1. Product Overview

The JIKONG Lithium battery intelligent protection board (BMS) is a management system designed for large capacity series lithium battery packs. It features voltage acquisition, current active balancing, overcharge, over-temperature protection, a coulomb meter, and Bluetooth communication. This BMS is compatible with various battery types including lithium iron phosphate (LiFePO4), ternary lithium (Li-ion), lithium titanate (LTO), and sodium batteries.

The protection board utilizes energy transfer active balancing technology, which is proprietary to JIKONG. This technology enables a maximum continuous balancing current of 0.6A. Active equalization ensures battery consistency, extends battery life, and delays aging.

The BMS is small in size, simple to operate, and fully functional, making it suitable for a wide range of applications such as small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

JIKONG JKBMS JK-BD6A24S6PD with key features

Figure 1: JIKONG JKBMS JK-BD6A24S6PD highlighting key features.

JIKONG JKBMS JK-BD6A24S6PD product components

Figure 2: JKBMS package contents including the BMS unit, wiring harness, NTC sensor, and mounting screws.

2. Functional Characteristics

  • LED Bluetooth Status Indicator: Provides visual feedback on Bluetooth connection status.
  • APP Bluetooth Remote Operation: Control and monitor the BMS via a mobile application.
  • Battery Capacity Calculation: Accurately estimates remaining battery capacity.
  • High Precision Voltage Acquisition (±3mV): Ensures accurate cell voltage monitoring.
  • High Precision Current Acquisition: Monitors charge and discharge currents precisely.
  • Accurate Time Logging: Records operational data over time.
  • One-wire (Optional): Supports single-wire communication.
  • LED Battery Level Display (Optional): Visual indication of battery charge level.
  • UART Communication Support: For data exchange with external devices.
  • Comprehensive Protection Functions:
    • Charge Overcurrent Protection
    • Charge Overvoltage Protection
    • Charge Over Temperature Protection
    • Low Temperature Protection During Charge
    • Discharge Overcurrent Protection
    • Discharge Undervoltage Protection
    • Discharge Over Temperature Protection
    • Short Circuit Protection

3. Package Contents

The standard package includes the following items:

  • 1 x BMS Unit
  • 1 x Sampling Line (70cm long)
  • 1 x NTC Temperature Sensor (40cm long)
  • 1 x Switch Key (50cm long)
Packing list for JIKONG JKBMS

Figure 3: Visual representation of the JKBMS packing list.

4. Specifications

4.1. General Parameters

ParameterValueUnit
Supply Voltage20-100V
Operating Power Consumption<800mW
Operating Temperature-30 to 70°C
Max. Number of Collection Strings24Strings
Max. Balancing Current0.6A
Max. Instantaneous Current120A
Max. Internal Loop Resistance1.1mΩ
Protective Plate Size116.8*94.8*14.6mm
Finished Weight327g

4.2. Model-Specific Parameters

ModelActive Equalizing CurrentMax. Charging CurrentMax. Discharge Current
JK-B1A8S10P1A100A100A
JK-B1A8S20P1A200A200A
JK-B2A8S20P2A200A200A
JK-B2A8S30P2A300A300A

4.3. Default Parameters (Excerpt)

ParameterLi-ion DefaultLiFePO4 DefaultLTO DefaultUnit
Balancing Initial Voltage332V
Maximum Balancing Current0.60.60.6A
Unit Overcharge Voltage4.23.62.7V
Single Overcharge Protection Recovery4.183.552.65V
Monomer Undervoltage Protection2.822.61.8V
Single Undervoltage Protection Recovery2.852.651.85V
Automatic Shutdown Voltage2.82.51.7V
SOC-0% Voltage2.92.61.85V
SOC-100% Voltage4.183.52.65V
Trigger Balancing Differential Pressure0.010.010.01V
Charge Overcurrent Protection Delay303030S
Charge Overcurrent Protection Release Time606060S
Discharge Overcurrent Protection Delay300300300S
Discharge Overcurrent Protection Release Time606060S
Short-circuit Protection Delay555uS
Charging Overtemperature Protection707070°C
Charging Overtemperature Recovery606060°C
Discharge Overtemperature Protection707070°C
Discharge Overtemperature Recovery606060°C
Charging Low Temperature Protection-20-20-20°C
Charging Low Temperature Recovery-10-10-10°C
MOS Overtemperature Protection100100100°C
MOS Overtemperature Recovery808080°C

5. Setup and Installation

5.1. Product Appearance and Interfaces

The JKBMS features a robust aluminum alloy shell designed for superior heat dissipation and protection against environmental damage. It incorporates selected core components and a high-performance MCU for efficient operation.

Aluminum alloy shell for heat dissipation

Figure 4: Exploded view showing the aluminum alloy shell and internal components for heat dissipation.

Aluminum alloy shell for protection

Figure 5: The robust aluminum alloy shell protects electronic components from external damage.

Selected core components of the BMS

Figure 6: Close-up of the BMS circuit board highlighting the featured MCU and other core components.

5.2. Wiring Instructions

The JK-BD6A24S-4PD series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all cables are connected correctly and securely inserted into the BMS.

General Steps:

  1. Connect all balance cables to the battery cells.
  2. Insert the balance cable into the BMS connector.
  3. Connect the B- line (total negative electrode) and the P- line (total positive electrode) to the battery.
Wiring diagram for 8-string cells

Figure 7: Wiring diagram for an 8-string cell configuration. Connect B- to the total negative electrode and P- to the total positive electrode. Balance wires connect from B1 to B8.

