PowMr POW-M Series

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: POW-M25-PRO, POW-M35-PRO, POW-M45-PRO

1. Important Safety Instructions

WARNING: Carefully read and adhere to all safety instructions.

  • Before installing and operating the controller, please read this user manual thoroughly and keep it for future reference.
  • The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
  • Anyone lacking the necessary knowledge, experience, or capabilities for the safe installation and operation requirements should not perform installation or operation.
  • Individuals (including children) who may have physical, sensory, or intellectual impairments that could affect the safe installation and operation should not perform installation or operation.

Controller Installation and Operation Safety

  • This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
  • Install the controller in a well-ventilated environment with adequate clearance around it.
  • Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
  • Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • Do not place any objects on top of the controller.

Battery Installation and Charging Safety

  • Install and charge batteries in well-ventilated or exhaust-ventilated environments.
  • Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
  • Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
  • Ensure that the equipment is properly configured for the type of battery connected to it.

2. Product Overview

The PowMr MPPT Solar Charge Controller is a high-efficiency device designed to enhance the performance and intelligent management of photovoltaic systems. It integrates advanced MPPT technology and multiple intelligent control functions, enabling precise tracking of the maximum power point of the solar array even in fluctuating lighting conditions. The tracking efficiency reaches up to 99%, with peak conversion efficiency as high as 98%, effectively improving overall energy utilization.

The controller features a unique rotary knob for intuitive battery type selection and supports an external remote monitoring screen (POW-Meter) for real-time system status, charging strategy settings, and intelligent alarm functions. Its compact and durable housing, combined with natural heat dissipation, ensures stability and environmental adaptability, making it ideal for off-grid power systems or small to medium-sized solar projects.

2.1 Features

  • Rotary Knob Design: Easily select battery type by turning the knob, reducing misoperation and improving setting efficiency.
  • Integrated Charging Presets: Adaptive charging logic suitable for most battery types, including flooded lead-acid, gel sealed lead-acid, and lithium batteries.
  • Flexible Application: Compatible with 12V/24V system voltages.
  • Multi-stage Charging Algorithm: Optimizes each charging cycle for long-term battery maintenance.
  • Maximum Power Point Tracking (MPPT) Technology: Tracks the maximum power point voltage (Vmp) of the array, ensuring maximum power collection throughout the day.
  • Efficient Charging: Achieves up to 99% tracking efficiency and 98% peak conversion efficiency, minimizing power consumption and heat generation.
  • Adaptive Boost Charging: Monitors battery response to determine boost phase duration, ensuring full charge and extending battery life.
  • Durable and Safe: Includes Charging Current Limitation, Photovoltaic Array Short-circuit Protection, Photovoltaic Input Overcurrent Protection, Load Short-circuit Protection, Photovoltaic Reverse Polarity Protection (does not damage controller), Battery Reverse Polarity Protection, and Over-temperature Protection.
  • Silent Operation: Operates silently due to natural convection for heat dissipation, without a fan.
  • Lithium Battery Activation: Compatible with lithium batteries, adjusting charging cycles and activating protected lithium batteries using solar panel energy.
  • Alarm Function: Equipped with an intelligent alarm function for system abnormalities.
  • Remote Control Function: Supports remote monitoring via an optional remote control screen for real-time data and parameter adjustment.

2.2 Product Appearance

PowMr MPPT Solar Charge Controller connected to solar panels and batteries, highlighting safe, fast, and efficient operation with 98% tracking efficiency and 97% peak conversion.

Figure 2.1: PowMr MPPT Solar Charge Controller in a typical setup, emphasizing efficiency.

PowMr MPPT Solar Charge Controller showing compatibility with multiple 12V/24V batteries including AGM, GEL, FLD, LI, and SLA types.

Figure 2.2: Controller working with multiple 12V/24V battery types.

Multiple views of the PowMr MPPT Solar Charge Controller, showing front, side, and bottom views with terminal connections.

Figure 2.3: Various product views of the PowMr MPPT Solar Charge Controller.

PowMr 25A MPPT Solar Controller with dimensions 4.52in x 6.30in x 2.01in and weight 0.5kg. Features include Pure Sine Wave, 3-States Charging Model, and Lithium battery support.

