1. Introduction and Overview
The Myoslim Body Shaping Machine is a beauty device designed for weight loss, body shaping, muscle building, and fat burning. It utilizes advanced High-Intensity Focused Electromagnetic (HI-EMT) technology to induce powerful muscle contractions, promoting muscle growth and reshaping the internal muscle structure. This process also triggers significant fat breakdown, releasing fatty acids that are metabolized by the body.
Key features include:
- Advanced HI-EMT Technology: Achieves intense muscle contractions with high-energy focused electromagnetic waves to promote muscle growth and reshape deep internal structures.
- Touch-Controlled Display: A user-friendly interface simplifies operation, allowing clear viewing of information and adjustable screen brightness.
- Real-time Monitoring and Guidance: Displays remaining treatment time, utilized channels, treatment methods, and applied treatment types for effective session management.
- Upgradeability: Offers flexible upgrade options to meet evolving therapeutic needs.
- Precise Body Shaping: Enables contouring of body outlines, shaping the waistline, and creating a peach-like buttocks, targeting key aesthetic areas.
- Advanced Muscle Stimulation: Achieves supramaximal contractions of all gluteal muscles through EMS technology, effectively enhancing muscle tone and definition.
- Scientific and Effective: Combines technological innovation with targeted body sculpting for visible results.
This device is intended for adults who are healthy and do not have metal objects in their body.
2. Safety Precautions and Warnings
2.1 General Safety Measures
- The operating environment should be clean and hygienic to prevent contamination.
- Regular cleaning and disinfection of the equipment and accessories are essential.
- Ensure appropriate temperature and humidity for optimal device performance.
- Provide adequate lighting for clear and correct operation.
- Ensure good ventilation to prevent accumulation of harmful gases.
- Have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies.
- Operators should be familiar with safety procedures and emergency handling.
- Keep the device away from electromagnetic fields or other devices that could cause interference.
- All operators must undergo proper training to understand correct usage and safety procedures.
2.2 Precautions Before Use
- Do not use the device when feeling full; wait at least one hour after meals.
- Remove all metal jewelry before using the instrument.
- Before starting operation, touch the probe vertically to the skin, then turn on the main unit and adjust the intensity.
- Start at the lowest intensity level and gradually increase it according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Wait at least one hour after the operation before consuming food or beverages.
2.3 Contraindications
Do not use the device if any of the following conditions apply:
- Wounds on the skin (avoiding affected areas if using).
- Patients with heart disease (e.g., arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during menstrual period.
- Major surgery patients or diabetic patients.
- Presence of any metal in the body.
- People with cerebrovascular disease (e.g., stroke patients).
2.4 Possible Side Effects
These effects may include, but are not limited to:
- Muscle soreness
- Reduction in muscle fat
- Temporary muscle spasms
- Transient joint or muscle tendon pain
- Localized redness or skin flushing
3. Setup: Device Components and Installation
3.1 Device Components
The main unit features a touch-controlled display and two handles. The handles are designed to be drop-resistant and offer user-friendly operation.


3.2 List of Accessories
| Serial | Name | Quantity |
|---|---|---|
| 1 | Host | 1 set |
| 2 | Handle | 2 |
| 3 | 8*80CM, 8*90CM, 8*100CM belts | 3 |
| 4 | Power cable | 1 |
| 5 | Electronic manual | 1 copy |
3.3 Device Installation
- Install the Handle Bracket: Use a screwdriver to install the handle bracket on both sides of the machine.
- Apply Handle Film: Stick the protective film to the working part of the handle.
- Install the Handle: Align the handle with the bracket hole and fasten the clip. Lock the key ring.
- Connect Power: Connect one end of the power cord to the machine and the other end directly into a main socket. Do not connect multiple machines to one socket.
- Press the Back Switch: Move the manual switch on the rear panel to the 'o' position.
- Press the Front Switch: Single-click the front switch to power on. Long press to power off.
4. Basic Device Operation
4.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. Always turn off the machine before replacing the handle. The handle cannot be replaced while the machine is powered on.
4.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the main socket.
- Move the manual switch on the rear panel to the 'o' position.
- Press the button on the front panel to power on.
- When treatment is finished, press and hold the power button to turn off the machine.
4.3 Navigation Controls and Therapy Settings
Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays the following items and functions:
- List: View available treatment patterns.
- Pattern: Select and adjust treatment patterns.
- Records: Access treatment history.
- Channels Selector: Choose between different channels (A and B) for handle operation.
- Setting up Therapy Parameters: Adjust intensity, time, and frequency.
- Return: Go back to the previous screen.
- Settings: Access system settings.
- Start/Pause Therapy: Begin or pause the treatment.
Mode 1 Operation:
The operation interface for Mode 1 allows adjustment of handle operation time, RF energy regulation, and strength adjustment. The frequency range for Mode 1 is 5-60Hz.
Mode 2 Operation:
The operation interface for Mode 2 allows adjustment of handle operation time, RF energy regulation, strength adjustment, and selection of three different periodic frequencies. The frequency range for Mode 2 is 30-100Hz.
