1. Introduction
This manual provides essential information for the assembly, installation, operation, and troubleshooting of the PowMr POW-HVM13.2M hybrid solar inverter charger. Please read this manual thoroughly before installation and operation, and keep it for future reference.
The PowMr POW-HVM13.2M is a 13.2kW 48V off-grid hybrid photovoltaic inverter and controller. It integrates a pure sine wave inverter, dual-channel MPPT solar charger, AC/generator charger, and battery energy storage management system into a single multi-functional energy storage power supply. This device can simultaneously connect to solar photovoltaic panels, household AC/diesel generators, and 48V energy storage batteries, intelligently allocating power sources to ensure uninterrupted household power supply. It is compatible with lead-acid batteries and lithium batteries with BMS communication, supports dual-load branch output, mobile WiFi remote monitoring, and battery equalization maintenance. It is suitable for off-grid energy storage in homes, backup power during outages, photovoltaic self-powered cabins, small shops, RV campsites, and other scenarios.
For a more detailed guide, please refer to the official user manual PDF: PowMr POW-HVM13.2M User Manual (PDF)
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview
The PowMr 13.2KW Hybrid Solar Inverter Charger is designed for reliable energy solutions. It features a pure sine wave output, dual MPPT for maximum efficiency, 160A max solar charging, and is compatible with 48V LiFePO4 batteries. It offers WiFi monitoring, low noise operation, a smart LCD display, and multiple protections.



3.1 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- Dual high-power MPPT: Up to 16KW photovoltaic input (8000W + 8000W).
- Deep lithium battery compatibility: Natively supports mainstream energy storage lithium battery BMS communication.
- Dual load intelligent hierarchical output: Retains basic lighting power during power outages.
- Wide-temperature durable body: Operating temperature -10℃~50℃.
- Removable dust filter for easy monthly cleaning.
- Up to 94% inverter peak efficiency, no-load power consumption <80W, energy-saving mode standby power consumption only 15W.
- Multiple customizable power supply priorities: AC priority, solar priority, SBU photovoltaic cell priority, MKS hybrid mode.
3.2 Basic System Architecture
The following illustration shows a basic application for this inverter/charger, including connections to a generator or utility and PV modules. Consult with your system integrator for other possible system architectures. This inverter can power various appliances in home or office environment, including motor-type appliances.

3.3 Product Overview (Physical Components)
The front panel of the inverter includes an LCD display, three indicators, and four function keys for operation and status information.

Key components include:
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- PV1 and PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input
- Anti dust kit
4. Installation
4.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- The unit x 1
- User manual x 1
- Ring terminal x 1
- MC4 terminal head x 2
4.2 Preparation
Before connecting any lines, remove the screws under the machine and the bottom cover plate.
4.3 Mounting the Unit
Consider the following points for installation:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read easily.
- For proper air circulation and heat dissipation, allow a clearance of approximately 20 cm to the side and 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically adhered to the wall.
- Ensure enough space around the machine for heat dissipation and wiring.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M4 or M5 screws.

4.4 Battery Connection
CAUTION:
- For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
- All wiring must be performed by qualified personnel.
- Use appropriate cable for battery connection to reduce risk of injury.
Recommended battery cable size for 8.2KW/10.2KW models: 1 x 2AWG (25 mm²) with a torque value of 2 Nm.
Steps for battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into battery connectors of the inverter and ensure bolts are tightened with a torque of 2 Nm in clockwise direction. Ensure correct polarity. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
4.5 AC Input/Output Connection
CAUTION!!
- Before connecting to AC input power source, install a separate AC breaker between the inverter and AC input power source. This ensures secure disconnection during maintenance and protection from overcurrent. Recommended AC breaker spec: 63A for 8.2KW/10.2KW.
- Do NOT mis-connect input and output connectors. There are two terminal blocks with “IN” and “OUT” markings.
- All wiring must be performed by qualified personnel.
- Use appropriate cable for AC input connection.
Suggested cable requirement for AC wires (8.2KW/10.2KW models): 10 AWG (6 mm²) with a torque value of 1.2 Nm.
Steps for AC input/output connection:
- Before making AC input/output connection, open the DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten screws. Connect PE protective conductor (yellow-green) first. L→LINE (brown or black), N→Neutral (blue).
- Insert AC output wires according to polarities indicated on the terminal block and tighten screws. L→LINE (brown or black), N→Neutral (blue).