Figure 2.4: PowMr 25A MPPT Solar Controller dimensions and key features.

Controller Components

No.ComponentNo.Component
1Indicator Light7Load Port (+)
2Battery Type Selection Knob8Load Port (-)
3PV Input Port (+)9RS485 Port
4PV Input Port (-)10Heat Sink
5Battery Port (+)11Mounting Holes
6Battery Port (-)

3. Installation Guide

3.1 Unboxing and Inspection

Before unboxing, check if the packaging is damaged. After unboxing, check if any items inside the packaging are damaged or missing. The package should include:

  • Controller x 1
  • User Manual x 1
  • Mounting Screws x 4

3.2 Installation Location

Consider the following factors for a suitable and safe installation location:

  • Install the controller in an area with good natural ventilation/airflow.
  • Avoid direct sunlight.
  • Ensure sufficient space around the controller. The minimum spacing for the top, bottom, and sides of the controller is 75mm.
  • Install the controller on a non-combustible wall and ensure there are no flammable materials nearby. It is normal for the controller to heat up during operation.
  • Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install, place, or operate the controller directly above the battery, on top of the battery, or in a confined space where batteries are stored, as batteries release explosive gases.

3.3 Installation Process

The controller must be installed vertically with the ports facing downwards to prevent dust or liquid from entering. Follow these steps:

  1. Use the provided mounting screws to first secure the upper two screws onto the wall or bracket, and hang the controller temporarily.
  2. Align the lower mounting holes, insert and tighten the remaining screws to ensure the controller is securely fastened without any wobble.
  3. Check if all screws are tightened properly to prevent loosening due to vibrations.
Diagram showing the vertical installation process of the PowMr solar charge controller on a wall, with screws securing it.

Figure 3.1: Controller installation diagram.

4. Wiring Guide

4.1 Wiring Precautions

  • The installation and wiring must be performed by a licensed electrician.
  • Before wiring, install circuit breakers with the correct specifications on the photovoltaic, battery, and load terminals, and ensure that all circuit breakers are in the OFF position.
  • Follow the wiring sequence: Battery > PV Input > Load; Disconnecting sequence: Load > PV Input > Battery.
  • To avoid short circuits and reverse polarity, ensure that the positive (+) cables are connected to the positive (+) terminals of the devices, and the negative (-) cables to the negative (-) terminals.
  • Using cables that are too thin or loose connections can cause the cables or terminals to overheat. Therefore, ensure all cables are securely connected to minimize transition resistance. Use cables of the appropriate size according to the current requirements of the specific circuit.
  • After installation, check if all wiring connections are secure to avoid overheating caused by loose connections.
  • Do not connect an inverter to the load terminal of the controller, as this could cause irreversible damage to the equipment. If an inverter needs to be connected, it should be connected to the battery.

Warning: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow the appropriate inspection and operation procedures.

4.2 Wiring Specifications

The wire gauge is provided as a reference. If the distance between the PV array and the controller, or between the controller and the battery, is relatively long, larger gauge cables must be used to reduce voltage loss in the circuit and ensure system efficiency.

PV Wiring Specifications

The output current of the photovoltaic array is affected by the type of photovoltaic modules, the connection method, and the angle of sunlight. The minimum wire gauge for the photovoltaic array is calculated based on the short-circuit current of the array. The short-circuit current of the array must not exceed the maximum input current of the controller's PV terminal.

ModelPV Max Input CurrentWire GaugeRecommended Circuit Breaker Model
POW-M25-PRO25A10mm²/8AWG32A-2P
POW-M35-PRO35A10mm²/8AWG40A-2P
POW-M45-PRO45A16mm²/6AWG50A-2P

Note: When PV modules are connected in series, the total open-circuit voltage must never exceed the maximum open-circuit voltage of the controller's photovoltaic array.

Battery Wiring Specifications

The battery wiring specifications must be selected according to the rated charging current.

