot".
  • Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
  • Ground the work or metal to be welded to a good electrical (earth) ground.
  • Maintain the electrode stinger, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
  • Never dip the electrode in water for cooling.
  • Never simultaneously touch electrically "hot" parts of electrode stingers connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
  • When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

Arc Rays Can Burn

  • Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding.
  • Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
  • Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

Fumes and Gases Can Be Dangerous

  • Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.
  • Keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone. When welding hardfacing or on lead or cadmium-plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
  • Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.
  • Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
  • Read and understand the manufacturer's instructions for this equipment and the consumables to be used, including the Safety Data Sheet (SDS) and follow your employer's safety practices. SDS forms are available from your welding distributor or from the manufacturer.

Welding and Cutting Sparks Can Cause Fire or Explosion

  • Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
  • Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been "cleaned".
  • Vent hollow castings or containers before heating, cutting or welding. They may explode.
  • Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
  • Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
  • Do not use a welding power source for pipe thawing.

Cylinder May Explode If Damaged

  • Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
  • Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
  • Cylinders should be located: Away from areas where they may be struck or subjected to physical damage. A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.
  • Never allow the electrode, electrode stinger or any other electrically "hot" parts to touch a cylinder.
  • Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
  • Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

Electric and Magnetic Fields May Be Dangerous

  • Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines.
  • EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
  • Exposure to EMF fields in welding may have other health effects which are now not known.
  • All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit: Route the electrode and work cables together - Secure them with tape when possible. Never coil the electrode lead around your body. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side. Connect the work cable to the workpiece as close as possible to the area being welded. Do not work next to welding power source.

2. Installation

Read the entire installation section before you start the installation. Only qualified personnel should perform this installation.

2.1 Select Suitable Location

Locate the MIG-135 in a dry place with free, clean air circulation to minimize dirt accumulation and prevent overheating. The machine should be placed on a secure, level surface or a recommended cart. Do not stack the MIG-135.

2.2 Controls and Operational Features

Control Panel Diagram

Figure 2: Control Panel Layout

  1. Diameter Button / 2T 4T Button: Used for switching welding wire diameter (0.8/0.9/1.0). Press for 3 seconds to enter/exit 2T/4T selection.
  2. LED Digital Display: Displays real-time data for current, voltage, wire feed speed, and other parameters.
  3. Inching Button: For manual wire feeding. Longer press increases speed.
  4. Voltage / Inductance Adjustment Knob: Rotates to adjust welding voltage and inductance. Long press for 3 seconds to enter inductance adjustment interface (FLUX mode only).
  5. Current Adjustment / Function Selection Knob: Press to select main mode (MMA/LIFT TIG/SYN). Rotate to adjust welding current.
  6. MIG Torch Socket
  7. Negative Output Terminal
  8. Control Switch Socket
  9. Positive Output Terminal
  10. Wire Spool Spindle and Brake
  11. Wire Feeder & Components

2.3 Installing the MIG Gun Assembly

Connect the standard gun to the Euro Torch Connector on the front of the welder. Make sure the gun connector is fully inserted into the wire drive system, then tighten the thumbscrew to secure it in place.

2.4 Gas Cylinder and Regulator Connection (for MIG welding)

For MIG welding, a separate gas cylinder (not included) is required. The gas hose connects from the machine's rear gas inlet to the regulator, which is then attached to the gas cylinder. The cylinder should be securely positioned in a well-ventilated area.

Setup Steps:

  1. Ensure the regulator valve is fully closed by turning the knob counterclockwise.
  2. Attach the gas regulator securely to the cylinder valve.
  3. Connect the gas hose from the regulator to the machine's gas inlet at the rear.
  4. Pull the MIG gun trigger to confirm that shielding gas flows through the gun.

WARNING: Cylinders are highly pressurized. Handle with care. Serious accidents can result from improper handling or misuse. Do not drop the cylinder, knock it over, and expose it to excessive heat, flames, or sparks. Do not strike it against other cylinders or strike an arc on it.

2.5 Installing the Welding Wire

WARNING: Ensure gas and electrical supplies are disconnected. Before proceeding, remove the nozzle and the contact tip from the gun.

WARNING: ELECTRIC SHOCK CAN KILL! Always turn the Power SWITCH OFF and unplug the welder's INPUT POWER CABLE from the AC power source before installing wire. When the gun trigger is depressed, the drive rolls, spool of wire, wire being fed, and electrode are all electrically live (hot).