- Ensure wires are securely connected.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
4.6 PV Connection
CAUTION:
- Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
- Use appropriate cable for PV module connection.
Suggested cable requirement for PV wires (8.2KW/10.2KW models): 1 x 10AWG (6 mm²) with a torque value of 1.2 Nm.
PV Module Selection Parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of the inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage (90Vdc).
INVERTER MODEL: 8.2KW/10.2KW
- Max. PV Array Open Circuit Voltage: 500Vdc
- PV Array MPPT Voltage Range: 90Vdc~450Vdc
Example: For a 250Wp PV module, recommended configurations are provided in the manual to ensure total input power and panel quantity are within limits.
CAUTION: Exceeding the maximum input voltage can destroy the unit!! Check the system before wire connection.
Steps for PV Module Wire Connection:
- Check the input voltage of PV array modules. Acceptable input voltage of the inverter is 120VDC - 500VDC. Ensure maximum current load of each PV input connector is 10A.
- Disconnect the DC circuit breaker.
- Assemble provided PV connectors with PV modules using the following steps:
- Strip cable 8 mm on both ends, being careful not to nick conductors.
- Insert stripped cable into female/male terminal and crimp.
- Insert assembled cable into female/male connector housing.
- Use a spanner to screw the pressure dome tightly.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) and negative pole (-) to negative (-).
4.7 Final Assembly
After connecting all wirings, replace the bottom cover by screwing two screws.
4.8 Communication Connection
- Wi-Fi cloud communication (option): Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" for network setup and registration. The inverter status will be displayed on your mobile phone APP or computer webpage.
- GPRS cloud communication (option): Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the APP from the APP store and refer to the "GPRS RTU Quick Installation Guideline" for network setup and registration. The inverter status will be displayed on your mobile phone APP or computer webpage.
- Battery communication: Communication between the battery and the inverter is achieved via the battery communication interface, allowing information exchange (Baudrate: 9600).
- Lithium battery and inverter connection: Use power cables and communication cables for lithium batteries and inverters.
Note:
- Ensure correct installation of lithium battery and inverter positive and negative positions.
- The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery.
- Before connecting, ensure both the lithium battery and inverter are turned off. It is recommended to install a circuit breaker for the power cables of the lithium battery and the inverter battery interface to prevent sparks.

Diagram showing the RJ45 connections for lithium battery communication (BMS and RS485 ports) and the inverter connection port.
5. Operation
5.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The front panel features an LCD display, three indicators (Status, Charging, Fault), and four function keys. These provide operating status and input/output power information.
LED Indicators:
- INV/AC (Green): Solid On - Output is powered by utility in Line mode. Flashing - Output is powered by battery or PV in battery mode.
- CHG (Green): Solid On - Battery is fully charged. Flashing - Battery is charging.
- FAULT (Red): Solid On - Fault occurs in the inverter. Flashing - Warning condition occurs in the inverter.
Function Keys:
- ESC: To exit setting mode.
- UP: To go to previous selection.
- DOWN: To go to next selection.
- ENTER: To confirm the selection in setting mode or enter setting mode.
5.3 LCD Display Icons
The LCD displays various icons to indicate input source, configuration, fault information, output information, and battery status.
Input Source Information:
- AC Input Icon: Indicates AC input.
- PV Input Icon: Indicates PV input.
- Numeric Display (KW V Hz A): Indicates input voltage, input frequency, PV voltage, charger current (if PV in charging for 10.2KW models), charger power, battery voltage.
Configuration Program and Fault Information:
- (8.8.8) Icon: Indicates setting programs.
- Warning/Fault Code Icon: Indicates warning and fault codes. Flashing for warnings, solid for faults.
Output Information:
- Numeric Display (KW VA %): Indicates output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.
Load Information:
- OVER LOAD Icon: Indicates overload.
Mode Operation Information:
- Mains Connection Icon: Indicates unit connects to the mains.
- PV Panel Connection Icon: Indicates unit connects to the PV panel.
- AC BYPASS Icon: Indicates load is supplied by utility power.
- Utility Charger Circuit Icon: Indicates the utility charger circuit is working.
- DC/AC Inverter Circuit Icon: Indicates the DC/AC inverter circuit is working.
Mute Operation:
- Mute Icon: Indicates unit alarm is disabled.
5.4 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.
Key settings include:
- Program 00: Exit setting mode (GOE for one-button restore, GOH for one-button restore setting options).
- Program 01: Output source priority (Utility first, Solar first, SBU priority, MKS priority).