ModelRated Charging CurrentWire GaugeRecommended Circuit Breaker Model
POW-M25-PRO25A10mm²/8AWG32A-2P
POW-M35-PRO35A10mm²/8AWG40A-2P
POW-M45-PRO45A16mm²/6AWG50A-2P

Load Wiring Specifications

The load wiring specifications must be selected according to the rated output current.

ModelRated Output CurrentWire GaugeRecommended Circuit Breaker Model
POW-M25-PRO15A6mm²/10AWG20A-2P
POW-M35-PRO20A6mm²/10AWG25A-2P
POW-M45-PRO25A10mm²/8AWG32A-2P

4.3 Battery Wiring

Use a screwdriver to loosen the fixed screws on the controller's battery port. After connecting the cables to the ports, tighten the screws to ensure a secure connection.

Wiring diagram showing the connection of a battery to the PowMr solar charge controller, including fuses and an optional inverter.

Figure 4.1: Battery wiring diagram.

Note:

  • During installation, please connect a DC fuse with a current rating matching the battery and controller between the battery and controller to prevent damage to the equipment due to short circuits or overcurrent.

4.4 PV Wiring

Use a screwdriver to loosen the fixed screws on the controller's photovoltaic port. After connecting the cables to the ports, tighten the screws to ensure a secure connection.

Wiring diagram showing the connection of a PV array to the PowMr solar charge controller, including a breaker.

Figure 4.2: PV array wiring diagram.

4.5 DC Output Wiring

Use a screwdriver to loosen the fixed screws on the controller's load port. After connecting the cables to the ports, tighten the screws to ensure a secure connection.

Wiring diagram showing the connection of a DC load to the PowMr solar charge controller, including a fuse.

Figure 4.3: DC output wiring diagram.

4.6 RS485 Communication

This controller is equipped with an RS485 communication port, which can be used to connect a remote control screen for real-time monitoring of the system's operating status and parameter settings.

Diagram showing the PowMr solar charge controller connected to a remote control screen via an RS485 port, displaying system states like temperature, battery type, and load current.

Figure 4.4: RS485 communication setup with remote control screen.

Tip:

  • The current version does not support firmware upgrades through the RS485 port.
  • The remote control screen is an optional accessory and can be purchased separately based on your needs.

4.7 Connecting an Inverter (Optional)

If you need to connect an inverter to this controller, please follow the correct connection sequence: first, connect the controller to the battery correctly, and then connect the inverter to the battery's output terminal. Do not connect the inverter directly to the controller's load terminal to avoid causing equipment malfunctions or system issues.

Wiring diagram showing the connection of a PV array, battery, DC load, and an optional inverter to the PowMr solar charge controller. The inverter is connected to the battery, not the controller's load terminal.

Figure 4.5: Inverter connection diagram.

Video 4.1: PowMr MPPT Solar Charge Controller product overview and installation guide.

5. Operation Guide

5.1 Pre-Power-On Check

Ensure that all cable connections are securely fixed. Close the circuit breakers in the order of battery, PV input, and load terminals.

When powering on for the first time, observe the status of the controller's indicator light to ensure there are no abnormalities (a solid green light indicates normal operation). If any abnormality is found, immediately disconnect the power and check the wiring.

Diagram illustrating the pre-power-on check sequence for the PowMr solar charge controller, showing connections for battery, PV, and load.

Figure 5.1: Pre-Power-On Check connections.

5.2 LED Indicator Lights

The status of the indicator light can help you preliminarily judge the type of fault. For detailed fault codes, please refer to the remote control screen and consult the troubleshooting section.

LED IndicatorColorStatusDescription
PVGreenSolid OnIndicates normal PV charging status.
Slow BlinkIndicates high PV voltage.
RedSolid OnIndicates low PV voltage.
Slow Blink1. Temperature exceeds 80°C, PV stops charging, error code E60 display.
2. Charging current is too high, PV stops charging.
/No DisplayIndicates no PV input or insufficient PV voltage.
BATSolid OnIndicates the battery voltage is in the boosting stage.
GreenSlow BlinkIndicates the battery voltage is too high, error code E63 display.
Fast BlinkIndicates the battery charging current is too high, error code E73 display.
YellowSolid OnIndicates the battery voltage is too low.
RedSolid OnIndicates level 1 low-voltage alarm.
Fast BlinkIndicates level 2 low-voltage alarm.
LOADGreenSolid OnIndicates normal output from the controller's load terminal.
Fast BlinkIndicates overload at the controller's load terminal.
RedSlow BlinkIndicates load caused battery undervoltage; the controller's load terminal stops supplying power, and the battery has not yet reached the undervoltage recovery voltage.
/No DisplayIndicates load output has been turned off.