Installing Spool:

  1. Open the access panel.
  2. Remove the nut, nut washer, spring, and spool spacer.
  3. Remove the outer wrapping from the spool of wire and find the leading end of the wire (do not unhook it yet).
  4. Place the spool on the WIRE SPOOL SPINDLE so that the wire unspools from the bottom, and the spool will rotate counterclockwise.
  5. Place the spool spacer, spring, nut washer and nut back.

Feeding Wire Through the MIG Gun:

  1. Trimming the Wire End: While holding the wire in place, use wire cutters to cut off the bent end of the wire, leaving only a straight end.
  2. Inserting the Wire and Operating the Drive Roller Pressure Arm: Hold the wire end and pull the pressure arm adjustment knob towards you to release the drive roller pressure arm. Lift the drive roller pressure arm away from the drive roller, then insert the leading end of the wire into the inlet guide tube. Push the wire across the drive roller and into the torch assembly for approximately 152.4MM.
  3. Aligning the Wire and Fixing the Pressure Arm: Align the wire in the inner groove of the drive roller, then let the drive roller pressure arm drop onto the drive roller. Pull the pressure arm adjustment knob back over the arm and turn it clockwise to tighten the pressure adjusting knob until the pressure roller applies enough force on the wire to prevent it from slipping out.
  4. Removing the Nozzle and the Contact Tip: Remove the nozzle and the contact tip from the end of the torch assembly.
  5. Connecting the Power and Adjusting the Panel Settings: Plug the welder's INPUT POWER CABLE into the AC power socket. Adjust the settings on the front panel according to the wire and workpiece sizes as per the setup chart on the inside door of the welding machine.
  6. Feeding the Wire Through the Torch and Checking: Pull the trigger on the MIG torch to feed the wire through the torch assembly. Check whether the drive roller is slipping on the wire and increase the pressure on the pressure arm adjustment knob if necessary. When at least 25.4MM of wire protrudes from the end of the torch, release the trigger.
  7. Installing the Contact Tip and the Nozzle: Slide the contact tip over the wire protruding from the end of the torch. Screw the contact tip into the end of the torch and tighten it firmly by hand. Install the nozzle on the torch assembly.
  8. Trimming the Excess Wire: Cut off the excess wire that extends beyond the end of the nozzle.
  9. Fine-Tuning the Wire Drive Pressure: Use the pressure arm adjustment knob to fine-tune the wire drive pressure. Turn the pressure adjustment knob clockwise to increase the driving pressure until the wire can be fed smoothly without slipping.
  10. Checking the Wire Feeding Pressure and Smoothness: When the driving pressure is set correctly, there should be no slippage between the wire and the drive roller. If an obstruction occurs, the wire should be able to slip on the drive roller.
ANDELI MIG-135 with included accessories

Figure 3: MIG-135 with included accessories

3. Operation

3.1 Performance Data and Duty Cycle

The duty cycle rating defines how long the operator can weld and how long the welding machine must rest and be cooled. It is expressed as a percentage of 10 minutes. For example, a 30% duty cycle at 90A means you can weld for 3 minutes out of every 10 minutes, with the remaining 7 minutes for cooling.

The MIG-135 features internal thermal protection. If you exceed the welding machine duty cycle, the thermal protection system will engage, shutting off all welding current output. After cooling, the thermal protector will automatically reset, and the welding functions can resume. The user needs to know it is the expected behavior of this machine. However, it would be best if you waited at least ten minutes after the thermal protector engages before resuming welding. You must do this even if the thermal protector resets itself before the ten minutes is up, or you may experience less than specified duty cycle performance.

3.2 Welding Preparation

Good preparation is key to a quality weld. Ensure your work area is organized, safe, well-lit, and free of flammables. Always protect your eyes and skin with appropriate gear.

WARNING: Exposure to a welding arc is extremely harmful to the eyes and skin. Prolonged exposure to a welding arc can cause blindness and burns. Never strike an arc or begin welding unless you are adequately protected. Wear fire resistant welding gloves, heavy long-sleeved shirt, cuffless pants; high topped shoes and a welding helmet.

3.3 Welding Wire Selection

This welder can work with gasless flux-cored wire with a diameter ranging from 0.8 mm to 1.0 mm.

3.4 Wire Feed Roller Selection

Select the appropriate K-groove roller based on the wire type and diameter to ensure smooth feeding and optimal performance.

