1. Introduction
This handheld digital anemometer is a high-precision air velocity measuring instrument designed for HVAC inspection, ventilation testing, environmental monitoring, and industrial airflow diagnostics. It supports wind speed, air temperature, air volume, and humidity measurement (model-dependent). Selected models feature data logging, audible and visual alarms, and USB communication for PC data analysis. Both integrated and split probe designs are available to meet different measurement scenarios.
2. Safety Information & Precautions
WARNING!
- This product contains rotating sensor components. Avoid contact during operation.
- Use only the specified battery types and power supply.
- Do not disassemble or modify the instrument.
- Keep out of reach of children.
- Electronic waste disposal must follow the WEEE Directive and local EU regulations.
- Do not use the instrument in explosive or flammable environments.
- Avoid exposing the sensor to strong impacts or high-speed debris.
- Do not immerse the device in water or use it in heavy condensation.
- Ensure correct battery polarity during installation.
- Remove batteries if the instrument will not be used for an extended period.
- Do not exceed the specified measurement range to prevent sensor damage.
3. Package Contents
Please check the package for the following items:
- Main unit (Anemometer)
- Sensor probe (integrated or split type depending on model)
- USB cable (for USB-supported models: TA642B/C)
- User manual (this document)
4. Setup
4.1. Battery Installation
- Locate the battery compartment on the back of the device.
- Open the battery cover.
- Insert the correct type and number of batteries according to your model, observing polarity:
- TA640A: 2 × 1.5 V AAA batteries
- TA641A / TA641B: 3 × 1.5 V AAA batteries
- TA642A / TA642B / TA642C: 3 × 1.5 V AA batteries
- Close the battery cover securely.
4.2. Power Supply (USB-supported models)
For TA642A, TA642B, and TA642C models, the device can also be powered via a 5V USB Micro interface. Connect the provided USB cable to the device and a suitable USB power source.
4.3. Probe Type
- Integrated Probe: TA640A, TA641A, TA641B, TA642A, TA642B models feature an integrated sensor probe.
- Split Probe: The TA642C model comes with a split probe design, featuring a retractable handle with a 1m telescopic rod and a 1m cable, providing a total extension of 2m for flexible measurements.
5. Operation
5.1. Power On/Off
Press the power button (usually marked with "ⓘ") to turn the instrument on. Press and hold the power button to turn it off.
5.2. Measurement Modes
Select the desired measurement mode (wind speed, air temperature, air volume, or humidity) using the appropriate buttons on the device. Ensure the sensor impeller rotates freely without obstruction. Place the sensor probe in the airflow direction to be measured. For split models, extend the telescopic rod as required.
5.3. Unit Selection
Press the "UNIT" button to cycle through available wind speed units (m/s, km/h, ft/m, mile/h, knots). Temperature units (℃/℉) can also be switched on supported models.
5.4. Data Hold
Press the "HOLD" button to freeze the current reading on the LCD. Press it again to release and resume real-time measurement.
5.5. Maximum, Minimum, and Average Values
Supported models allow viewing of maximum (MAX), minimum (MIN), and average (AVG) values recorded during a measurement session. Use the "MAX/MIN" button to cycle through these displays.
5.6. Alarms (TA641A, TA641B, TA642A, TA642B, TA642C)
For models with alarm functions, upper and lower wind speed thresholds can be set. If the measured value exceeds or falls below these thresholds, a buzzer will sound and a warning light will flash.
5.7. Data Logging & USB Communication (TA642B/C)
TA642B and TA642C models support data logging of up to 1000 records. These models can export recorded data via a USB port to a computer for communication and analysis. Upper computer software compatible with Windows 7, Windows 8, and Windows 10 is used for communication, graph generation, and printing of xlsx data tables.
5.8. Auto Shut-off
The device automatically shuts off after 10 or 15 minutes of inactivity (depending on the model) to conserve battery life. This feature can be manually disabled if continuous operation is required.
6. Storage and Maintenance
- Clean the housing and sensor gently with a soft, dry cloth. Do not use solvents or abrasive cleaners.
- Store the instrument in a dry, well-ventilated place within the specified storage conditions (-10 to 50 ℃, maximum relative humidity 70% for storage).
