1. Product Overview
The PORTXVNSA Nano VNA-H4 Plus is a portable handheld vector network analyzer (VNA) designed for precise measurement of reflection and transmission coefficients. This upgraded version offers enhanced performance with an extended measurement frequency range of 50KHz to 2.7GHz and an increased number of scan points to 401. It features an ergonomic design, a 4-inch IPS LCD display with resistive touch functionality, and a large knob for convenient operation. A built-in 5000mAh battery ensures longer service time.
Key Features:
- Ergonomic Design: Comprehensively upgraded appearance for comfortable handling.
- Extended Measurement Range: 50KHz to 2.7GHz with 401 scan points for detailed analysis.
- Data Storage: Supports SD card for easy storage and export of test data.
- Intuitive Interface: Resistive touch screen and large knob operation for enhanced usability.
- Long Battery Life: Integrated 5000mAh battery provides extended operational periods.
- High-Quality Display: 4-inch IPS LCD with wide viewing angle, accurate color reproduction, high contrast, and uniform brightness.


Package Contents:
The standard package includes the following items:
- NanoVNA-H4 PLUS Host x1
- USB Type-C cable x1
- 15cm SMA male to male TG316 RF cable x2
- SMA Male Calibration Kit OPEN x1
- SMA Male Calibration Kit Short Circuit x1
- SMA Male Calibration Kit LOAD x1
- SMA female to female connector x1
- Type-C to Type-C cable x1
- Touch Pen x1
- Pick x1
A variant package also includes a 32GB memory card.


2. Specifications
| Parameter | Value |
|---|---|
| Measurement Bandwidth | Antenna Analyzer |
| Frequency Range | 50KHz to 2.7GHz |
| Dynamic Range | 80dB (50KHz-900MHz), 60dB (900MHz-1.5GHz), 50dB (1.5GHz-2.7GHz) |
| Reflection Coefficient (SWR) | <1.1 |
| Frequency Accuracy | <0.5 ppm |
| Frequency Stability | <2.5 ppm |
| Scan Points | 401 |
| Display | 4-inch IPS LCD, Resistive Touch Screen |
| Battery | Built-in 5000mAh rechargeable battery |
| Product Size | 160 x 92 x 35 mm |
| Battery Included | No (refers to external batteries, internal is built-in) |
3. Setup
3.1 Initial Inspection
Before first use, ensure the product is free from any damage. Verify all components listed in the package contents are present.
3.2 Charging the Device
The Nano VNA-H4 Plus features a built-in 5000mAh rechargeable battery. Connect the device to a power source using the provided USB Type-C cable to charge it before initial use or when the battery is low.
3.3 Connecting to PC (Optional)
The device supports PC control via Nano Saver software. Connect the Nano VNA-H4 Plus to your computer using the provided USB Type-C cable. This allows for saving Touchstone files, sweeping frequency spans, and displaying/analyzing data on a larger screen.

3.4 Calibration Kit Connection
For accurate measurements, proper calibration is essential. Use the provided SMA Male Calibration Kit (OPEN, SHORT, LOAD) and SMA female to female connector as needed for calibration procedures. Connect the RF cables to the CH0 and CH1/S21 ports as required for your measurement setup.

4. Operating Instructions
The Nano VNA-H4 Plus features a resistive touch screen and a large knob for navigation and control. Refer to the "Menu Structure Map" sheet included in the package for detailed menu navigation.
4.1 Basic Operation
- Power On: Press the power button to turn on the device.
- Navigation: Use the large knob to scroll through menu options and the touch screen for direct selection or input.
- Calibration: Perform a calibration using the provided calibration kit before taking measurements to ensure accuracy.
- Measurement Setup: Select the desired measurement type (e.g., SWR, impedance, cable length) and frequency range.
- Connect Device Under Test (DUT): Connect your antenna or RF component to the appropriate port (CH0 or CH1/S21) using the RF cables.
- Start Scan: Initiate the scan to display the measurement results on the 4-inch IPS LCD.
4.2 Measurement Capabilities
The Nano VNA-H4 Plus is a versatile tool for various RF measurements, including:
- Scanning antenna systems and cables.
- SWR (Standing Wave Ratio) and impedance matching.
- Measuring dual-band and triple-band duplexers.
- Port isolation by frequency band.
- Measuring insertion loss of filters.
- Cable length measurement.


4.3 Data Storage and Export
The device supports an SD card (optional 32GB card available) to facilitate the storage of test data. Data can be exported for further analysis on a computer using compatible software like Nano Saver.
4.4 Product Overview Video
5. Maintenance
5.1 Cleaning
Use a soft, dry cloth to clean the device. Avoid using harsh chemicals or abrasive materials that could damage the screen or casing.
5.2 Storage
After use, store the Nano VNA-H4 Plus in a dry and shady place, away from high temperatures, humidity, and direct sunlight. Keep it out of reach of children and pets.
5.3 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period.
6. Troubleshooting
6.1 General Issues
- Device not powering on: Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable.
- Abnormal noise or equipment error: If you experience any unusual sounds or errors during operation, immediately stop using the device. Check all connections and ensure proper installation. If the issue persists, consult the manufacturer.
- Inaccurate measurements: Ensure the device has been properly calibrated before taking measurements. Check all cable connections for tightness and integrity.
7. User Tips
- For HAM radio enthusiasts and RF electronics hobbyists, this device is highly recommended for its performance in shortwave radio and beyond.
- While the device is intuitive, familiarizing yourself with the "Menu Structure Map" can significantly enhance your operational efficiency.
- Consider using the PC control feature with Nano Saver for more advanced data analysis and visualization, especially for complex measurements.
- Always perform a calibration before critical measurements to ensure the highest accuracy.
8. Safety & Warnings
- This product is intended for adult use only.
- Keep out of reach of children and pets to prevent accidental injury or ingestion of small parts.
- Always follow all instructions for proper use. Misuse may cause harm.
- Ensure correct installation of all components before operation.
9. Manufacturer Information
Manufacturer:
Shenzhen Kace Technology Co., Ltd
Address: 401, Building 3, Hengchangrong (Xinghui) Science and Technology Park, No. 52, Huaning Road, Xinshi Community, Dalang Street, Longhua District, Shenzhen, Guangdong Province Code: 518000
Contact: ivandjy@163.com / +86 17673043225
EU Authorized Representative:
MJCM SARL
Address: 78 avenue des Champs Elysees Bureau 326, France
Contact: mjcm190928@gmail.com / +33-767213611
10. Additional Resources
For a detailed user manual in PDF format, please refer to the official documentation available at: NanoVNA-H4 Plus User Manual (PDF).