- Program 02: Maximum charging current (10A to 160A).
- Program 03: AC input voltage range (Appliances or UPS).
- Program 05: Battery type (AGM, Flooded, User-Defined, LIB-485).
- Program 06: Auto restart when overload occurs.
- Program 07: Auto restart when over temperature occurs.
- Program 09: Output frequency (50Hz/60Hz).
- Program 10: Output voltage (220V/230V/240V).
- Program 11: Maximum utility charging current.
- Program 12: Setting voltage point back to utility source when selecting "SBU priority" or "Solar first".
- Program 13: Setting voltage point back to battery mode when selecting "SBU priority" or "Solar first".
- Program 16: Charger source priority (Solar first, Solar and Utility, Only Solar).
- Program 18: Alarm control (on/off).
- Program 19: Auto return to default display screen.
- Program 20: Backlight control (on/off).
- Program 22: Beeps while primary source is interrupted.
- Program 23: Overload bypass.
- Program 25: Record Fault code.
- Program 26: Bulk charging voltage (C.V voltage).
- Program 27: Floating charging voltage.
- Program 29: Low DC cut-off voltage.
- Program 30: Battery equalization.
- Program 31: Battery equalization voltage.
- Program 33: Battery equalized time.
- Program 34: Battery equalized timeout.
- Program 35: Equalization interval.
- Program 36: Equalization activated immediately.
- Program 37: GRID-tie operation (Off grid or Hybrid).
- Program 38: GRID-tie current.
- Program 39: Led pattern light.
- Program 41: Dual output.
- Program 42: Enter the dual output functional voltage point.
- Program 43: Lithium battery protocol (PYLON or PACE).
- Program 44: Delayed grid access.
- Program 45: Maximum Second Load.
5.5 Display Setting
The LCD display information can be switched by pressing the “UP” or “DOWN” key. Information displayed includes input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, load in Watt, DC discharging current, and main CPU Version.
5.6 Operating Mode Description
The inverter operates in various modes, each with specific display information:
- Standby Mode: Displays input voltage, PV voltage, battery voltage, output voltage, load in Watt, and charging status.
- Line Mode: Displays input voltage, PV voltage, battery voltage, output voltage, load in Watt, and charging status.
- Grid-Tie Operation: Displays input voltage, PV current, battery current, output voltage, load in VA, and charging status. When working in Grid-Tie mode, the grid icon will flash every 3 seconds.
- Battery Mode: Displays input voltage, PV voltage, battery voltage, output voltage, load in Watt, and charging status.
6. Clearance and Maintenance for Anti-Dust Kit
6.1 Overview
Every inverter comes with a factory-installed anti-dust kit. The inverter automatically detects this kit and adjusts its internal thermal sensor to maintain temperature. This kit prevents dust from entering the inverter, increasing product reliability in harsh environments.
6.2 Clearance and Maintenance
The anti-dust kit should be cleaned from dust every one month.
- Step 1: Loosen the screw in a counterclockwise direction on the top of the inverter.
- Step 2: Remove the dustproof case and take out the air filter foam.
- Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
7. Troubleshooting
This section provides common problems, possible causes, and solutions.
