1. Introduction

The LAUNCH SmartSafe AC519 is a fully automatic intelligent automobile air conditioning maintenance equipment designed to integrate functions such as disassembly-free cleaning, refrigerant recovery, filling, and vacuuming. It effectively addresses issues like poor air conditioning cooling effect, large compressor load, high noise, and high fuel consumption. This machine supports both R134a and R1234YF refrigerants, offering a comprehensive solution for automotive A/C system servicing.

LAUNCH SmartSafe AC519 machine with icons for Refrigerant Recovery, Charging, Refill, Vacuuming, Cleaning, and Auto Mode.

Figure 1: LAUNCH SmartSafe AC519 A/C Service Station and its primary functions.

Key Features:

  • Equipped with an automobile refrigerant model database, eliminating the need for manual settings.
  • Supports two refrigerants: R134A and R1234YF.
  • Features forward, reverse, and pulse cleaning functions for effective cleaning.
  • Automatic mode can complete operations such as cleaning, recycling, vacuuming, filling refrigeration oil, and refrigerant with one click. Individual functions can also be executed independently.
  • Built-in printer for printing service reports, working hours, and other relevant information.

2. Safety Information

Please read and understand all safety warnings and instructions before operating the LAUNCH SmartSafe AC519. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Always operate the machine in a well-ventilated area.
  • Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling refrigerants.
  • Ensure the automotive A/C system is not running when the machine is connected for service, especially during flushing.
  • Do not start the car's A/C system during the flushing process to avoid damage and risk of accident.
  • Do not press the button switch for new & used oil bottles during the Flushing-Recovery process.
  • Ensure the machine is properly grounded.
  • Keep children and unauthorized personnel away from the equipment during operation.
  • Refer to local regulations for refrigerant handling and disposal.

3. Product Overview

The SmartSafe AC519 is designed with a scientific spatial structure for efficient operation and maintenance. Familiarize yourself with the main components:

Exploded view diagram of the LAUNCH SmartSafe AC519 showing internal components: Printer, Control panel, New and used oil bottles, Pressure gauge, Refrigerant tank, Dry filter, Power supply, Compressor, Vacuum pump, Condenser, Oil and gas separation module, Driver board.

Figure 2: Internal components of the SmartSafe AC519.

Main Components:

  • Control Panel: User interface for selecting functions and monitoring operations.
  • Printer: For printing service reports and operational data.
  • Pressure Gauges: Monitor high-pressure (HP/TP) and low-pressure (LG) readings.
  • Refrigerant Tank: Stores the refrigerant for recovery and refilling.
  • New and Used Oil Bottles: Separate containers for fresh and recovered oil.
  • Vacuum Pump: Creates vacuum in the A/C system to remove moisture and air.
  • Compressor: Facilitates refrigerant recovery and recycling.
  • Dry Filter: Removes moisture and contaminants from the refrigerant.
  • Oil and Gas Separation Module: Separates oil from recovered refrigerant.
  • Power Supply: Connects the unit to an electrical outlet.

4. Specifications

The following table outlines the technical specifications of the LAUNCH SmartSafe AC519:

Specification table for LAUNCH SmartSafe AC519 including Power Supply, Power, Working Temperature, Relative humidity, Vacuum Pump, Tank, HP/TP Gauge, LG Gauge.

Figure 3: Technical Specifications.

Attribute Value
Model Number LAUNCH SmartSafe AC519
Refrigerant Supported R134A / R1234YF
Power Supply AC 220V / 50Hz OR 110V
Power 1000W
Working Temperature 10~50°C Relative
Relative Humidity <85%
Vacuum Pump 100L/Min, 2Pa (approx. 7.3m³/h)
Refrigerant Tank Capacity 12L
New Oil Bottle Capacity 280ml
Used Oil Bottle Capacity 500ml
LCD Display 240*128
Working Pressure max. 20bar
Backlighting LED
HP/TP Gauge Range 1bar~35bar
LG Gauge Range 1bar~20bar
Certification CE, FCC, RoHS
Warranty 12 Months

5. Setup

5.1 First Use Configuration:

  1. Set Language: Select your preferred language (e.g., English, Simplified Chinese, Traditional Chinese) and press ENTER.
  2. Set Refrigerant Type: Select the refrigerant type you will use (R134A or R1234YF).
    WARNING: After you confirm one type, you will not be able to use it for another type. Choose carefully.
  3. Set Units: Select your desired units (kg/g or lbs) and press ENTER.

5.2 Refrigerant Tank Connection:

  1. Supply approximately 4-6 kg of refrigerant into the machine's internal tank to ensure all functions can run normally.
  2. Fix the external refrigerant tank (Recharging tank) securely on the load cell pan.
  3. Connect the Recharging Tank port of the machine to the port of the refrigerant tank using the recharging refrigerant hose.
  4. Open the valve of the external refrigerant tank and place it upside down on the load cell pan (if applicable for your tank type) to allow refrigerant flow.
Diagram showing the connection of the refrigerant tank to the machine's load cell and ports.

Figure 4: Refrigerant tank connection points.

