1. Introduction

Thank you for purchasing the SUGON 2020D V2026 Soldering Station. This device is a dual-purpose constant-temperature hot air gun designed for precise PCB, SMD, and BGA repair and welding tasks. It features a powerful 700W output, adjustable airflow, and intelligent temperature control to ensure efficient and safe operation. This manual provides essential information for the safe and effective use of your soldering station.

Video: Product demonstration of the SUGON 2020D V2026 Soldering Station in use.

2. Safety Instructions

WARNING: When the power is switched on, the nozzle temperature is in a high-temperature state. Misuse can cause burns or fire. Please strictly observe the following safety guidelines.

  • Always use the equipment according to the instructions provided.
  • Do not touch the metal parts near the nozzle as they can be extremely hot.
  • Do not use the hot air gun near flammable objects or materials.
  • Inform others in the workspace that the hot air gun's nozzle can cause severe burns and potential accidents.
  • Always turn off the power during breaks or after work.
  • When replacing components or devices, turn off the power and allow the nozzle to cool to room temperature before handling.
  • Ensure the product is used with its rated voltage and frequency. Refer to the label on the back of the machine for details.
  • Do not use this product if it is damaged, especially if the power cord is compromised.
  • This product uses a three-wire grounding plug. It must be inserted into a three-hole grounded socket. Do not modify the plug or use an ungrounded three-headed adapter. For extended wires, use a grounded three-wire power cord.
  • Do not alter the air gun without authorization.
  • When replacing parts, always use original factory parts.
  • Do not allow the air gun to get wet. Do not use or disassemble the air gun with wet hands, and do not pull the power cord.
  • When using the air gun, avoid any actions that may injure yourself or damage objects.
  • Children are not aware of the dangers of electrical products. This product should be used and stored in places not easily accessible to children or under adult supervision.

3. Product Components and Overview

The SUGON 2020D V2026 Soldering Station typically includes the following:

  • SUGON 2020D V2026 Main Unit
  • Hot Air Gun Handle
  • Handle Frame/Stand
  • Air Gun Nozzles (5 types: #5 straight, #7 straight, #10 straight, #7 spiral, #10 spiral)
  • User Manual (this document and a PDF version)
SUGON 2020D V2026 Soldering Station with included accessories

Image: SUGON 2020D V2026 Soldering Station with its main unit, hot air gun, and various nozzles.

SUGON 2020D V2026 Soldering Station with hot air gun and five different nozzles

Image: Close-up of the SUGON 2020D V2026 Soldering Station showing the main unit, hot air gun, and the five included nozzles (three straight, two spiral).

4. Specifications

FeatureSpecification
Model NumberSUGON-2020D-2026
Brand NameSUGON
Power700W
Power SupplyAC220V 50HZ/60HZ, AC110V 50HZ/60HZ
Temperature Range100°C - 500°C (212°F - 932°F)
Air Volume Levels1-160 levels
Maximum Air Volume47 L/MIN (MAX)
CertificationCE, FCC
OriginMainland China
Package Dimensions (L x W x H)30cm x 28cm x 23cm
Package Weight3.35 kg
Dimensions of the SUGON 2020D V2026 Soldering Station

Image: Diagram showing the dimensions of the soldering station: Air gun length 23cm, Line length 100cm, Unit dimensions 19cm (width) x 16cm (height) x 10.5cm (depth).

5. Setup Instructions

Note: When connecting or disconnecting the handle, always turn off the power to prevent damage to the control circuit board.

  1. Connect the Handle: Connect the hot air gun handle to the designated socket on the main unit.
  2. Install Air Nozzle: Select the appropriate air nozzle for your task. Place the selected air nozzle onto the air nozzle bracket, align it with the air outlet, and gently press it downwards until it is securely seated.
  3. Position the Station: Place the soldering station on a stable, heat-resistant surface. Position the hot air gun handle on the handle rack.
  4. Connect Power: Connect the power cord to the main unit and then to a grounded power outlet.
  5. Power On: Turn on the main power switch. The display window will show "---", indicating the station is in standby mode.
Labeled diagram of the SUGON 2020D V2026 Soldering Station

Image: Diagram of the soldering station with labels for Storage Key, Temperature Display, Wind Nozzle Bracket, Air Volume Display, Temperature Adjustment Key, Air Volume Regulation, Power Switch, Air Gun, and Dormant Stent (Handle Stand).

Plug-in air nozzle storage rack on the soldering station

Image: Close-up of the plug-in air nozzle storage rack, showing how nozzles are inserted and stored.

6. Operating Instructions

6.1. Temperature Setting and Storage

  • Warming: Press the "▲" button once to increase the set temperature by 1°C. Hold the "▲" button for at least one second to rapidly increase the temperature until the desired setting is reached, then release.
  • Cooling: Press the "▼" button once to decrease the set temperature by 1°C. Hold the "▼" button for at least one second to rapidly decrease the temperature until the desired setting is reached, then release.
  • Storage (Memory Channels): The station has three working channels (CH1, CH2, CH3) to store temperature and air volume settings.
    1. Set your desired temperature and air volume.
    2. Long press the desired channel button (CH1, CH2, or CH3) for more than one second to save the current settings to that channel.
  • Recall (Memory Channels):
    1. Short press the desired channel button (CH1, CH2, or CH3) for less than one second to recall the saved settings for that channel.
Temperature memory storage channels and adjustment on SUGON 2020D V2026

Image: Display showing temperature memory storage channels (CH1, CH2, CH3) and temperature/airflow adjustment buttons. It also shows the °F/°C switch function.