TypeSizeSuitable Welding Wire
K-Groove Roller0.8/1.0mmE71-GS flux-core wire

3.5 Gas Selection

Select the appropriate shielding gas based on the material and welding process. Below is a brief introduction to the gas requirements for each mode:

ModeMaterialGas
MIG/MAG Pulse On/Dual PulseSteelNo Gas
Flux-coredSteelNo Gas
TIGStainless Steel100% Argon
StickSteelNo Gas

3.6 Setup for Home Menu

After powering on, the "Home Menu" will be lit. From this interface, you can choose the welding mode (Flux-cored Welding, TIG, Stick) and adjust basic settings. The machine will automatically return to the screen used prior to shut-down when restarted.

Home Menu Display

Figure 4: Home Menu Display with Two Control Modes (Automatic and Adjustment)

Each welding process features specific parameter icons on the screen. Refer to the "Welding Processes and Parameter Icon Reference Table" for a clear understanding of these settings.

ParameterSYNMANMMATIG
Diameter Selection√√√√
Torch Trigger Selection√√
Inductance√√
2T 4T√√

3.7 Flux-Cored (SYN) Welding Step

  1. Torch Installation: Insert the MIG torch into the MIG torch socket and screw in clockwise. Install the torch control switch onto the panel switch socket.
  2. Ground Clamp Installation: Connect the work clamp cord to positive (+) terminal.
  3. Welding Wire Installation: Install the welding wire (Section 2.5 for details), and then turn on the power switch.
  4. Mode Selection: Press the D knob to select SYN.
  5. Operation Instructions: Press the B button on the panel; the wire will feed automatically. Longer press increases speed. Alternatively, pull the torch trigger until the wire extends to the nozzle (nozzle may need to be removed).
  6. Wire Diameter Selection: Press the A button on 0.8/0.9/1.0.
  7. Set the Welding Current: Set the welding current with the D knob.
  8. Welding Technique Selection: Press the A Button for 3s to enter and exit the 2T/4T interface. Under 2T, the machine works after pressing the torch switch and stops when released. Under 4T, press once to start, release, current climbs, press again to finish, release.

The wire feeding speed and voltage are matched in a synergic manner. If not satisfied, use the C knob to adjust the voltage.

3.8 Flux-Cored (MAN) Welding Steps

The installation steps are consistent with the SYN mode.

  1. Wire Diameter Selection: Press the A button on 0.8/0.9/1.0.
  2. Welding Current: Set the welding current with the D knob.
  3. Welding Voltage: Set the welding voltage with the C knob.
  4. Welding Technique Selection: Press the A Button for 3s to enter and exit the 2T/4T interface, touch to select. Under 2T operation, the machine starts working after pressing the switch of torch, the machine stops welding when releasing the switch. Under 4T operation, press the button for the first time, it gives machine start-arc current, release the switch, current begins climbing to the normal welding current. Press the button again after the welding is finished, release the switch, machine stops working. Press the button 3 s again to exit.
  5. Inductance adjustment: If you want to adjust the arc hardness and softness. Press the C Knob for 3S to enter, rotate the knob to adjust the inductance value (-9.9 to +9.9), and press it again to exit.

3.9 Set up for Stick Welding (SMAW)

Basic Connections:

  1. Remove the Wire Drive Polarity Lead from the Positive (+) Output and Negative (-) Output Terminal (and MIG gun).
  2. Check the electrode packaging to determine the recommended polarity and connect the electrode holder and work clamp accordingly.
  3. Place the electrode into the electrode holder firmly.
  4. Ensure the work clamp has good contact with the workpiece on a clean, bare metal surface free of rust, paint, or coating.
  5. Turn the power source on and select the Stick welding process (MMA) with Function Knob on the Home Menu Page.
  6. Set the amperage with the Value Adjustment Knob.
  7. Strike the electrode against the workpiece to create an arc and hold the electrode steady to maintain the arc. Hold the electrode slightly above the work, maintaining the arc while traveling at an even speed.
  8. To finish the weld, break the arc by quickly snapping the electrode away from the workpiece. Wait for the weld to cool and carefully chip away the slag to reveal the weld metal below.