- Periodically check battery condition and replace when necessary.
- Ensure the impeller remains clean and free of dust for accurate readings.
- For long-term storage, remove the batteries to prevent leakage and damage.
7. Troubleshooting
If you encounter issues with your anemometer, please refer to the following common problems and solutions:
- Device does not power on: Check battery installation and ensure correct polarity. Replace batteries if they are low or depleted. For USB-powered models, ensure the USB cable is securely connected and the power source is active.
- Inaccurate readings: Ensure the sensor impeller is clean and free from obstructions. Verify that the device is placed correctly in the airflow. Check if the selected measurement unit is correct.
- Display issues: If the display is dim or flickering, replace the batteries.
- No data transfer (TA642B/C): Ensure the USB cable is properly connected to both the device and the computer. Verify that the correct driver and software are installed on your PC and are compatible with your operating system (Windows 7/8/10).
- Alarm not triggering: Check the set upper and lower limit thresholds to ensure they are appropriate for your measurement range.
If the problem persists, please contact customer support.
8. Specifications
Detailed specifications for the Handheld Digital Anemometer series:
| Specification | TA640A | TA641A / TA641B | TA642A / TA642B / TA642C |
|---|---|---|---|
| Wind Speed Measurement Range | 0.1-30.0 m/s | 0.06-30.0 m/s | 0.06-45.0 m/s |
| Wind Speed Accuracy | ±(2% + 0.2 m/s) | ±0.2 m/s + ±2% of reading | ±(2% + 0.2 m/s) |
| Wind Speed Resolution | 0.1 m/s | Selectable 0.01 / 0.1 / 1 | |
| Air Temperature Range | 0-45 ℃ | 0-45 ℃ (32.0-113.0 ℉) | |
| Air Temperature Accuracy | ±2 ℃ | ±2 ℃ (±3.6 ℉) | |
| Air Temperature Resolution | — | Selectable 0.1 / 1 | |
| Humidity Measurement Range | — | 0-99% RH (TA641B only) | — |
| Humidity Accuracy | — | ±8% RH (TA641B only) | — |
| Wind Speed Display | 4-digit LCD, maximum display value 9999 | ||
| Sensor Type | Infrared laser beam cutting method with 8-blade low-friction impeller | ||
| Sampling Rate | 2 times/second | ||
| Repeatability | — | ±2% | |
| Data Storage | — | Up to 1000 records (TA642 series) | |
| USB PC Communication | — | — | Supported on TA642B and TA642C |
| Auto Power-Off | 15 minutes (manually switchable) | 10 minutes (manually switchable) | 15 minutes (manual shutdown available) |
| Operating Environment | -10~50 ℃, Max 80% RH, indoor altitude < 2000 m | ||
| Storage Environment | -10~50 ℃, Max 70% RH (remove battery) | ||
| Product Dimensions (L×W×H) | 168×59×29 mm | 152×55×33 mm | TA642A/B: 239×70×35 mm TA642C: 175×70×35 mm (split type) |
| Display Size | 34×31 mm | 37×41 mm | 53×44 mm |
| Weight (excluding battery) | Approx. 120 g | Approx. 135 g | Approx. 210 g |
| Power Supply | 2 × 1.5V AAA (R03/LR03) | 3 × 1.5V AAA (R03/LR03) | 3 × 1.5V AA (LR06) batteries / USB micro port 5V |
9. User Tips
- For accurate wind speed readings: Ensure the anemometer's fan is directly facing the airflow. Any angle can lead to lower-than-actual readings.
- Maximizing battery life: Always remember to manually disable the auto shut-off feature if you need continuous monitoring, otherwise, let it conserve power. Remove batteries for long-term storage.
- Data analysis for TA642B/C: Utilize the PC software to its full potential. Exporting data to xlsx allows for easy integration into reports, and the real-time curve graphs are excellent for visualizing trends over time.
- Checking Max/Min values: The MAX/MIN function is great for identifying peak gusts or lowest airflow rates without constant monitoring.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
You can also refer to the official user manual PDF for additional details: View User Manual (PDF)