1. Introduction
This instrument utilizes a new LED light source that flickers at a specific frequency. It is designed for observing objects rotating or moving at high speeds. By adjusting the flickering frequency of the LED light, the instrument can synchronize with the object's speed, making the high-speed object appear to move slowly or even stand still. This allows for inspection of the surface quality or running state of the object.
The stroboscope uses the newest imported LED as its light source, offering high brightness, long life, and reliable triggering compared to traditional xenon lamps. It incorporates advanced digital frequency synthesis techniques for accurate, stable, and reliable flicker frequency output. A 360° rotary driving plate and a multiplying power gear switch facilitate strobe output adjustment. The rotary dial allows for quick or slow adjustment of the strobe speed, enhancing convenience for numerical value changes. An LCD provides clear display information.
The instrument's compact and lightweight design makes it easy to carry and handle. Its non-contact measurement method simplifies operation and makes it practical for various applications. It is particularly suitable for measuring the rotational speed of motors, fans, pumps, and gears, inspecting product quality on high-speed production lines, and diagnosing product vibration issues. Applications include HVAC, printing, papermaking, textile, medicine, light industry, and machining.
2. Product Overview
The SWEVY LED Stroboscope is a portable, handheld device designed for non-contact speed measurement. It features an intuitive interface with a display screen, control buttons, and a rotary dial for precise adjustments.
2.1. Components and Controls (SW6500)
- LED Strobe Projecting Light Source
- Display Screen
- Strobe Rate Increment Digital Multiplier / Clear Button (X)
- On/Off (Power Button)
- Phase Adjustment Button (C)
- Strobe Rate Adjustment Rotary Dial
2.2. Components and Controls (SW6800)
- LED Strobe Projecting Light Source
- Color Display Screen
- M Mode Switch Key
- Phase Adjustment Button
- X Strobe Rate / Clear Button
- Power Switch
- Strobe Rate Adjustment Rotary Dial
2.3. Components and Controls (SW6900)
- LED Strobe Projecting Light Source
- Color Display Screen
- M Mode Switch Key
- S Phase Adjustment Button
- X Strobe Rate / Clear Button
- Strobe Rate Adjustment Rotary Dial
3. Specifications
The SWEVY LED Stroboscope models offer varying features and performance. Key specifications are detailed below:
| Feature | SW6500 | SW6800 | SW6900 |
|---|---|---|---|
| Measuring Range | 500-49999 flashes/min | 500-99999 flashes/min | 500-999999 flashes/min |
| Accuracy | 0.001% | 0.001% | 0.001% |
| Illumination | 750 LUX | 1500 LUX | 1500 LUX |
| Sensor (Light) | 3 lights | 16 lights | 9 lights |
| Power Supply | 2200mA lithium battery | 2200mA lithium battery | 2200mA lithium battery |
| Function Dial | 360 degree turntable | 360 degree turntable | 360 degree turntable |
| Size | 210*90*57 mm | 210*90*57 mm | 210*90*57 mm |
| Mode Switching | Speed | Speed/frequency/brightness | Speed/frequency/brightness, data can be stored |
3.1. General Technical Parameters
- Measurement Range: 60-99999 RPM
- Accuracy: 0.001%
- Illuminance: 750 LUX (SW6500), 1500 LUX (SW6800, SW6900)
- Display: LCD display (SW6500), Color LCD display (SW6800, SW6900)
- Power Source: 7.4V / 1100 mA lithium battery
- Power Consumption: Working ≤0.2 W
- Continuous Working Time: 8 hours
- Standby Time: 3 months
- Operating Temperature: -10°C to 55°C
- Overall Dimension: 210 X 90 X 57 (mm)
- Weight: 320g (including battery)
- Battery Included: Yes
- Semi-finished product: No
- High-concerned chemical: None
- Certification: CE, RoHS
4. Setup
4.1. Initial Charging
The instrument is powered by a built-in lithium battery. For the first use, fully charge the instrument. It is recommended to fully charge and discharge the battery several times to optimize its capacity and service life. Connect the instrument to a USB power source using a standard USB data cable. The charging plug needs to be purchased separately.
When fully charged, the battery indicator on the LCD display will show full (4 grids). If the indicator shows empty, the power is insufficient, and the instrument should be charged promptly. Overcharging for extended periods can affect battery life.
4.2. Powering On/Off
Press the power button (usually marked with a power symbol) to turn on the instrument. Press it again to turn off the instrument. The device will retain the last measured rotate speed in its memory when turned off.
5. Operating Instructions
The instrument features an LCD display, three buttons (Power, Phase, Multiplier/Reset), and an adjustment plate (rotary dial) on the front surface.
5.1. Display Information
The display shows the current rotate speed (FPM/RPM), multiplying power (X1, X10, X100), and battery charge indication.
5.2. Button Functions
- Power Button: Press to turn the instrument on or off. The last rotate speed is saved.
- Phase Button: Press for clockwise rotation at a certain angle of the object. Long press and hold for clockwise rotation at low speed to observe working conditions from different angles.
- Multiplying Power Button / Reset Button: Press to cycle through X1, X10, or X100 on the display (default is X1). Rotating the adjustment plate will then increase/decrease the output by 1, 10, or 100 RPM respectively. Press and hold this button for 3 seconds to reset the displayed number.
