Komshine QX43

Komshine QX43 FTTx OTDR Instruction Manual

Model: QX43

1. Introduction

The Komshine QX43 FTTx OTDR is a versatile Optical Time Domain Reflectometer designed for comprehensive fiber optic network installation, maintenance, and troubleshooting. It features a 4.3-inch capacitive touch screen, multiple integrated functions including Optical Power Meter (OPM), Visual Fault Locator (VFL), Optical Light Source (OLS), and RJ45 network test module. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your QX43 device.

Komshine QX43 FTTx OTDR device with key features highlighted
Figure 1: Komshine QX43 FTTx OTDR with key features: Multi-function, 4.3-inch capacitive touch screen, ≤1.5m low event blind zone, dynamic range ≤31dB, 6000mAh large capacity battery, and 3 years warranty.

2. Setup

2.1. Unpacking and Initial Inspection

Upon receiving your Komshine QX43, carefully unpack all components and inspect for any signs of damage. Ensure all items listed in the 'Product Configuration' are present.

Komshine QX43 FTTx OTDR product configuration
Figure 2: Product Configuration. Includes: (1) Carrying bag, (2) OTDR (default SC interface), (3) Power cord, (4) FC optical port converter, (5) Screwdriver, (6) RJ45 module, (7) Sterile cotton swabs, (8) Shoulder strap, (9) Quick guide, Calibration certificate, Test report.

2.2. Powering On/Off

  1. To power on the device, press and hold the power button for 3 seconds.
  2. To power off, press and hold the power button again until the device shuts down.

2.3. Charging the Device

The QX43 features a Type-C charging interface, compatible with most mainstream mobile phone/notebook chargers. Connect the provided power cord to the Type-C port on the device and plug it into a power source. The charging indicator will show the charging status.

Komshine QX43 FTTx OTDR Type-C charging
Figure 3: Type-C charging port for multi-purpose compatibility.

2.4. Interface Connections

The device is equipped with various interfaces for different functions:

  • Type-C interface: For charging.
  • USB 2.0: For data transfer and software upgrades.
  • RJ45: For network cable testing.
  • OTDR/light: Optical fiber interface for OTDR and Stable Light Source (SLS) functions.
  • VFL: Visual Fault Locator port.
  • OPM: Optical Power Meter port.
Komshine QX43 FTTx OTDR rear view with interfaces labeled
Figure 4: Rear view of the QX43 showing Type-C, RJ45, USB, OTDR/light, VFL, and OPM interfaces.

2.5. Universal Interface Adapters

The QX43 supports replaceable universal interface design, allowing for the use of SC, FC, and ST adapters. The default interface is SC. Use the provided FC optical port converter if needed.

Komshine QX43 FTTx OTDR showing replaceable universal interface design
Figure 5: Replaceable universal interface design supports FC (standard), ST (optional), and SC (optional) adapters.

3. Operating Instructions

3.1. User Interface and Navigation

The QX43 features a 4.3-inch capacitive touch screen with clear screen colors and a concise interface. It supports zoom in/out functions and allows for easy cursor movement on the OTDR curve for detailed analysis.

Komshine QX43 FTTx OTDR with 4.3-inch capacitive touch screen showing zoom and cursor movement
Figure 6: The 4.3-inch capacitive touch screen supports zoom in/out and cursor movement for detailed OTDR curve analysis.

3.2. OTDR Module Operation

The OTDR module is used for optical fiber event and loss testing. The device can perform an 8-segment 3-meter jumper test in fully automatic mode, making it an industry benchmark for FTTx OTDR.

  1. From the main menu, click to enter the OTDR module.
  2. Select the desired wavelength (e.g., 1310 nm or 1550 nm).
  3. Choose the measurement mode (e.g., Average).
  4. Ensure Time, Range, and Pulse Width settings are appropriate, or set them to automatic.
  5. Initiate one-click testing. The test results, including the OTDR curve and event list, will be displayed clearly and accurately.
Video 1: Demonstration of the 8-segment 3-meter jumper test on the QX43 OTDR, showing power-on, module selection, wavelength and mode settings, one-click testing, and viewing results.
Komshine QX43 FTTx OTDR showing auto mode measurement results
Figure 7: Auto Mode measurement displaying continuous 8x3m optical fiber event with accurate test results for fiber events and losses.

3.3. Smart Map Graphical Links

The Smart Map feature provides a graphical representation of OTDR test results, intuitively displaying optical fiber loss, breakpoints, and fault locations. This allows for clear understanding of optical fiber link status at a glance, improving detection efficiency and maintenance accuracy.

