1. About This Manual
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
2. Safety Instructions
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Introduction
This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
3.1 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible to mains voltage or generator power
- Auto restart while AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- WIFI/GPRS (Optional)
- Can connect to lithium battery
3.2 Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:
- Generator or Utility.
- PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

3.3 Product Overview

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- RS-232 communication port




4. Setup (Installation)
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:
- The unit x 1
- User manual x 1
4.2 Preparation
Before connecting all wirings, please take off bottom cover by removing two screws.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

Install the unit by screwing two screws. It's recommended to use M4 or M5 screws.
4.4 Battery Connection
Recommended battery cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 2.0KVA 12V | 1 x 4AWG | 22 | 2 Nm |
| 3.2KVA 24V | 1 x 6AWG | 14 | 2 Nm |
Please follow below steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as below chart.

- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
Installation must be performed with care due to high battery voltage in series.
4.5 AC Input/Output Connection
Suggested cable requirement for AC wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 2.0KVA 12V | 14 AWG | 0.5~0.6Nm |
| 3.2KVA 24V | 12 AWG | 1.2 Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (
) first.
Ground (yellow-green)- L→ LINE (brown or black)
- N→ Neutral (blue)

Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws.
- L→ LINE (brown or black)
- N→ Neutral (blue)

4.6 PV Connection
Recommended PV module cable size:
| Model | Wire Size | Torque value (max) |
|---|---|---|
| 2.0KVA 12V 3.2KVA 24V | 1x16AWG | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 2.0KVA/3.2KVA |
|---|---|
| Max. PV Array Open Circuit Voltage | 400Vdc |
| PV Array MPPT Voltage Range | 30Vdc-400Vdc |
Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table.
| Solar Panel Spec. (reference) 250Wp | SOLAR INPUT (Min in serial: 4 pcs, max. in serial: 12 pcs) | Q'ty of panels | Total input power |
|---|---|---|---|
| Vmp: 30.1Vdc Imp: 8.3A Voc: 37.7Vdc Isc: 8.4A Cells: 60 | 4 pcs in serial | 4 pcs | 1000W |
| 6 pcs in serial | 6 pcs | 1500W | |
| 8 pcs in serial | 8 pcs | 2000W | |
| 10 pcs in serial | 10 pcs | 2500W |
PV Module Wire Connection:
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.

- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

4.7 Final Assembly
After connecting all wirings, please put bottom cover back by screwing four screws.
5. Operating
5.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel, shown in below chart, is on the front panel of the inverter. It includes three indicators, four function keys and a LCD display, indicating the operating status and input/output power information.