Polarity Setup for Stick Welding (SMAW):

DCEP (Direct Current Electrode Positive): Connect the electrode holder to the Positive (+) Output Terminal and the work clamp (connected to the workpiece) to the Negative (-) Output Terminal. Recommended for most stick welding applications, as it provides deeper penetration on thicker materials.

DCEN (Direct Current Electrode Negative): Connect the electrode holder to the Negative (-) Output Terminal and the work clamp to the Positive (+) Output Terminal. Recommended for welding thin metals or when required by specific electrode types.

ElectrodePolarityUsage
E7018, E4013, E6013DCEPThis electrode is best for use with clean, bare steel and is suitable for moderate penetration.
E4013, E6013DCENIt is applicable to typical American acidic electrodes. The deposited metal has good tensile strength and is suitable for all-position welding.

3.10 Set Up for Lift Arc TIG Welding (GTAW)

The TIG torch is not included with the machine. For optimal performance, the additional ANDELI WP-17V Lift TIG torch and Lanthanated Tungsten electrodes are recommended.

WARNING: TIG TORCH IS ALWAYS LIVE (ELECTRICALLY HOT). Use caution and ensure the TIG torch is not in contact or close to a conductive or grounded material.

Basic Connections:

  1. Remove the Wire Drive Polarity Lead from the Positive (+) Output and Negative (-) Output Terminals.
  2. Connect the TIG torch cable to the welder's Negative (-) Output Terminal.
  3. Connect the work cable connector to the welder's Positive (+) Output Terminal.
  4. Ensure the work clamp has good contact with the workpiece on a clean, bare metal surface free of rust, paint, or coating.
  5. Connect the TIG torch gas line to the gas regulator (use 100% Argon gas only). Turn on the gas at the regulator, check for gas flow, and adjust the flow rate as needed.
  6. Set the tungsten electrode to extend approximately 6.35MM from the gas cup. Ensure you are using the correct size and type of tungsten electrode. Smaller electrodes are suitable for lower welding currents. The tungsten must have a sharpened tip for direct current (DC) welding.

TIG Torch Assembling:

Assemble the TIG torch correctly to ensure proper shielding, arc stability, and optimal welding performance.

TIG Torch Assembly Diagram

Figure 5: TIG Torch Assembly Components

  1. Install the Collet Body: Thread the Collet Body into the Torch Head securely.
  2. Insert the Collet: Place the Collet inside the Collet Body. This holds the tungsten electrode.
  3. Insert the Tungsten Electrode: Insert the tungsten electrode through the Collet, leaving 3.2MM to 6.2MM of the electrode extending from the gas nozzle.
  4. Tighten with Back Cap: Screw the Back Cap onto the rear of the Torch Head to lock the tungsten electrode in place.
  5. Attach Insulator and Gas Nozzle: Place the Insulator Torch Body over the Torch Head to protect the assembly from heat. Thread the Ceramic Gas Nozzle onto the Collet Body for proper shielding gas coverage during welding.

TIG Electrodes Specification Reference Table:

MaterialThickness (inch/mm)Tungsten DiameterTungsten TypeFiller MetalCeramicGas Flow (CFH)Amperage Range (A)
Carbon Steel1/16"~1/8" (1.5~3.0mm)1.6mm (1/16")2% Thoriated (Red), 2% Lanthanated (Blue), 2% Ceriated (Gray)ER70S-6#5~#615~20 CFH20~135A
Stainless Steel1/16"~1/8" (1.5~3.0mm)1.6mm (1/16")2% Thoriated (Red), 2% Lanthanated (Blue), 2% Ceriated (Gray), Rare Earth (Purple)ER308/ER316#5~#615~20 CFH20~135A

4. Specifications

Specification Parameters Table

Figure 6: Specification Parameters

General Specifications
Model NumberMIG-135
Brand NameANDELI
CertificationCE
OriginMainland China
UseWelding
Dimensions330*150*238mm (12.99" x 5.91" x 9.37")
Weight4.1KG
Is Smart DeviceNo
High-concerned chemicalNone
Electrical Specifications
Standard Voltage / Frequency230V±10% 50/60Hz
Input Current (I1max)28A
Input Current (I1eff)12.5A
Open Circuit Voltage (U0)56V
Protection ClassIP21S
Insulation ClassF
CoolingAir-cool
Power Factor0.7
Efficiency≥80%
Rated Output - DC Only (230V)
ModeDuty CycleCurrentVolts at Rated Current
GMAW (MIG)20%135A20.8V
60%78A17.9V
100%60A17V
GTAW (TIG)20%135A15.4V
60%78A13.1V
100%60A12.4V
SMAW (STICK)20%135A25.4V
60%78A23.1V
100%60A22.4V
Temperature Range
Operating Temperature Range-10°C ~ +40°C (-14°F ~ 104°F)
Storage Temperature Range-20°C ~ +55°C (-4°F ~ 131°F)

5. Maintenance & Servicing

WARNING: DISCONNECT FROM POWER SOURCE WHEN CARRYING OUT THIS OPERATION. Always unplug the welder from its AC power source and wait several minutes for electrical energy to discharge before removing side panels.