Komshine QX43 FTTx OTDR showing Smart Map Graphical Links
Figure 8: Smart Map Graphical Links provide an intuitive display of optical fiber loss, breakpoints, and fault locations.

3.4. Multi-function Capabilities

The QX43 integrates several essential functions for fiber optic testing:

  • Optical Power Meter (OPM): Measures absolute optical power or relative loss of optical fiber.
  • Visual Fault Locator (VFL): A visual light source used for fault location and fiber identification.
  • Stable Light Source (SLS): Outputs stable continuous light to the optical system, used in combination with an optical power meter to measure optical loss.
  • RJ45 Network Test Module: For network sequencing and network line hunting, suitable for LAN fault detection, maintenance, and integrated wiring construction.
Komshine QX43 FTTx OTDR showing various functions: OTDR, OPM+VFL, SLS, and RJ45 Network Test Module
Figure 9: The QX43 offers multiple functions including OTDR, OPM+VFL, SLS, and RJ45 Network Test Module.

3.5. Data Management

The built-in post-processing software allows saving OTDR measurement results as general SOR format files, capable of storing over 1,000 files. These files can be viewed on a host computer.

Komshine QX43 FTTx OTDR connected to a laptop, illustrating SOR file saving and host computer viewing
Figure 10: The QX43 can save SOR format files and supports host computer viewing for detailed analysis and record-keeping.

3.6. Illumination Lamp

The device includes a high-brightness illumination lamp, which is convenient for line inspection and construction in dim environments.

Komshine QX43 FTTx OTDR showing the lighting lamp feature
Figure 11: The built-in lighting lamp makes working in dim environments easier.

4. Maintenance

4.1. Connector Replacement

The QX43 supports independent connector replacement. This feature helps reduce return-to-factory service costs and downtime, ensuring long-term optimal performance. Use the provided screwdriver for replacement.

Komshine QX43 FTTx OTDR with its bracket and showing independent connector replacement
Figure 12: The bracket provides stable support, and the device supports independent connector replacement.

4.2. Cleaning and Care

  • Keep the device clean and free from dust and debris. Use sterile cotton swabs (included in the package) for cleaning optical interfaces.
  • Store the device in its carrying bag when not in use to protect it from physical damage.
  • Avoid exposing the device to extreme temperatures or humidity.

4.3. Software Upgrade

The device supports USB data transfer and software upgrades. Connect the QX43 to a computer via the USB port to manage data or update the firmware.

Komshine QX43 FTTx OTDR connected via USB for data transfer and software upgrade
Figure 13: USB port for data transfer and software upgrades.

5. Troubleshooting

The Komshine QX43 is designed to assist in identifying and troubleshooting issues in fiber optic networks. Its intelligent curve analysis accurately records every event, helping users understand losses from optical cable breaks, lengths, bends, fusion points, and connectors through detailed OTDR curves.

  • No Power: Ensure the device is fully charged. If not, connect it to a power source using the Type-C cable.
  • Inaccurate Readings: Check that the optical fiber interfaces are clean. Use sterile cotton swabs to clean them. Verify that the correct wavelength and measurement mode are selected for your test.
  • Connection Issues: For RJ45 tests, ensure the network cable is properly connected. For optical tests, ensure the fiber connectors are securely seated and the correct adapter type (SC/FC/ST) is used.
  • Software Glitches: If the device behaves unexpectedly, try restarting it. If the issue persists, consider performing a software upgrade via the USB port.

6. Specifications

6.1. General Parameters

ParameterValue
Link diagram
Pass/Fail displayx
Distance unitkm
PC side analysis software
LanguageEnglish, Chinese, Spanish, French, Portuguese, Russian, Thai, Korean
Optical fiber interfaceFC/UPC (SC/UPC optional)
Display screen4.3-inch color LCD screen (resolution: 800x480)
InterfaceType-C charging interface x1, USB 2.0 x1, RJ45 x1
Operating temperature-10-50 °C (0-40 °C connected to power supply, 0 to 35 °C battery charge)
Storage temperature-20 to 60 °C
Elevation4000 m
Humidity0 to 90% RH (at: 20%-90% 739874 AC adapter, no frost)
Power supply mode100-240V AC, 50/60 Hz (AC adapter)
Battery3.7V, 6000mAh, ≥22Wh
Illumination lampLight intensity ≥ 15000 mcd
Working hours5 hours
Data StorageMemory: ≥ 1000 test curve; External storage: USB
Dimensions179 mm (W) × 112 mm (H) × 48 mm (D)
Weight0.6 kg (mainframe only with battery)

Figure 14: General Parameters for Komshine QX43 FTTx OTDR.