LED Indicator:
| LED Indicator | Messages |
|---|---|
| AC / INV (Green) | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG (Green) | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT (Red) | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Display Icons
The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The selectable information is switched as below order: input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, load in Watt, DC discharging current, main CPU Version.
| Icon | Function description |
|---|---|
| Input Source Information | |
| AC | Indicates the AC input. |
| PV | Indicates the PV input |
| INPUTBATT 888 kW VA Hz | Indicate input voltage, input frequency, PV voltage, charger current (if PV in charging for 2.0KVA models), charger power, battery voltage. |
| Configuration Program and Fault Information | |
| 88 | Indicates the setting programs. |
| 8.8 ERROR | Indicates the warning and fault codes. Warning: flashing with warning code.Fault: lighting with fault code. |
| Output Information | |
| OUTPUTBATTLOAD 888 kW VA Hz | Indicate output voltage, output frequency, load percent, load in VA, load in Watt and discharging current. |
| Battery Information | |
| CHARGING | Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode and charging status in line mode. |
| Load Information | |
| OVER LOAD 100% 25% | Indicates overload. Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%. |
| Mode Operation Information | |
| Indicates unit connects to the mains. | |
| Indicates unit connects to the PV panel. | |
| BYPASS | Indicates load is supplied by utility power. |
| Indicates the utility charger circuit is working. | |
| Indicates the DC/AC inverter circuit is working. | |
| Mute Operation | |
| Indicates unit alarm is disabled. | |
5.4 LCD Setting
After pressing and holding ENTER button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit.
Setting Programs:
| Program | Description | Selectable option |
|---|---|---|
| 00 | Exit setting mode | 00 ESC (Escape) |
| 01 | Output source priority: To configure load power source priority |
|
| 02 | Maximum charging current: To configure total charging current for solar and utility chargers. (Max. charging current = utility charging current + solar charging current) |
|
| 03 | AC input voltage range |
|
| 05 | Battery type |
|
| 06 | Auto restart when overload occurs |
|
| 07 | Auto restart when over temperature occurs |
|
| 09 | Output frequency |
|
| 10 | Output voltage |
|
| 11 | Maximum utility charging current Note: If setting value in program 02 is smaller than that in program in 11, the inverter will apply charging current from program 02 for utility charger. |
|
| 12 | Setting voltage point back to utility source when selecting "SBU priority" or "Solar first" in program 01. | Available options in 2.0KVA 12V model:
|
| 13 | Setting voltage point back to battery mode when selecting "SBU priority" or "Solar first" in program 01. | Available options in 2.0KVA 12V model:
|
| 16 | Charger source priority: To configure charger source priority | If this inverter/charger is working in Line, Standby or Fault mode, charger source can be programmed as below:
|
| 18 | Alarm control |
|
| 19 | Auto return to default display screen |
|
| 20 | Backlight control |
|
| 22 | Beeps while primary source is interrupted |
|
| 23 | Overload bypass: When enabled, the unit will transfer to line mode if overload occurs in battery mode. |
|
| 25 | Record Fault code |
|
| 26 | Bulk charging voltage (C.V voltage) | 2.0KVA 12V default setting: 14.1V 3.2KVA 24V default setting: 28.2V If self-defined is selected in program 5, this program can be set up. Setting range is from 12.5V to 15.5V for 2.0KVA 12V model and 25.0V to 31.5V for 3.2KVA 24V model. Increment of each click is 0.1V. |
| 27 | Floating charging voltage | 2.0KVA 12V default setting: 13.5V 3.2KVA 24V default setting: 27.0V If self-defined is selected in program 5, this program can be set up. Setting range is from 12.5V to 15.5V for 2.0KVA 12V model and 25.0V to 31.5V for 3.2KVA 24V model. Increment of each click is 0.1V. |
| 29 | Low DC cut-off voltage | 2.0KVA 12V default setting: 10.0 V 3.2KVA 24V default setting: 20.0 V If self-defined is selected in program 5, this program can be set up. Setting range is from 10.0V to12.0V for 2.0KVA 12V model and 20.0V to 24.0V for 3.2KVA 24V model. Increment of each click is 0.1V. Low DC cut-off voltage will be fixed to setting value no matter what percentage of load is connected. |
| 30 | Battery equalization |
|
| 31 | Battery equalization voltage | 2.0KVA 12V default setting: 14.6V 3.2KVA 24V default setting: 29.2V Setting range is from 13.0V to 16.2V for 2.0KVA 12V model and 25.0V to 31.5V for 3.2KVA 24V model. Increment of each click is 0.1V. |
| 33 | Battery equalized time | 60min (default) Setting range is from 5min to 900min. Increment of each click is 5min. |
| 34 | Battery equalized timeout | 120min (default) Setting range is from 5min to 900 min. Increment of each click is 5 min. |
| 35 | Equalization interval | 30days (default) Setting range is from 0 to 90 days. Increment of each click is 1 day. |
| 36 | Equalization activated immediately |
|
5.5 Operating Mode Description
| Operation mode | Description | LCD display |
|---|---|---|
| Standby mode / Power saving mode | No output is supplied by the unit but it still can charge batteries. | Charging by utility and PV energy. Charging by utility. Charging by PV energy. No charging. |
| Fault mode | PV energy and utility can charge batteries. | Charging by utility and PV energy. Charging by utility. Charging by PV energy. No charging. |
| Line Mode | The unit will provide output power from the mains. It will also charge the battery at line mode. | Charging by utility and PV energy. Charging by utility. If "solar first" is selected as output source priority and solar energy is not sufficient to provide the load, solar energy and the utility will provide the loads and charge the battery at the same time. |
| Battery Mode | The unit will provide output power from battery and PV power. | Power from battery and PV energy. PV energy will supply power to the loads and charge battery at the same time. Power from battery only. |
5.6 Battery Equalization Description
Equalization function is added into charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize battery periodically.
How to Apply Equalization Function
You must enable battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize
In float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.

Equalize charging time and timeout
In Equalize stage, the controller will supply power to charge battery as much as possible until battery voltage raises to battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until setting battery equalized time is arrived.

However, in Equalize stage, when battery equalized time is expired and battery voltage doesn't rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.

6. Maintenance
6.1 Overview (Anti-Dust Kit)
Every inverter is already installed with anti-dust kit from factory. Inverter will automatically detect this kit and activate internal thermal sensor to adjust internal temperature. This kit also keeps dust from your inverter and increases product reliability in harsh environment.
6.2 Clearance and Maintenance (Anti-Dust Kit)
Step 1: Please remove screws as below.

Step 2: Then, dustproof case can be removed and take out air filter foam as shown in below chart.