6.2. Air Volume Adjustment

The air volume can be adjusted from 1 to 160 levels using the rotary knob labeled "AIR" and the up/down buttons on the display. This allows for flexible adjustment to meet diverse soldering requirements, from fine components to large soldering areas.

Air volume adjustment on SUGON 2020D V2026

Image: Display showing air volume adjustment from 20 to 160 levels, with the rotary knob for air regulation.

6.3. Temperature Unit Conversion (°C/°F)

While the unit is in use, simultaneously press and hold the "▲" and "▼" temperature adjustment keys to switch between Celsius (°C) and Fahrenheit (°F) display modes. The display will show "C-C" for Celsius or "F-F" for Fahrenheit.

6.4. Buzzer Settings

When the device is powered ON, press and hold the CH1 and CH2 keys simultaneously to turn ON or OFF the buzzer sound. The temperature display position will show "SPH" and the air volume display position will show "ON" (enabled) or "OFF" (disabled).

Buzzer settings on SUGON 2020D V2026

Image: Display showing "SPH" and "ON/OFF" for buzzer settings, activated by pressing CH1 and CH2 simultaneously.

6.5. Automatic Handle Sensing

The handle features an inductive switch. When you pick up the handle, the system automatically enters the working state. When the handle is placed back into the handle rack, the system enters standby mode, and the hot air gun will cool down automatically.

Magnetic induction heat dissipation handle stand

Image: Close-up of the magnetic induction handle stand, illustrating the automatic cooling and sleep state when the handle is placed on it.

6.6. General Usage Guidelines

  • Ensure the air outlet is clear and free of obstructions during operation.
  • Maintain a distance of at least 3mm between the air outlet and the object being worked on.
  • After use, always place the hot air gun handle on the handle rack. The machine will automatically cool down to below 100°C (standby state) before the power switch can be turned off safely.
  • Different air nozzles may result in slightly different temperatures and working effects. Choose the appropriate nozzle for your specific task.

7. Maintenance

7.1. Heating Element Replacement

Caution: Ensure the heating element has cooled to room temperature before attempting replacement.

  1. Loosen the two fixing screws on the handle.
  2. Unscrew and remove handle housing 1, then remove handle housing 2.
  3. Gently remove the fan and the screws holding the wiring board.
  4. Turn the terminal block over and disconnect the connecting wires of the heating element, noting their original positions.
  5. Carefully remove the old heating element and its mica paper from the steel tube, ensuring not to damage the grounding wire on the steel tube.
  6. Wrap the new heating element with mica paper and insert it into the steel tube, ensuring it is properly seated.
  7. Reconnect the heating element wires to their original positions on the terminal block.
  8. Reassemble the handle in the reverse order of disassembly. Ensure the fixed column on the handle shell aligns with the fixed hole in the steel tube.
Handle breakdown diagram for heating element replacement

Image: Exploded view diagram of the hot air gun handle, showing components like handle housing 1, handle housing 2, heater (heating element), and mica paper for replacement guidance.

7.2. Temperature Calibration

Recalibrate the temperature whenever the heating element is replaced. This machine uses digital temperature calibration, allowing for simple and fast adjustment via key input.

  1. Set the machine temperature to 350°C. Allow the temperature to stabilize.
  2. Place the probe of a thermometer 3-5mm away from the air nozzle. Once the thermometer shows a stable reading, note the value.
  3. Simultaneously press and hold "CH1" and "CH3" until "350" flashes on the display, indicating the machine has entered temperature calibration mode.
  4. Use the "▲" or "▼" temperature setting keys to input the noted reading value from the thermometer.
  5. After inputting the value, press "CH2" to exit calibration mode. The current actual temperature will be displayed after a few seconds, completing the calibration.

8. Troubleshooting

This section provides guidance on common issues. For more complex problems, please refer to the full PDF manual or contact customer support.

Display IndicationMeaningPossible Solution
S-ENo heating core or heating core damageCheck the heating element connection. If damaged, replace the heating element (refer to Section 7.1).
SPEBuzzer indicationThis indicates the buzzer is active. If undesired, disable it (refer to Section 6.4).
---Standby modeThe unit is in standby. Pick up the handle to begin operation.

9. User Tips

  • For delicate work, start with lower air volume and temperature settings and gradually increase as needed.
  • Utilize the memory channels (CH1, CH2, CH3) to quickly switch between frequently used temperature and airflow settings for different tasks.
  • Keep your workspace clean and well-ventilated to ensure optimal performance and safety.
  • Regularly inspect the air nozzles for any blockages or wear and replace them if necessary to maintain consistent airflow.

10. Warranty and Support

For detailed warranty information, technical support, or further inquiries, please refer to the complete user manual PDF available at: SUGON 2020D V2026 User Manual (PDF). You may also contact the seller or manufacturer directly for assistance.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.