5.1 General Maintenance

  • Keep the cabinet cover closed at all times unless the wire needs to be changed or the driving pressure needs adjusting.
  • Keep all consumables (contact tips, nozzles, and liner) clean and replace them when necessary.
  • Replace INPUT POWER CABLE, ground cable, work clamp, or gun assembly when damaged or worn.
  • Avoid directing grinding particles towards the welder. These conductive particles can build up inside the machine and cause severe damage.
  • Periodically clean dust, dirt, grease, etc. from your welder. Every six months or as necessary, remove the side panels from the welder and use compressed air to blowout any dust and dirt that may have accumulated inside the welder.
  • If available, use compressed air to clean the liner periodically, especially when changing wire spools.
  • Check all cables periodically. They must be in good condition and not cracked.

5.2 Consumable Maintenance

It is very important to maintain the consumables to avoid the need for premature replacement of the gun assembly.

Maintaining the Contact Tip:

  • The purpose of the CONTACT TIP is to transfer welding current to the welding wire while allowing the wire to pass through it smoothly.
  • Always use a contact tip stamped with the same diameter as the wire.
  • If the wire burns back into the contact tip, remove it from the gun and clean the hole running through it with an oxygen-acetylene torch tip cleaner or tip drill. If the burned-back wire cannot be removed, the contact tip must be replaced.
  • A failure mode of the contact tip is a worn-out hole with enlarged hole size. A worn-out contact tip usually results in unstable arc characteristics and difficult arc starting.

Caution: Keep the Gas Nozzle Clean!

  • During the welding, spatter and slag can build up inside the gas nozzle. The user must clean the gas nozzle periodically. Failure to clean and/or replace the gas nozzle in a timely fashion could cause damage to the front end of the gun assembly, which is not replaceable. The inaction results may require the replacement of the entire gun assembly.
  • If the spattering buildup inside the gas nozzle bridges the gas nozzle and the welding torch, it allows the welding current to pass through the gas nozzle beside the contact tip. This phenomenon causes erratic welds and less weld penetration. In addition, it leads to an overheating of the end of the welding gun and, in turn, damages the welding gun.

Testing for a Shorted Nozzle:

  • Arcing between the nozzle and the workpiece means the nozzle is shorted.
  • Unplug the AC power source, and use an ohmmeter to measure the resistance between the gas nozzle and the contact tip. If the resistance is not unlimited, the nozzle is shorted. Please clean or replace the gas nozzle.

6. Troubleshooting

This guide helps you locate and fix possible machine malfunctions. Follow the three-step procedure: 1. Locate Problem (Symptom), 2. Identify Possible Cause, 3. Follow Recommended Course of Action.

OBSERVE ALL SAFETY GUIDELINES DETAILED THROUGHOUT THIS MANUAL.

Error Codes and Solutions

  • E01: Indicates overheating. Welding is stopped because the main circuit of the machine gets overheated. No need to turn off the machine; wait a few minutes until the indicator turns off and the error code disappears.
  • E02: Indicates overcurrent. Restart the machine.

General Troubleshooting

ProblemPossible CauseCourse of Action
OVER HOTWelding current exceeds machine's capacityReduce welding current or contact support for assistance.
Machine is drawing too much amperage due to use of larger size electrode.Use a smaller electrode.
Frequent circuit breaker trips.Machine is not the only piece of electrical equipment on the circuit.Make sure the welder is on a dedicated circuit or is the only equipment plugged into a circuit.
Circuit breaker is incorrect/insufficient for use with this machine.Verify that the circuit breaker for the circuit is a 30A breaker for 120V and 20A for 240V. If it is not, have a qualified electrician install the proper breakers.
Screen's OFF, No output power, Fan not operating.No input power.Verify that circuit breaker has not been tripped in your main power panel. Reset if needed.
Wire loose connection.
POWER SWITCH is OFF.Ensure POWER SWITCH (rear) is in the ON position.
Screen is OFF, but fan is operating.Power supply issue.Check and secure power connections to display/control board.
Control board malfunction.Contact our support team for further assistance and repair.