Step 3: Clean air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the inverter.
7. Troubleshooting
7.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 |
| 02 | Over temperature | 02 |
| 03 | Battery voltage is too high | 03 |
| 04 | Battery voltage is too low | 04 |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 |
| 06 | Output voltage is too high. | 06 |
| 07 | Overload time out | 07 |
| 08 | Bus voltage is too high | 08 |
| 09 | Bus soft start failed | 09 |
| 51 | Over current or surge | 51 |
| 52 | Bus voltage is too low | 52 |
| 53 | Inverter soft start failed | 53 |
| 55 | Over DC voltage in AC output | 55 |
| 57 | Current sensor failed | 57 |
| 58 | Output voltage is too low | 58 |
| 59 | PV voltage is over limitation | 59 |
7.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 OVER LOAD |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
7.3 Troubleshooting Table
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. The battery voltage is too high. | Return to repair center. Check if spec and quantity of batteries are meet requirements. |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
8. Specifications
8.1 Table 1 Line Mode Specifications
| INVERTER MODEL | 2.0KVA-12V |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |

8.2 Table 2 Inverter Mode Specifications
| INVERTER MODEL | 2.0KVA-12V |
|---|---|
| Rated Output Power | 2000VA/1600W |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac ±5% |
| Output Frequency | 50Hz |
| Peak Efficiency | 94% |
| Overload Protection | 5s@ >150% load; 10s@ 100%~150% load |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 12Vdc |
| Cold Start Voltage | 11.5Vdc |
| Low DC Warning Voltage @ load < 50% | 11.0Vdc |
| Low DC Warning Voltage @ load > 50% | 10.5Vdc |
| Low DC Warning Return Voltage @ load < 50% | 11.5Vdc |
| Low DC Warning Return Voltage @ load > 50% | 11.0Vdc |
| Low DC Cut-off Voltage @ load < 50% | 10.2Vdc |
| Low DC Cut-off Voltage @ load > 50% | 9.6Vdc |
| High DC Recovery Voltage | 14.0Vdc |
| High DC Cut-off Voltage | 16.0Vdc |
| No Load Power Consumption | <25W |
8.3 Table 3 Charge Mode Specifications
| INVERTER MODEL | 2.0KVA-12V |
|---|---|
| Utility Charging Mode | |
| Charging Algorithm | 3-Step |
| AC Charging Current (Max) | 60Amp (@Vi/p=230Vac) |
| Bulk Charging Flooded Battery Voltage | 14.6 |
| AGM / Gel Battery | 14.1 |
| Floating Charging Voltage | 13.5Vdc |
| MPPT Solar Charging Mode | |
| Max. PV Array Power | 2000W |
| Nominal PV Voltage | 240Vdc |
| PV Array MPPT Voltage Range | 30~400Vdc |
| Max. PV Array Open Circuit Voltage | 400Vdc |
| Max Charging Current (AC charger plus solar charger) | 80Amp |
8.4 Table 4 General Specifications
| INVERTER MODEL | 2.0KVA-12V |
|---|---|
| Safety Certification | CE |
| Operating Temperature Range | -10°C to 50°C |
| Storage temperature | -15°C~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimension (D*W*H), mm | 357X273X95 |
| Net Weight, kg | 4.6 |
9. Warranty & Support
For technical support, warranty claims, or any inquiries, please contact:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTDTel/Fax: +86 755-28219903
Email: support@powmr.com
Web: www.powmr.com
Add: Henggang Street, Longgang District, Shenzhen, Guangdong, China
All products have a 1-year warranty from our store.
10. User Tips
- Seamless UPS Mode: Users report fast transfer times when grid power drops, preventing reboots of sensitive electronics.
- Flexible Settings: The inverter allows for easy configuration of custom charging profiles, especially useful for LiFePO4 batteries (bulk/float voltages and cut-off limits).
- Stable Power Output: Provides a clean sine wave output, ensuring smooth operation for sensitive motors and compressor-based appliances.
- Clear Monitoring: The LCD screen offers clear real-time monitoring of input/output voltage and load percentages.
- Fan Operation: The cooling fan typically activates around 500 watts of load. At approximately 700 watts, the fan noise becomes noticeable.
- Idle Power Consumption: The standard idle power consumption is around 33W.
11. Frequently Asked Questions (FAQ)
- Q: Does the inverter have Wi-Fi connectivity?
- A: The inverter is "WIFI Monitoring Ready!" allowing real-time performance monitoring. However, the Wi-Fi module is not included in the standard package and must be purchased separately.
12. Product Video Overview
13. Additional Resources
For a detailed user manual in PDF format, please refer to the official document: PowMr 2KW Hybrid Solar Inverter User Manual (PDF)
flashing with warning code.