Product Overview
The SUGON 2020D is a 700W hot air gun soldering station, designed for lead-free rework, phone PCB chip repair, BGA, and SMD soldering. This manual provides essential information for safe and effective operation, setup, and maintenance of your device.

Safety Instructions
⚠ WARNING: When the power is switched on, the nozzle temperature is in a high temperature state. Misuse may cause burns or fire. Please strictly observe the following:
- Avoid misuse of the air gun; use the equipment according to instructions.
- Do not touch metal parts near the nozzle.
- Do not use the air gun near flammable objects.
- Inform others in the workshop that the wind chutes are highly flammable and can cause dangerous accidents. Turn off the power during breaks or after work.
- When replacing a component or device, turn off the power and allow the nozzle to cool to room temperature.
To avoid damage to air guns and keep the working environment safe, the following shall be observed:
- Use the product with its rated voltage and frequency. Refer to the label on the back of the machine.
- Do not use this product if damaged, especially if the power cord is damaged.
- The product uses a three-wire grounding plug, which must be inserted into a three-hole grounding socket. Do not modify the plug or use an ungrounded three-headed adapter. For extended wires, use a grounded three-wire power cord.
- Do not alter the air gun without authorization.
- When replacing parts, use original parts.
- Do not get the air gun wet. Do not use or disassemble the air gun with wet hands.
- Do not pull the power cord.
- When using an air gun, do not make any rash action that may injure the body or damage objects.
- Children do not know the dangers of electrical products, so this product should be used and stored in places that are not easily accessible to children or under adult supervision.
Specifications
| Feature | Specification |
|---|---|
| Model Number | SUGON-2020D-2026VERSION |
| Power | 700W |
| Power Supply | AC220V 50HZ/60HZ, AC110V 50HZ/60HZ |
| Temperature Range | 100°C - 500°C (212°F - 932°F) |
| Air Volume Level | 1-160 levels |
| Maximum Air Volume | 47L/MIN (MAX) |
| Certification | CE, RoHS, WEEE |
| Origin | Mainland China |
For detailed information, please refer to the User Manual (PDF).
Setup Instructions
A. Connecting the Device
⚠ Note: When connecting and disconnecting the handle, be sure to turn off the power to avoid damaging the control circuit board.
- Connect the handle device to the air gun socket.
- Select the appropriate air nozzle. Use large caliber nozzles whenever possible.
- Place the soldering station in a stable position and put the handle on the handle rack.
- Connect the power cord securely.
- Turn on the power switch. The display window will show "---", indicating the soldering station is in standby state.
B. Plug Type Information

C. Air Nozzle Installation and Removal
The machine is equipped with 2 cyclone nozzles and 3 straight nozzles. Different nozzles provide different working effects. Cyclone nozzles are used for disassembling fragile elements, while straight nozzles are used for components requiring quick disassembly.
- Installation: Place the selected air nozzle on the air nozzle bracket, point it at the air outlet, and gently press the air nozzle downward to ensure it is securely compressed before use.
- Removal: When removing the nozzle, move the handle to the holder of the nozzle, slide it into the card slot to the right, and then gently pull it out.
Operating Instructions
A. Temperature Setting and Storage
- Warming: Directly press the "▲" button once to increase the set temperature by 1°C. The temperature parameter display window will show the set temperature. If you hold the "▲" button for at least one second, the temperature will rise rapidly until the desired setting temperature is reached.
- Cooling: Press the "▼" button once to decrease the set temperature by 1°C. The temperature parameter display window will show the set temperature. If you hold the "▼" button for at least one second, the temperature will drop rapidly until the desired setting temperature is reached.
- Storage: After setting the parameter value, select the desired setting channel (CH1, CH2, or CH3). Long press the respective CH button (e.g., "CH1") to save the modified data to that channel.
- Recall: To recall stored memory data, simply press the respective CH button (e.g., "CH1") for less than 1 second.
B. Temperature Unit Conversion (Celsius/Fahrenheit)
While in use, press and hold both the "▲" and "▼" buttons simultaneously to switch between Celsius (°C) and Fahrenheit (°F). The display will show "C-C" for Celsius or "F-F" for Fahrenheit.
C. Buzzer Setting
In the power-on state, press and hold both "CH1" and "CH2" buttons simultaneously to turn off or enable the buzzer sound. The temperature display position will show "SPH" and the air volume display position will show "On" (enabled) or "OFF" (disabled).
Maintenance
A. General Usage Guidelines
- The air outlet and surrounding area of the hot air soldering station may reach extremely high temperatures. Exercise caution to prevent burns.
- The heating handle must always be placed on the handle rack and not on the workbench or any other surface.
- Keep the air outlet clear and free of obstructions.
- After work, place the heating handle on the handle rack. The machine will automatically cool to below 100°C (entering standby mode) before the power switch can be turned off.
- When in use, the distance between the air outlet and the object should be at least 3mm.
- Choose the appropriate nozzle based on work requirements. Different nozzles may result in slightly different temperatures.
B. Heating Element Replacement
⚠ Note: Replacement heating elements should be cooled to room temperature before replacement. Be careful not to damage the grounding wire on the steel tube or the fan's connection line during replacement.
- Loosen the two fixing screws on the handle.
- Unscrew handle housing 1, then remove handle housing 2.
- Gently remove the fan and remove the screws holding the wiring board.
- Turn the terminal block over and disconnect the connecting wires of the heating element from the terminal block, noting their positions.
- Carefully remove the heating element and the mica paper covering it from the steel tube, ensuring not to break the grounding wire on the steel tube.
- Wrap the new heating element with mica paper and insert it into the steel tube.
- Connect the connecting wires of the heating element to their original positions.
- Assemble the handles in the reverse order of disassembly. Ensure the fixed column on the handle shell is in the fixed hole of the steel tube.

Troubleshooting
A. Display Comparison Table (Error Codes)
| Display | Meaning |
|---|---|
| S-E | No heating core or heating core damage |
| SPE | Buzzer indication |
| --- | Standby state |
| C-C | Celsius state |
| F-F | Fahrenheit state |
B. Temperature Calibration
Recalibrate the temperature whenever the heating element is replaced. This machine uses a digital temperature calibration mode, where the correction value is input via keys, making adjustment simple and fast.
- Set the machine temperature to 350°C. Once the temperature is stable, place the thermometer probe 3-5mm away from the air nozzle. When the thermometer shows a stable reading, record the value.
- Additionally, press and hold "CH1" and "CH3" until "350" flashes, indicating the machine has entered temperature calibration mode.
- Press the temperature setting keys ("▲" or "▼") to input the recorded reading value from the thermometer. After input, press "CH2" to exit calibration mode. The current actual temperature will be displayed in a few seconds, completing the calibration.
User Tips
- For delicate components, use cyclone nozzles for better control and to prevent damage.
- When working on larger components or for quick disassembly, straight nozzles are more effective.
- Always ensure proper grounding to prevent electrical hazards and ensure stable operation.
- Regularly check the heating element and air nozzles for wear and tear to maintain optimal performance.
Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Always refer to the official User Manual (PDF) for the most up-to-date and comprehensive details.