1. Introduction
The SARIK DL2-WLTE-TVC is a smart 4G LTE remote controller designed for managing high-power equipment. It features a 30A relay output, allowing control of various devices via SMS, web interface, or a dedicated mobile application. This controller also includes temperature monitoring with alarm functions and timing control capabilities. The DL2-WLTE-T version is a variant that does not include the power failure alarm function.


2. Setup and Installation
2.1 Package Contents
Before installation, please verify that all components are present:
- DL2-WLTE-TVC Smart 4G LTE Controller
- 4G Antenna
- DC12V Power Adapter (if "With Adpt" version)
- Temperature Sensor (if included)
2.2 SIM Card Installation
- Ensure the controller is powered off.
- Locate the Micro SIM card slot on the device.
- Insert a standard 4G LTE SIM card into the slot. Ensure it is correctly oriented.
- The controller requires a local 4G SIM card for operation.

2.3 Antenna Connection
- Connect the provided 4G antenna to the standard SMA interface on the controller.
- Ensure the connection is secure.
2.4 Power Supply Connection
- Connect the DC12V power adapter to the DC power input port on the controller.
- Plug the power adapter into a suitable power outlet.
- The controller will power on automatically.
2.5 Temperature Sensor Connection
- Connect the temperature sensor to the designated sensor port on the controller.
- Ensure the sensor is placed in the area where temperature monitoring is required.
2.6 Relay Wiring
The controller features two 30A relay outputs. Refer to the wiring diagrams below for common applications. Always ensure power is disconnected before wiring.

- COM (Common): Connect to the power source or load common.
- NO (Normally Open): The circuit is open when the relay is off and closes when the relay is activated.
- NC (Normally Closed): The circuit is closed when the relay is off and opens when the relay is activated.
2.7 Physical Installation
The controller supports two main installation methods:
- DIN35mm Rail Installation: Attach the controller to a standard 35mm DIN rail.
- Screw Installation: Use screws to mount the controller to a flat surface. Refer to the diagram for mounting hole dimensions (115mm x 90mm).

3. Operating Instructions
3.1 Control Methods
The DL2-WLTE-TVC controller offers multiple ways to manage your connected equipment:
3.1.1 SMS Control
You can send SMS commands to the controller's SIM card number to control relays and receive status updates. Specific commands will be detailed in the full product documentation (not provided here).

3.1.2 Mobile App Control (WLTE Control)
The "WLTE Control" app provides a convenient and intelligent interface for managing your controller. The app communicates with the controller via 4G internet access.
- Download the "WLTE Control" app from your mobile app store.
- Register and log in to your account.
- Add your device by scanning a QR code or entering device details.
- Use the app interface to switch relays, monitor temperature, set timers, and receive notifications.


3.1.3 Web Control
The controller can also be managed through a web browser on a PC, offering centralized control capabilities.
- Access the web control interface using the provided URL (refer to product documentation for specific address).
- Log in with your credentials.
- Control relays, view status, and configure settings from your web browser.

3.2 Key Functions
3.2.1 30A Relay Output
The controller provides a powerful 30A relay output, capable of directly driving AC motors up to 3KW per channel, with high protection features.

3.2.2 Temperature Control and Linkage
Monitor real-time temperature and configure the controller to trigger relay switches (ON/OFF) when the temperature exceeds or falls below preset limits. Temperature alarm messages can also be pushed to your device.

3.2.3 Timing Control
Set up to 24 groups of timing schedules to automate the ON/OFF state of connected equipment. This allows for scheduled operations, such as turning on a kettle in the morning or a water heater in the evening.

3.2.4 Power Failure Alert (DL2-WLTE-TVC only)
The DL2-WLTE-TVC model includes a power failure alarm function. In case of power loss or restoration, you will receive an SMS, APP notification, or Email alert.

3.2.5 Email and APP Pushing
Receive email notifications when the temperature reaches a preset value. APP notifications ensure you stay informed about the device's status and any critical events.

3.2.6 Short-time Trigger Switch
This function allows for momentary relay activation (1 to 9 seconds settable), ideal for applications like controlling electric gates or garage doors. You can easily open your garage door with a tap on your phone.

4. Maintenance
- Keep the device clean and free from dust.
- Ensure proper ventilation to prevent overheating.
- Regularly check all wiring connections for security.
- Avoid exposing the device to extreme temperatures or moisture.
- Periodically check for firmware updates through the app or web interface for improved performance and features.
5. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device not responding to SMS/App/Web commands | No 4G signal, invalid SIM card, incorrect commands, device not powered on. | Check 4G signal strength, ensure SIM card is active and has credit, verify command syntax, check power supply. |
| Relay not switching | Incorrect wiring, faulty relay, overload. | Review wiring diagrams, ensure load is within 30A limits, contact support if relay is suspected faulty. |
| Temperature readings are inaccurate | Faulty sensor, sensor placed incorrectly. | Ensure sensor is securely connected and placed in an appropriate environment, replace sensor if necessary. |
| Power failure alert not working (DL2-WLTE-TVC) | Feature not enabled, incorrect settings, SIM card issues. | Verify power failure alert settings in the app/web interface, ensure SIM card is functional for SMS/data. |
6. Specifications
| Feature | Detail |
|---|---|
| Model Number | DL2-WLTE-T/TVC |
| Origin | Mainland China |
| DC Power Supply | Standard adapter DC12V 1A |
| Power Consumption | Standby 12V/50mA, Working Max 12V/200mA |
| 4G Frequency (LTE-FDD) | B1/B3/B5/B7/B8/B20 |
| GSM Frequency | 900/1800mhz |
| SIM Interface | Standard Micro SIM card |
| Antenna Interface | Standard SMA interface |
| Temperature Sensor Interface | 1 sensor port |
| Temperature Detection Range | -40℃ to 120℃ |
| Relay Output | 2 channels, 30A/30VDC, 30A/250VAC, 30A/125VAC |
| Output Logic | Normally open and normally closed |
| Shell Size | 115mm x 90mm x 40mm |
| Box Size | 145mm x 127mm x 45mm |
| DL2-WLTE-T Gross Weight | 300g |
| DL2-WLTE-T Net Weight | 190g |
| DL2-WLTE-TVC Gross Weight | 310g |
| DL2-WLTE-TVC Net Weight | 200g |

7. User Tips
- For optimal 4G connectivity, ensure the antenna is placed in an area with good signal reception.
- When using SMS control, save frequently used commands as templates on your phone for quick access.
- Regularly check the "WLTE Control" app for notifications and device status to ensure continuous operation.
- If controlling critical equipment, consider setting up redundant alerts (SMS, App, Email) for power failure and temperature excursions.
8. Warranty and Support
This product comes with a 1-year warranty from the date of purchase. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the manufacturer directly.