5.3 Knob Introduction

The rotary knob allows for easy selection of the battery type. The remote control screen does not support modifying this setting.

Diagram of the battery type selection knob on the PowMr controller, showing positions for SEL, GEL, FLD, L04, L08, and USE.

Figure 5.2: Battery Type Selection Knob.

Serial No.Battery TypeDescription
1SELSealed Lead Acid Battery
2GELGel Sealed Lead Acid Battery
3FLDFlooded Lead Acid Battery
4L044-Cell Lithium Iron Phosphate Battery
5L088-Cell Lithium Iron Phosphate Battery
6USEUser Defined

Notes on Knob Usage:

  • If SEL, GEL, FLD, L04, or L08 is selected, the controller will automatically detect the system voltage and use default charging parameters.
  • If "USE" is selected for the battery type, charging parameters can be modified through the remote control screen.
  • When the battery type is set to "USE" mode, the system voltage (12V/24V) can be selected via the battery type settings interface on the remote control screen.

5.4 Battery Parameter Settings

Before setting the battery parameters, please turn off the photovoltaic input to ensure that the battery is in a non-charging state.

Charging Parameters (for "USE" mode)

When the battery type is set to "USE" (user-defined), five charging parameters can be modified via the remote control screen: boost charging voltage, float charging voltage, low-voltage recovery voltage, low-voltage cutoff voltage, and MPPT recovery charging voltage. If another battery type is selected, the system will use the default voltage parameters.

Operation Method: Enter the charging parameters, press ▲ or ▼ to switch to the next or previous setting value, press ▲ or ▼ to increase or decrease the value, and finally press ENT to confirm the settings.

Example Display:
Fast CHG: 14.4V
FloatCHG: 13.8V
Rec. Vol: 12.6V
Low Vol: 11.0V
Mppt Vol: 13.2V
MaxChgCur: 45.0A
[ENT] To Save

Charging Voltage Parameters for Each Battery Type

For Lead-Acid Batteries and User-Defined Batteries:

ParametersFLdGELSELUSE
Boost charging voltage14.6V14.2V14.4V9.0~17.0V
Float charging voltage13.8V13.8V13.8V9.0~17.0V
Low-voltage cutoff voltage11.0V11.0V11.0V9.0~17.0V
Low-voltage recovery voltage12.6V12.6V12.6V9.0~17.0V

For Lithium Iron Phosphate Batteries:

ParametersL04L08USE
Boost charging voltage14.5V29.0V9.0~17.0V
Float charging voltage13.8V27.6V9.0~17.0V
Low-voltage cutoff voltage11.2V22.4V9.0~17.0V
Low-voltage recovery voltage12.0V24.0V9.0~17.0V

Important Notes on Battery Parameters:

  • Before modifying parameters, set them according to standard values. Incorrect voltage parameters may lead to reduced battery performance or damage.
  • The charging parameters for lead-acid and user-defined batteries are for a 12V system. For a 24V system, these values should be multiplied by 2.
  • When the battery type is set to "USE," the battery voltage parameters must follow the logic: Boost charging voltage > Float charging voltage > DC low-voltage recovery voltage > DC low-voltage cutoff voltage.
Close-up of the PowMr controller's LCD screen showing battery voltage calibration instructions. It indicates to long press BAT/▲ key to enter settings and use BAT/▲ and DC/▼ keys to adjust values.

Figure 5.3: How to calibrate battery voltage.

5.5 Charging Algorithm

This controller supports an intelligent multi-stage charging algorithm, adapting to different battery types for efficient and reliable charging.

Lead-acid Battery Charging (3 Stages)

For lead-acid batteries, a three-stage charging mode (constant current, constant voltage, float) is used.