6.2. VFL, OPM, and SLS Specifications

ModuleSpecification
VFLRed light source module (built-in function)
Wavelength (nm)650
Output power10mW
Modulation modeCW, CHOP (2 Hz)
Laser safety ratingClass 3R
Optical fiber interface2.5 mm universal connector for FC, SC, ST
OPMOptical power meter module (built-in function)
Measurement wavelength range800~1650nm
Correction wavelength (nm)850, 1300, 1310, 1490, 1550, 1625, 1650
Measurement power range-70~6dBm
Measurement accuracy< (±0.2dB or ±5%)
SLSStable Light Source Module (built-in function)
Wavelength (nm)1310/1550, 1550, 1610, 1577, 1625, 1650
Output power≥-10dBm
Modulation frequencyCW, 270Hz, 1kHz, 2kHz
Laser safety ratingClass 1M or Class 1
Built-in optical fiber interfaceOTDR optical port

Figure 15: VFL, OPM, and SLS Specifications.

6.3. RJ45 Specifications

ModuleSpecification
RJ45Network test module (built-in function)
Applicable network cableCAT5, CAT6
Alignment length300m
Maximum audio transmission distance300m

Figure 16: RJ45 Network Test Module Specifications.

6.4. OTDR Specifications (QX43 Models)

ParameterModel
QX43 S1QX43 S2QX43 P1QX43 P2QX43 D1QX43 D2QX43 D3QX43 D4QX43 D5
Wavelength (nm)1310/15501310/15501310/1550/1625±201310/1550/1650±2015501610157716251650
Dynamic range (dB)26/2431/2926/24/2426/24/242424242424
Event blind spot (m) ①≤1.5
Attenuation blind zone (m) ②≤5
Number of fiber interfaces1 FC/UPC2 FC/UPC1 FC/UPC
Applicable optical fiberSMSM-LiveSM
Range (Km)0.5, 1, 2, 5, 10, 20, 35, 50, 75, 100, 150
Distance accuracy (m)± (1m + measurement distance × 2 × 10⁻⁵ + collection point resolution)
Pulse width (ns)5, 10, 20, 50, 100, 200, 500, 1000, 2000, 10000, 20000
Number of sampling points≥15000
Sampling resolution (m)0.04
Loss accuracy0.03dB/dB
Reflection accuracy±2dB

Figure 17: OTDR Specifications for various QX43 models.

7. User Tips

  • Always ensure optical connectors are clean before use to prevent inaccurate readings and potential damage.
  • Utilize the Smart Map feature for a quick and intuitive overview of fiber link health.
  • Take advantage of the 6000mAh large capacity battery for extended field work, but remember to charge it fully before critical tasks.
  • For complex troubleshooting, save SOR files and analyze them on a larger computer screen for more detailed inspection.

8. Warranty and Support

The Komshine QX43 FTTx OTDR comes with a 3-year warranty, ensuring reliability and peace of mind. For technical support, service, or warranty claims, please refer to the contact information provided with your purchase documentation or visit the official Komshine website.

Related Documents - QX43

Preview Komshine QX43 FTTx-OTDR Quick Guide - Optical Time-Domain Reflectometer
Concise guide to the Komshine QX43 FTTx-OTDR, covering its features, test setup, curve manipulation, event list, file management, and event type meanings for optical fiber testing.
Preview KLS-35 Stable Light Source Instruction Manual - Komshine
Comprehensive instruction manual for the Komshine KLS-35 stable fiber optic light source. Covers device functions, power-saving settings, backlight control, wavelength and carrier selection, LED flashlight, product introduction, features, detailed specifications, usage environment, important tips, standard kit contents, and contact information for Komshine Technologies Limited. Ideal for FTTX network and fiber optic testing.
Preview Komshine FX39 Fiber Optic Fusion Splicer: Features, Specs, and Performance
Explore the Komshine FX39, a high-performance fiber optic fusion splicer. Discover its rapid splicing (6s), low loss (0.01dB), durable design, 7800mAh battery, and advanced alignment technologies.
Preview Komshine KLS-35 Stable Light Source: User Manual and Specifications
Comprehensive instruction manual for the Komshine KLS-35 stable light source, detailing its features, specifications, operation, and safety guidelines for fiber optic testing.
Preview Komshine KFI-35 Optical Fiber Identifier User Manual
User manual for the Komshine KFI-35 Optical Fiber Identifier, detailing its features, product parameters, usage instructions, and safety tips for fiber maintenance.
Preview Komshine KPM-35 Optical Power Meter User Manual
Comprehensive user manual for the Komshine KPM-35 Optical Power Meter, covering its features, functions, calibration, troubleshooting, product parameters, and usage tips for optical fiber network projects.