MIG Welding Issues Troubleshooting

ProblemPossible CauseCourse of Action
No arc or wire feed. Screen's on, Fan operates normally.Gun trigger is not being pulled or is not making contact.Ensure the trigger is fully pulled. Inspect and replace the trigger switch if faulty.
Incorrect gun mode selected.Check and adjust the gun mode settings to match the correct gun type.
Exceeded duty cycle; thermal protection engaged.Allow the machine to cool down. Stay within the machine's duty cycle to avoid overheating.
Feed motor operates but wire will not feed.Wire Feed Motor Fault.Inspect the wire feed motor and connections. Replace if necessary.
Control Board Malfunction.Inspect the control board for damage. Contact our support team for further assistance and repair.
Wire feeds but no arc.Blocked or Worn Contact Tip.Clean or replace the contact tip. Ensure it's the right size for the wire.
Insufficient feed drive roller pressure.Adjust drive roller pressure.
Liner blocked or damaged.Clear with compressed air or replace liner.

Lift TIG Welding Issues Troubleshooting

ProblemPossible CauseCourse of Action
Poor starting.Poor work clamp connection.Check and secure work connection.
Black area along weld bead.Contaminated base metal.Remove materials like paint, grease, oil, and dirt, including mill scale from base metal.
Tungsten is contaminated.Remove 10MM of contaminated tungsten and re-grind the tungsten.
Unstable Arc.Insufficient gas shielding.Check and set the gas flow between 0.57~0.85M³ flow rate.
Contaminated gas or leaks in gas line, torch, or connections.Check gas line & connections.

Stick Welding Issues Troubleshooting

ProblemPossible CauseCourse of Action
Poor starting.Poor work clamp connection.Check and secure work connection.
Electrode "stick" in weld puddle.Current may be set too low for electrode size.Adjust current.
Damp electrode.Use dry electrode.
Porosity - small cavities or holes.Workpiece dirty.Remove all grease, oil, moisture, rust, paint, coatings, slag, and dirt from work surface before welding.
Amperage too high for electrode.Decrease amperage or select larger electrode.
Incomplete Fusion.Improper welding technique.Place stringer bead in proper location at joint during welding.
Workpiece dirty.Remove all grease, oil, moisture, rust, paint, coatings, slag, and dirt from work surface before welding.
Lack Of Penetration.Improper joint preparation.Material too thick. Joint preparation and design must provide access to bottom of groove.
Improper weld technique.Keep arc on leading edge of weld puddle. Increase amperage. Select larger electrode and increase amperage.
Burn Through.Excessive heat input.Select lower amperage. Use smaller electrode.

7. Wiring Diagram

For qualified technicians, the internal wiring diagram provides a detailed overview of the machine's electrical connections.

ANDELI MIG-135 Wiring Diagram

Figure 7: Internal Wiring Diagram (JK-ZJJXT-MIG-135-90*50LED-220V-A0)

8. User Tips

  • Start with Automatic Mode: For beginners, the automatic (Synergic) mode in MIG welding is highly recommended as it automatically matches current and voltage, simplifying the setup process.
  • Practice on Scrap Metal: Before working on your main project, always practice on similar scrap metal to fine-tune your settings and technique.
  • Keep Consumables Clean: Regularly clean contact tips, nozzles, and liners to ensure consistent wire feeding and arc stability. Replace them when worn.
  • Proper Ventilation is Key: Always ensure adequate ventilation to disperse welding fumes and gases, especially in enclosed spaces.
  • Check Connections: Before each use, verify that all electrical connections (work clamp, gun, power cable) are secure and clean to prevent issues like poor arc starting or overheating.

9. Warranty and Support

ANDELI products are designed for quality and affordability. For further questions or support, please refer to the contact information below.

  • Official Website: www.andelitools.com
  • After-sales Email: support@andeligroup.com
  • After-sales Number (USA): +1 949 617 9002
  • After-sales Number (Hong Kong): +852 8480 7265
  • User Manual (PDF): A detailed user manual in PDF format can be found here.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.