Wiring diagram for 4-string cells

Figure 8: Wiring diagram for a 4-string cell configuration. Similar connection principles apply for B- and P-.

5.3. Device Activation

Before powering on the protection board, ensure the balance cable is properly connected and that the P- and B- connections are correct. Verify that the protection board is securely fixed to the battery core. Incorrect connections can lead to malfunctions or damage.

The protection board does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After assembling the battery, connect the charger to activate the protection board.

Alternatively, if you have opted for the light panel, you can activate the device by inserting the cable into the light panel interface and pressing the button.

6. Operating Instructions

6.1. APP Installation and Usage

The protection board features a mobile APP compatible with Android and iOS operating systems. The APP allows you to connect to the BMS via Bluetooth to monitor battery status, modify parameters, and control charge/discharge switches.

To install the APP, scan the QR code below. An Android version 7 or higher is required.

QR code for JIKONG BMS APP download

Figure 9: Scan this QR code to download the JIKONG BMS mobile application.

Once installed, connect the APP to the BMS via Bluetooth. The APP provides a multi-interface display for real-time data such as voltage, current, temperature, SOC (State of Charge), alarms, and cycle counts.

Multi-interface display and data connection via APP and PC software

Figure 10: The mobile APP and PC software interfaces for monitoring and controlling the BMS.

6.2. Active Equalization

The BMS employs active equalization technology to transfer energy from higher-voltage cells to lower-voltage cells, ensuring voltage balance. Before using this function, set the battery type and basic parameters (number of cells, capacity, trigger equalization differential pressure, voltage calibration, current calibration) in the APP.

You can set the balance trigger pressure difference (mV) in the APP. When the balance is enabled, it automatically activates if the voltage difference between any two battery strings exceeds the set value, and deactivates when the difference falls below the set value. The default balance current is 0.6A, which can be adjusted based on battery capacity. If not needed, the balancing function can be switched off in the BMS control page of the APP.

Active Balancing (Lossless Balancing) diagram

Figure 11: Diagram illustrating the principle of active balancing, transferring energy between cells.

Table showing balance effect comparison

Figure 12: Comparison of cell voltage differences before and after active balancing for a 16-section 100AH battery.

6.3. LED Battery Level Display

The BMS supports an optional LED power level display panel. The panel has an activation switch to turn the display on or off. Refer to the table below for the correspondence between SOC and LED indicators:

SOCLED1LED2LED3LED4LED5
0%~9%●○○○○
10%~19%●●○○○
20%~39%●●●○○
40%~59%●●●●○
60%~79%●●●●●
80%~100%●●●●●

Note: ● indicates Green (always on), ○ indicates Off.

7. Maintenance

The JIKONG BMS is designed for durability and reliability, incorporating various protection features to maintain battery health. Regular monitoring through the mobile APP is recommended to ensure optimal performance and identify any potential issues early.

The aluminum alloy casing provides robust protection and efficient heat dissipation, contributing to the longevity of the device. No specific routine maintenance is required beyond ensuring clean connections and proper operating temperatures.

8. Troubleshooting

8.1. Overvoltage/Undervoltage Protection and Recovery

The BMS includes standard charge overvoltage and discharge undervoltage protection. Users can set specific voltage thresholds in the APP. If a cell's voltage exceeds the overvoltage threshold during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the recovery threshold. Similarly, if a cell's voltage falls below the undervoltage threshold during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery threshold.

8.2. Overcurrent Protection and Recovery

The BMS is equipped with charge and discharge overcurrent protection. Users can set continuous current limits and delay/release times in the APP. If the current exceeds the set limit for the specified delay, the BMS will trigger protection and stop the operation. The operation will resume after the overcurrent release time has passed.

Note: The maximum continuous discharge current should not exceed 60A for this model.

8.3. Overtemperature/Low Temperature Protection and Recovery

The BMS features charge/discharge overtemperature and charge low temperature protection. Users can set temperature thresholds in the APP. If the temperature exceeds the overtemperature limit or falls below the low temperature limit, the BMS will stop the respective operation. Operations resume when temperatures return to safe levels.

8.4. Short Circuit Protection and Recovery

Short circuit protection is standard. While the trigger current is not user-adjustable, delay and recovery times can be set in the APP. If a short circuit occurs, the BMS will protect the system. If a short circuit is triggered upon initial connection of a charger or load, increasing the short circuit protection delay may resolve the issue, especially if the charger has a high peak current or the load has large capacitance.

8.5. Emergency Switch

In situations like over-temperature, over-discharge, over-charge, or cell string issues during normal use, activating the emergency switch in the APP will enable both charging and discharging for 30 minutes. This provides a temporary operational window, even if a single cell reaches automatic shutdown voltage, to prevent critical failures like being stranded.

8.6. Intelligent Sleep

The intelligent sleep function allows the BMS to enter a low-power state if the charging and discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's energy consumption from the battery. The device can be reactivated by pressing a button (if a light panel is installed) or by connecting a charger.

9. User Tips

  • Always double-check all wiring connections, especially balance leads and main power lines (B- and P-), before activating the BMS to prevent damage.
  • Utilize the mobile APP for real-time monitoring of cell voltages, temperatures, and currents to ensure optimal battery health and performance.
  • Customize protection parameters in the APP according to your specific battery chemistry and application requirements for enhanced safety and longevity.
  • If experiencing unexpected shutdowns, review the troubleshooting section and check APP logs for protection triggers. Adjust delay/recovery times if necessary, especially for short-circuit protection with high-peak current chargers or capacitive loads.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact JIKONG Official Store directly. Keep your purchase records for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.