Adjust the corresponding intensity/stage frequency/time according to customer needs. Click the start/pause button to begin. If pausing is required, click the start/pause button again. After work is completed, click the return key to exit.
Single Handle Work:
To achieve single handle work, pull the intensity of the unused handle to the lowest value (zero). For example, if intensity 1 (handle A) is at zero, handle B works alone. If intensity 2 (handle B) is at zero, handle A works alone.
4.4 Therapy Preparation and Handle Placement
Before starting therapy, ensure the following:
- Communicate with patients about the procedure.
- Ensure the patient is in good health.
- Ensure the patient is well-hydrated.
- The patient should wear appropriate clothing.
- Avoid eating in large quantities before treatment.
- Be familiar with the treatment process.
- Avoid drinking alcohol before treatment.
Proper handle placement is crucial for effective treatment. The handles can be placed on various body areas:


Operate according to the controller model purchased and follow the manufacturer's official documentation for the best experience. If you have any questions, contact customer support.
5. Maintenance and Repair
5.1 Daily Inspection
Regularly inspect the instrument and its components. Check if the power socket has a reliable connection to the ground. Verify that the power cord is not damaged before use. If any damage is found, stop using the instrument immediately.
5.2 Cleaning
Instrument cleaning should be performed regularly to ensure sanitation and proper functioning. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off.
5.3 Fuse Replacement
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, turn off the power and unplug the power plug before replacing the fuse.
5.4 Cleaning of Accessories in Contact with Patient
Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak these parts directly in alcohol-based detergent; wipe them with pure cotton material.
5.5 Storage and Transportation
Storage: The instrument should be stored in its original packaging box in a well-ventilated room. The packaging box should be cushioned with padding. The ambient temperature should be between -10°C and 40°C, and the relative humidity should not exceed 93%. Do not store in environments with harmful gases, flammable, explosive substances, or corrosive gases.
Transportation: The instrument in its packaging is suitable for road, rail, air, and water transportation. During loading, unloading, and transportation, it should be protected from severe vibrations and impacts, should not be exposed to moisture, and should not be mixed with flammable or corrosive substances. Specific requirements are detailed in the order contract.
6. Technical Parameters
| Parameter | Value |
|---|---|
| Name | myoslim |
| Input Power Supply | AC110V-220V 50/60Hz |
| Output Maximum Power | 0-1500W |
| Frequency | 5-200Hz |
| Screen Size | 15 inches |
| Product Size | 54*47*50cm |
| Net Weight | 22.3kg |
| Electronic | Yes |
| Power Supply Type | Direct Current |
| Material | Copper |
| Certification | CE, RoHS |
| Item Type | Massage & Relaxation |
| Power Source | Electric (Battery) |
| Application | Body, Commercial |
| Target Area | Body, Legs/Arms |
| Feature | Weight Loss, Cellulite Reduction |
| Treatment Area | Body, Arm, Waist, Abdomen, Buttocks, Upper Legs, Hips |
| Plugs Type | AU, UK, EU, US, CN |
6.1 Electromagnetic Compatibility
Radiated Electromagnetic Field Immunity Test:
| Parameter | Value |
|---|---|
| Port | Enclosure |
| Basic Standard | IEC 61000-4-3:2020 |
| Test Level | 30V/m with 80% AM, 1kHz Modulation |
| Standard Require | A |
| Tester | Sam Liu |
| Temperature | 25°C |
| Humidity | 54% |
7. Common Faults and Troubleshooting
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | The power plug is not inserted into the socket Power switch not on Power fuse failure | Check the power Check the power switch Replace the fuse |
| Handle not working | Check the handle for loose connection | Reseat the handle |
8. Warranty and Support
8.1 Warranty Information
- The warranty period for the main instrument is 1 year (excluding man-made damage).
- The warranty period for accessories is 3 months (excluding man-made damage).
- If a product quality problem occurs within the warranty period, free warranty service will be provided.
- After the warranty period, paid repair or replacement services will be offered.
8.2 Free Warranty Exclusions
Free warranty service is not provided for failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
8.3 Support and Contact
If you have a problem, need service, or require other information, please contact the manufacturer:
Manufacturer: Guangzhou Xinwei Electronics Technology Co., Ltd.
Manufacturing Address: Room 01, 10th Floor, No. 23 Boyan 2nd Road, Baiyun District, Guangzhou
For detailed instructions and further information, please refer to the User Manual (PDF).
9. User Tips
- Consistency is Key: For best results in body shaping and muscle building, adhere to a consistent treatment schedule as recommended by the manufacturer or a professional.
- Hydration: Always ensure you are well-hydrated before and after each session to support your body's metabolic processes.
- Proper Placement: Carefully follow the handle placement diagrams to target the desired muscle groups effectively and safely.
- Start Low, Go Slow: When adjusting intensity, always start at the lowest setting and gradually increase it to a comfortable level to avoid discomfort or injury.