  • Fast Charging Stage: Charges the battery with maximum current until it reaches the set boost charging voltage.
  • Boost Charging Stage: Continuously charges at the set boost voltage, gradually reducing current until the battery is fully charged.
  • Float Stage: Reduces charging voltage to the float voltage setting, maintaining a full charge with lower current to prevent overcharging and extend battery lifespan.
Graph illustrating the 3-stage charging algorithm for lead-acid batteries, showing voltage and current profiles for Bulk, Boost, and Float stages.

Figure 5.4: Lead-acid Battery 3-Stage Charging Algorithm.

Lithium Battery Charging (2 Stages)

For lithium batteries, a two-stage charging mode (constant current, constant voltage) is employed.

Graph illustrating the 2-stage charging algorithm for lithium batteries, showing voltage and current profiles for Bulk and Boost stages.

Figure 5.5: Lithium Battery 2-Stage Charging Algorithm.

Tip: The parameters of the charging mode can be flexibly set according to actual needs through the remote control screen. All settings will be automatically saved and retained even if the controller is disconnected from the battery or photovoltaic input.

5.6 Operating Mode Description

You can view the operation mode code on the display page of the remote control screen. Press ▲ or ▼ to switch between the main pages.

Example Display:
Dev. Temp: 26.0°C
State: 7.0 E00
Batt.: SEL S12V
Load Curr: 1.5A
LoadPower: 18.9W
LoadToday: 0.6kWh

CodeDescription
3.0Night mode, not charging
4.0Fast charging mode (MPPT mode)
7.0Boost charging mode
8.0Float charging mode

5.7 Load Control Mode

The load control mode can be set through the remote control screen. The operation steps are as follows:

  1. In the main menu, select the load control mode and click ENT to enter the load control mode page.
  2. Press ▲ or ▼ to switch the load working mode.
  3. If setting the time, press ◀ or ▶ to switch to the previous or next setting value, then press ▲ or ▼ to increase or decrease the value.
  4. Finally, press ENT to confirm the setting.
Diagram showing the flow for setting load control modes (PV+Time, OFF-Mode, Time-Control, PV-Control) on the remote screen.

Figure 5.6: Load Control Mode setting flow.

ModeDescription
PV+TimeLight control and time control mode. The set duration indicates how long the load will remain on after sunset. 24H setting means always-on mode.
OFF-ModeAlways-off mode.
Time-ControlTime control mode. The load is turned on and off according to the set on/off times.
PV-ControlLight control mode. The load output is turned on after sunset and turned off after sunrise.
Image showing three different load work modes: 00H (Load Turn OFF), 24H (Load always Turn ON), and 01H~23H (Time control).

Figure 5.7: Multiple Load Work Modes.

6. Protection Features

6.1 Protection Function

ProtectionDescription
PV input overcurrentThe controller limits the battery charging current to the maximum rated battery current. Therefore, a PV array with overcurrent input will not be able to operate at peak power.
PV array short circuitWhen a short circuit occurs in the PV array, the controller will stop charging. Charging will resume after the short circuit fault is cleared.
PV reverse polarityIf the PV wiring polarity is reversed, the controller will not operate but will not be damaged. The controller will function normally after correct connection.
Battery overvoltageWhen the battery voltage exceeds 15.5/31.0V, the controller will stop charging to protect the battery from overcharging damage. Please note that stopping charging means the charging current will be very low.
Battery over-dischargeWhen the battery voltage drops to the low voltage disconnect setting point, the controller will stop discharging to protect the battery from over-discharge damage.
Over-temperature protectionWhen the controller heatsink temperature exceeds 65°C, the controller will automatically start reducing the charging current. When the temperature exceeds 80°C, the controller will automatically shut down.

6.2 Troubleshooting

Fault codes can be viewed on the display page of the remote control screen. Press ▲ or ▼ to switch between the main pages.

