1. Introduction
The SWEVY Digital Sugar Meter is a professional, high-precision instrument designed for measuring the sugar content (Brix), temperature, and refractive index of various liquids, such as fruit juices and beverages. It features an HD large screen for clear readings, automatic temperature compensation for accurate data, and a user-friendly interface with one-key zeroing and language switching capabilities. This device is suitable for both indoor and outdoor use, offering quick results in just 3 seconds.
Video: Demonstrating the features and usage of the SWEVY Digital Sugar Meter.
2. Product Overview
The SWEVY Digital Sugar Meter comes in several models (SW35S, SW35T, SW53T), each offering specific measurement ranges and features. All models are designed for ease of use and high accuracy.
2.1. Model Variations
- SW35S: Measures sugar content in the range of 0.0~35%. Displays Brix, Temperature, and Refractive Index. Features one-click clear.
- SW35T: Measures sugar content in the range of 0.0~35.0%. Displays Temperature, Sugar Content, and Refractive Index. Features one-key zeroing.
- SW53T: Measures sugar content in the range of 0.0~53.0%. Displays Temperature, Sugar Content, and Refractive Index. Features one-key zeroing.



2.2. Key Features
- Fast Measurement: Results in 3 seconds.
- High Precision: Measurement accuracy of ±0.2%.
- Automatic Temperature Compensation (ATC): Ensures accurate readings between 10-40°C.
- HD Large Screen: Clear display of temperature, sugar content, and refractive index.
- Durable Design: High-precision metal sample cell, easy to clean.
- IP67 Protection: Dustproof and waterproof.
- Auto Shut-off: Conserves battery life.

3. Setup
3.1. Parts Identification
Familiarize yourself with the main components of your SWEVY Digital Sugar Meter:


- Measurement Slot: Where the sample is placed.
- Optical Prism: The core component for refractive index measurement.
- Display Screen (LCD): Shows readings and settings.
- ZERO Button: Used for zero-setting (calibration) and entering settings.
- START / Power/Measure Button: Turns the device on/off and initiates measurement.
3.2. Battery Installation
The instrument is powered by two AAA batteries. To install or replace batteries:
- Locate the battery cover on the back of the device.
- Remove the battery cover.
- Insert two AAA batteries, ensuring correct polarity.
- Replace the battery cover securely.
3.3. Language Switching
The device supports both Chinese and English interfaces:
- Press and hold the ZERO button for 2 seconds to enter the setting interface.
- Use the START button to navigate and select your desired language (EN for English, CH for Chinese).

3.4. Zero-Setting (Calibration)
Before using the refractometer, it is crucial to perform a zero-setting calibration with clean water or pure water to ensure accuracy. If the reading is not 0.0%, please zero-set it.
- Ensure the measuring slot is clean and dry.
- Place clear water (or pure water) into the sample slot. Ensure there is about 1mm between the water surface and the top of the measuring slot, with a volume of approximately 0.3ml.
- Press the START button.
- Check if the displayed value is 0.0%.
- If the value is not 0.0%, press the ZERO button to reset. Repeat until 0.0% is displayed.

4. Operating Instructions
Follow these steps for accurate measurement of sugar content:
- Preparation: Ensure the instrument is clean and has been zero-set as described in Section 3.4.
- Sample Application: Place the test sample (e.g., juice) into the measurement slot. Ensure the volume is at least half of the sample slot, or approximately 0.3ml. Avoid solutions with suspended solids.
- Measurement: Press the START button. The data will be displayed within 3 seconds.
- Reading: Read the Brix percentage, temperature, and refractive index from the HD screen.
- Repeat for Accuracy: For best results, the solution can be aspirated and measured repeatedly several times to ensure accurate data.
- Cleaning: Thoroughly clean the sample cell after each measurement (see Section 5.1).



5. Maintenance
5.1. Cleaning the Sample Cell
Proper cleaning of the metal sample cell is essential for accurate and consistent measurements.
- After each measurement, thoroughly clean the sample cell.
- Drip clean water into the sample slot and wash with a dropper. Repeat this process more than three times.
- If the measuring slot is difficult to clean, you may use ethanol or soapy water.
- Ensure the sample cell is dry before storing or the next measurement.


5.2. Storage
Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Keep it away from corrosive substances.
6. Troubleshooting
Refer to the table below for common issues and their solutions:
| Status Notice | Cause | Solution |
|---|---|---|
| Low battery | Low voltage | Replace batteries. |
| High temp | Temperature in the measuring slot is out of range | Allow sample/device to reach ambient temperature (10-40°C). |
| Low temp | Temperature in the measuring slot is out of range | Allow sample/device to reach ambient temperature (10-40°C). |
| Re zero | Zero-setting step again | Perform zero-setting calibration with clear water. |
| Less solution | Not enough solution in measuring slot | Add more sample to cover the prism. |
| Less water | Not enough clear water in measuring slot | Add more clear water for zero-setting. |
| Out of range | Excessive concentration | Dilute the sample or use a model with a higher measurement range (e.g., SW53T). |
| Fault | Possible damage to components | Contact customer support for assistance. |
6.1. Cautions
- Do not measure solutions containing suspended solids. If present, remove as much as possible with a spoon or gauze.
- Avoid measuring overly hot or cold liquids and hard objects.
- Do not scratch the optical prism.
- Repeated measurements of solutions with suspended solids can lead to measurement uncertainty.
7. Specifications
Below are the general specifications for the SWEVY Digital Sugar Meter series:
| Attribute | Specification |
|---|---|
| Brand Name | SWEVY |
| Model Number | SW35S/SW35T/SW53T |
| Use | Sugar (for fruits, juices, beverages) |
| Measurement Range | 0-55% Brix (model dependent) |
| Brix Min. Div. / Resolution | 0.1% |
| Measurement Accuracy | ±0.2% / ±1℃ |
| Temperature Compensation | 10-40°C |
| Ambient Temperature | 10-40°C |
| Weight | 140g |
| Size | 117*55*29 mm |
| Power Supply | 2 x AAA batteries (not included) |
| Certification | CE, RoHS |
| High-concerned chemical | None |
| Origin | Mainland China |

8. User Tips
- Consistent Zeroing: Always perform a zero-setting calibration with distilled water before each measurement session or if the ambient temperature changes significantly.
- Sample Temperature: For the most accurate results, ensure your sample is at a stable room temperature (within the 10-40°C ATC range) before measurement.
- Avoid Air Bubbles: When placing the sample, ensure there are no air bubbles on the prism surface, as these can affect accuracy.
- Gentle Cleaning: Use a soft cloth or tissue to clean the prism. Avoid abrasive materials that could scratch the surface.
- Battery Life: If the display shows 'Low battery', replace the batteries promptly to avoid interrupted measurements.