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer active for 3 seconds, then off. | Battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. Battery voltage is far too low (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but unit works in battery mode. | Input voltage displayed as 0 on LCD, green LED flashing. | Input protector is tripped. | Check if AC breaker is tripped and AC wiring is connected well. |
| Green LED is flashing. | Insufficient quality of AC power (Shore or Generator). | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS/Appliance). | |
| Green LED is flashing. | Set "Solar First" as priority of output source. | Change output source priority to Utility first. | |
| When unit is turned on, internal relay switches on/off repeatedly. | LCD display and LEDs are flashing. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Fault code 07 | Overload error. Inverter is overload 110% and time is up. | Reduce connected load by switching off some equipment. |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. / Internal temperature of inverter component is over 100°C. | Check whether air flow is blocked or ambient temperature is too high. | |
| Fault code 03 | Battery is over-charged. / Battery voltage is too high. | Return to repair center. / Check if spec and quantity of batteries meet requirements. | |
| Fault code 01 | Fan fault. | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below 190Vac or higher than 260Vac). | 1. Reduce connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if error happens again, return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
Battery Alarm Codes (Lithium Battery Mode):
| Alarm code | Alarm event | Warning condition |
|---|---|---|
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.85V; Lithium battery total voltage <42V (48V lithium battery). |
| 05 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.55V; Total voltage of lithium battery >54V (48V lithium battery). |
| 06 | The battery is low warning | Remaining battery capacity ≤10%. |
Battery Fault Codes (Lithium Battery Mode):
| Fault code | Fault event | Fault condition |
|---|---|---|
| 02 | The battery temperature is too high | Lithium battery charging battery temperature ≥65°C; The discharge temperature of the lithium battery is higher than 70°C. |
| 03 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.65V; Total voltage of lithium battery >54.6V (48V lithium battery). |
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.71V; Lithium battery total voltage <40.4V (48V lithium battery). |
8. Specifications
8.1 Line Mode Specifications
| Feature | Specification |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
| Output power derating | When AC input voltage drops to 170V, the output power will be derated. |
8.2 Inverter Mode Specifications
| Feature | Specification |
|---|---|
| Rated Output Power | 13.2KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Output Frequency | 50Hz |
| Peak Efficiency | 94% |
| Overload Protection | 5s@≥150% load; 10s@101%~150% load |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 48Vdc |
| Cold Start Voltage | 46.0Vdc |
| Low DC Warning Voltage (@ load <50%) | 44.0Vdc |
| Low DC Warning Voltage (@ load ≥50%) | 42.0Vdc |
| Low DC Warning Return Voltage (@ load <50%) | 45.0Vdc |
| Low DC Warning Return Voltage (@ load ≥50%) | 44.0Vdc |
| Low DC Cut-off Voltage (@ load <50%) | 41.0Vdc |
| Low DC Cut-off Voltage (@ load ≥50%) | 40.0Vdc |
| High DC Recovery Voltage | 62Vdc |
| High DC Cut-off Voltage | 61Vdc |
| No Load Power Consumption | < 80W |
| Saving Mode Power Consumption | < 15W |
8.3 Two Load Output Power
| Feature | Specification |
|---|---|
| Full Load | 13200W |
| Maximum Main Load | 13200W |
| Second Load Range | 2640W to 6600W |
| Main Load Cut Off Voltage | 44VDC |
| Main Load Return Voltage | 52VDC |
8.4 Charge Mode Specifications
| Feature | Specification |
|---|---|
| Charging Algorithm | 3-Step |
| AC Charging Current (Max) | 140Amp |
| Bulk Charging Voltage (Flooded Batteries) | 58.4Vdc |
| Bulk Charging Voltage (AGM/Gel Battery) | 56.4Vdc |
| Floating Charging Voltage | 54Vdc |
| Max. PV Array Power | 8000W*2 |
| Nominal PV Voltage | 300Vdc |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc |
| I Max. PV | 22A/22A |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Max Charging current (AC charger plus solar charger) | 160Amp |
8.5 General Specifications
| Feature | Specification |
|---|---|
| Safety Certification | CE |
| Operating Temperature Range | -10°C ~ 50°C |
| Storage Temperature | -15°C ~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimensions (D*W*H) | 580 x 370 x 136 mm |
| Net Weight | 14 kg |
8.6 Approximate Back-up Time Table
| Load (W) | Backup Time @ 48Vdc 100Ah (min) | Backup Time @ 48Vdc 200Ah (min) |
|---|---|---|
| 500 | 613 | 1288 |
| 1000 | 268 | 613 |
| 1500 | 158 | 402 |
| 2000 | 111 | 271 |
| 2500 | 90 | 215 |
| 3200 | 76 | 182 |
| 3500 | 65 | 141 |
| 4000 | 50 | 112 |
| 4500 | 44 | 100 |
| 5000 | 40 | 90 |
| 6200 | 36 | 80 |
| 7200 | 32 | 70 |
| 8200 | 28 | 60 |
| 9200 | 24 | 50 |
| 10200 | 20 | 40 |
Note:
- Backup time depends on the quality of the battery, age of battery, and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.
9. Warranty and Support
The PowMr 13.2KW Hybrid Solar Inverter Charger comes with a 1-year warranty.
For technical support or service, please contact PowMr directly:
- Tel/Fax: +86755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

10. User Tips
- Ensure all connections, especially battery and AC, are made by qualified personnel to prevent damage or injury.
- Regularly clean the anti-dust kit (monthly) to maintain optimal performance and extend the inverter's lifespan.
- Pay close attention to the LCD display and LED indicators for any warnings or fault codes, and refer to the troubleshooting section promptly.
- When setting up the system, carefully consider the PV module selection parameters to match the inverter's voltage and current ranges.