Example Display:
Dev. Temp: 26.0°C
State: 7.0 E00
Batt.: SEL S12V
Load Curr: 1.5A
LoadPower: 18.9W
LoadToday: 0.6kWh

Fault CodeDescriptionSolution
E18PV input voltage too lowIncrease the PV array voltage by changing the series-parallel configuration or adding more solar panels.
E60Over-temperature protectionWhen over-temperature occurs, the fan automatically starts to provide efficient forced cooling.
E63Battery voltage too highAutomatically stops charging; charging resumes after the battery voltage drops to a normal level.
E65Battery voltage too lowAutomatically stops discharging; discharging resumes after the battery voltage rises to a normal level.
E71PV input voltage too highReduce the PV array voltage by changing the series-parallel configuration or decreasing the number of solar panels.
E73Overcharge currentReduce the PV input power by decreasing the number of solar panels.

7. Maintenance

It is recommended to perform the following inspection and maintenance tasks at least twice a year to ensure optimal operation.

  • Ensure the controller is securely installed in a clean and dry environment.
  • Ensure smooth airflow around the controller and clean dust and debris from the heat sink.
  • Inspect all exposed wires to ensure the insulation is not damaged by excessive sunlight, abrasion, dryness, insects, or rodents. Repair or replace wires as necessary.
  • Tighten all terminals and check for loose, broken, or burnt cable connections.
  • Ensure all parts of the system are properly and securely grounded.
  • Ensure there is no corrosion, insulation damage, overheating, or signs of burning/discoloration at all terminals, and tighten the terminal screws.
  • Check for dirt, nesting insects, and corrosion. Clean them promptly if found.

Warning: Risk of Electric Shock! Before performing the above operations, ensure that all power sources are turned off, and then follow the relevant inspection and operation guidelines.

8. Specifications

ParameterPOW-M25-PROPOW-M35-PROPOW-M45-PRO
Solar Input Parameters
Max. PV Open-Circuit Voltage100V
Max. Input Power (12V System)300W420W540W
Max. Input Power (24V System)600W840W1080W
Input Voltage Range (12V System)<60V<80V<100V
Input Voltage Range (24V System)<60V<80V<100V
Battery Charging Parameters
Charging TechnologyMPPT
Charging Algorithm3 Stages
Nominal System Voltage12V/24V
Battery Voltage Range9~30V
Rated Charging Current25A35A45A
Conversion Efficiency≤98%
Max. Power Point Tracking Efficiency>99%
Temperature Compensation-3mV/°C/2V (default)
Self-Consumption44mA/12V; 26mA/24V
DC Output Parameters
Rated DC Output Current15A20A25A
General Parameters
IP ClassIP32
Operating Temperature Range-35°C ~ +45°C
Humidity Range≤95% Non-condensing
Altitude<3000m
Dimensions160x115x51mm195x135x65mm195x135x65mm
Net Weight497g824g954g

9. User Tips

  • To change any settings on the controller, ensure you first disable or disconnect the PV (solar panel) input.
  • Use thick cables with appropriate ampere protection for all connections to ensure safety and efficiency.
  • The controller is noted for its efficiency, often outperforming PWM controllers.
  • The RJ485 communication port is a valuable feature for remote monitoring and control.
  • The controller supports up to 100V panels, making it versatile for various solar setups.
  • For 12V four-cell LiFePO4 batteries, set the battery type to L04 and save the setting.

10. Warranty and Support

Thank you for choosing the PowMr POW-M series solar controller. Please read this manual carefully to maximize the advantages of your controller.

Warranty Terms:

  • Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided it has been used under normal circumstances and authorized by the company's technical personnel.
  • Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.

NOTE: Unauthorized disassembly voids the warranty.

Warranty Exclusions:

Under the following circumstances, PowMr reserves the right not to assume any quality warranty responsibilities:

  • Damage caused by improper transportation.
  • Damage resulting from incorrect storage, installation, or usage.
  • Damage caused by non-professionals or untrained personnel installing and operating the equipment.
  • Damage resulting from non-compliance with the instructions and safety warnings in this document.
  • Damage caused by operation in environments that do not meet the requirements specified in this document.
  • Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
  • Damage resulting from unauthorized disassembly, product alteration, or software code modification.
  • Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
  • Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
  • Products outside the warranty period.

Contact Information:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Add: Henggang Street, Longgang District, Shenzhen, Guangdong, China
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.