5.3. Speed Measurement
- Marking the Object: Mark near the center of the object to be measured, or identify existing marks. Unsymmetrical marks are preferred for easier observation.
- Power On: Press the power button to turn on the instrument. The last saved rotate speed will be displayed.
- Unknown Speed Measurement:
- Estimate the approximate speed range of the object.
- Aim the stroboscope's flicker at the target.
- Adjust the multiplying power to a high setting (e.g., X100).
- Rotate the adjustment plate to quickly decrease the rotate speed.
- Once a stable image appears, decrease the multiplying power further if needed, then use the adjustment plate for fine-tuning (increasing or decreasing) until a stable single image appears for the first time.
- The reading on the display is the RPM of the object.
- Known Speed Measurement:
- Adjust the instrument to the corresponding known rotate speed.
- Set the multiplying power to X1 for fine adjustment.
- When a stable single image appears for the first time, the reading on the display is the RPM of the object.
5.4. Dynamic Observation
Follow the same steps as speed measurement. Once a stable single image appears, slightly adjust the rotate speed to make the flickering frequency slightly different from the object's rotate speed. The single image will then appear to rotate slowly. The direction and speed of this apparent rotation can be controlled by fine adjustment. To slow down the apparent movement, narrow the difference between the flickering frequency and the object's rotate speed. Increasing the difference will make it appear faster.
5.5. Judgment of Rotation Direction
Similar to dynamic observation, when a stable single image appears for the first time, slightly adjust the rotate speed to create a slight difference in flickering frequency. The single image will then rotate slowly, and its apparent rotation direction will correspond to the actual rotation direction of the object.
5.6. Speed Measurement Rules (Theory of Stroboscope)
The flash tachometer emits pulsed light at an adjustable frequency and short duration. If an object (e.g., a fan) rotates at 1300 RPM and the stroboscope's flickering frequency is also set to 1300 RPM, the object's blades will appear in the same position with each flicker. Due to persistence of vision, the blades will seem still. This means when the flickering frequency matches the object's rotation frequency, the object appears stationary, and the flickering frequency indicates the object's true rotate speed.
If the object's rotate speed is 1300 RPM and the flickering speed is 1301 RPM (slightly faster), the object's blades will not quite reach the position of the last flicker, causing them to appear to rotate slowly backward. Conversely, if the flickering speed is 1299 RPM (slightly slower), the blades will appear to rotate slowly forward. This phenomenon allows for observation and measurement of high-speed movement.
5.7. Judgment of Actual Rotate Speed
When using pulsed stroboscopic light sources, the stroboscopic images of moving objects can be complex. A single or double image may appear at multiple flickering frequencies. To find the actual rotate speed:
- If the speed range is known, set the flickering frequency within that range.
- If the speed range is unknown, start from the maximum speed and gradually decrease the flickering frequency. Observe until a stable single image appears for the first time. This is the actual speed.
- Be aware that as the flickering frequency continues to decrease, stroboscopic images may still appear but will be darker and have less contrast. The single, stable, and distinct bright image represents the actual speed. If the single image is slightly dark or has small contrast, it is likely not the actual speed.
6. Power Supply and Charging
The instrument is equipped with an internal lithium battery. Charging is performed via the USB interface. A full charge is indicated by a full battery icon (4 grids) on the LCD display. As the instrument is used, the power level will decrease. When the battery indicator shows empty, the power is insufficient, and the instrument should be charged immediately.
To prolong the battery's service life and overall lifetime, the instrument features automatic charging. Avoid overcharging for extended periods. If the instrument will not be used for a long time, it is recommended to disconnect the plug between the battery and the mainboard or remove the battery to prevent degradation.
7. Maintenance and Safety Information
7.1. Maintenance
- Keep the instrument clean and free from dust.
- Store in a dry environment.
- Ensure proper charging practices as described in Section 6.
7.2. Safety Notes
- Do not knock the instrument with heavy objects or apply excessive force.
- Do not place the instrument in moist environments.
- Avoid exposing the instrument to temperatures higher than 55°C.
- Do not place the instrument in environments with dense acid mist or salt mist.
8. Troubleshooting
8.1. Common Issues
- Instrument not turning on: Ensure the battery is charged. If the battery is fully charged and the instrument still does not turn on, contact customer support.
- Inaccurate readings: Verify that the object is properly marked and that the multiplying power is correctly selected for fine adjustment. Ensure a stable single image is achieved for accurate measurement.
- Display issues: If the display is dim or unreadable, ensure the battery is charged. For models with color screens (SW6800, SW6900), ensure sufficient ambient light or check backlight settings if applicable.
8.2. Language Setting (SW6900)
Some SW6900 units may default to a Chinese interface. The provided manual does not detail language switching. If your device displays Chinese characters, as shown in Figure 8.1, and you require an English interface, please contact SWEVY customer support for specific instructions on how to change the language setting.
9. User Tips
- Initial Battery Conditioning: For optimal battery life, fully charge and discharge the stroboscope several times upon first use.
- Language Settings: If your SW6900 model displays a Chinese interface, and you need to switch to English, contact SWEVY customer support as the manual does not provide specific instructions for this.
- Clear Readings: Ensure the object has a distinct mark for easier and more accurate speed measurement.
10. Warranty and Support