6. Operating Instructions

6.1 Preparations Before Operation:

  1. Check that there is enough refrigerant in the machine's internal tank (recommended 4-6 kg).
  2. Empty the used oil bottle.
  3. Check the automotive A/C system for any leaks. If leaks are present, they must be repaired first to avoid refrigerant loss during flushing.
  4. Verify that the automotive A/C is running normally before connecting the machine. WARNING: When the machine is running, never run the car's A/C system simultaneously!

6.2 Function Overview:

The control panel provides access to various functions. Here's a summary:

Table of functions and their descriptions on the control panel, including Flushing-Recovery, Database, Recovery, Equipment Maintenance, Vacuum, Discharge non-condensable gases, New oil adding, System function, Recharging, Equipment info, Auto. Mode, Help.

Figure 5: Control panel functions and descriptions.

6.3 Detailed Operation for Key Functions:

Detailed instructions for Flushing-Recovery, Recovery/Recycling, and Vacuum functions with corresponding icons and steps.

Figure 6: Step-by-step instructions for core operations.

  1. Flushing-Recovery:
    • This function cleans out refrigerant and oil sludge, exchanges refrigerant, and improves compressor performance.
    • Before flushing, turn on the A/C system and run it for 5-10 minutes. Set it at the lowest temperature and medium wind. Then turn off the automotive A/C.
    • The flushing time should be more than 30 minutes for good performance. The recovery process time is not included in the flushing time.
    • Operations:
      1. Select the Flushing Function (icon: car with arrows, wrench, and fluid) and press the ENTER key.
      2. Set the flushing time.
      3. Press the ENTER key to start.
      4. When finished, the machine will stop automatically.
    • Notice: It's normal for the solenoid valve to make noise during operation. Do not stop it. Used oil will drain automatically.
    • WARNING: Strictly prohibit pressing the Button switch of new & used oil bottles during this process.
  2. Recovery/Recycling:
    • This function recovers refrigerant from the A/C system.
    • Operations:
      1. Select the Recovery Function (icon: car with arrows and fluid) and press the ENTER key.
      2. Press the ENTER key to start.
      3. After recovery, the used oil will drain automatically.
      4. When finished, the machine will stop automatically.
    • Note: After the process ends, you can drain the used oil manually if needed.
  3. Vacuum:
    • This function cleans water vapor out of the A/C system.
    • The vacuuming process should be more than 15 minutes. Generally, 15 minutes is sufficient for A/C systems with only front ventilation, and 20 minutes for systems with front and rear ventilation.
    • Operations:
      1. Select the Vacuum Function (icon: car with vacuum symbol) and press the ENTER key.
      2. Set the vacuum time.
      3. Press the ENTER key to start.
      4. When finished, the machine will stop automatically.
  4. New Oil Adding: Fill new oil into the A/C system.
  5. Recharging: Recharge refrigerant quantitatively into the A/C system.
  6. Auto Mode: This mode automatically performs a sequence of operations including cleaning, recycling, vacuuming, filling refrigeration oil, and refrigerant with a single command.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SmartSafe AC519.

  • Dry Filter Replacement: Periodically check and replace the dry filter as part of equipment maintenance to ensure efficient refrigerant cleaning.
  • Pipeline Cleaning: Perform pipeline cleaning as indicated by the machine or maintenance schedule.
  • Load Cell Calibration: Calibrate the load cell regularly to ensure accurate refrigerant and oil measurements.
  • Oil Bottle Management: Ensure the used oil bottle is emptied regularly and the new oil bottle is refilled as needed.
  • General Cleaning: Keep the exterior of the machine clean and free from dust and debris.
  • Refrigerant Tank Monitoring: Monitor the refrigerant level in the internal tank and replenish as necessary.

8. Troubleshooting

This section provides guidance for common issues. For complex problems, contact technical support.

  • High-Pressure Alarm: If a high-pressure alarm occurs, check for non-condensable gases in the system. Use the 'Discharge non-condensable gases' function if necessary.
  • Machine Not Starting: Ensure the power supply is correctly connected and the voltage matches the machine's requirements (AC 220V or 110V).
  • Inaccurate Measurements: Calibrate the load cell if refrigerant or oil measurements appear inaccurate.
  • Poor Cleaning Effect: Ensure the flushing time is sufficient (over 30 minutes) and the dry filter is not clogged or due for replacement.
  • Solenoid Valve Noise: A certain level of noise from the solenoid valve during operation, especially during Flushing-Recovery, is normal and not indicative of a fault.

9. User Tips

  • Language Selection: The machine supports English, Simplified Chinese, and Traditional Chinese. If you require a different language interface, please consult the manufacturer for potential updates or alternative models.
  • Refrigerant Type Lock: Be absolutely certain of your primary refrigerant type (R134a or R1234YF) during initial setup, as the machine locks to this selection and cannot be easily changed afterward.
  • Regular Checks: Make it a habit to check refrigerant levels and empty the used oil bottle before starting any major operation to prevent interruptions.
  • Utilize Auto Mode: For comprehensive and streamlined service, leverage the 'Auto Mode' function, which automates multiple steps, saving time and ensuring thoroughness.

10. Warranty and Support

The LAUNCH SmartSafe AC519 comes with a 12-month warranty from the date of purchase, covering manufacturing defects. For technical support, service, or warranty claims, please contact your authorized LAUNCH dealer or the manufacturer directly. Ensure you have your product model number and purchase details available when seeking assistance.

© 2024 LAUNCH. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.