1. Product Introduction
The RD RIDEN RD6024 is a digital control DC step-down voltage regulator designed for precision power applications. It features a high-definition color display, numerical keypad control, and supports high current and kilowatt power output. This device is suitable for various industrial and laboratory applications requiring stable and adjustable DC power.
The RD6024 supports firmware upgrades, allowing for future enhancements and new functions. Please note that the product received may have minor differences in terms of page and function due to continuous updates. Always refer to the actual product for the most accurate information.



2. Technical Specifications
The following table details the technical parameters of the RD6024 DC Power Supply:
| Parameter | Value |
|---|---|
| Model | RD6024 / RD6024-W |
| Input Voltage Range | 7-70.00V |
| Output Voltage Range | 0-60.00V |
| Output Current Range | 0-24.00A |
| Output Power Range | 0-1440W |
| Input Voltage Measurement Resolution | 0.01V |
| Output Voltage Setting Measurement Resolution | 0.01V |
| Output Current Setting Measurement Resolution | 0.01A |
| Battery Voltage Measurement Resolution | 0.01V |
| Input Voltage Measurement Accuracy | ±(1%+5 digits) |
| Output Voltage Accuracy (setting to measurement) | ±(0.3%+3 digits) |
| Output Current Accuracy (setting to measurement) | ±(0.5%+5 digits) |
| Battery Voltage Measurement Accuracy | ±(0.5%+3 digits) |
| Automatic Cut Off Current Value (charging) | Set by user (higher than 100mA) |
| Output Ripple Typical | 100mV@12A, 150mV@24A VPP |
| Working Temperature Range | -10℃~40℃ |
| External Sensor Temperature Detection Range | -10℃~100℃ / 0℉~200℉ |
| External Sensor Temperature Detection Accuracy | ±3℃/±6℉ |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A Load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99Wh |
| Capacity and Energy Statistical Error | ±2% |
| Buck Working Mode | (Input voltage ÷ 1.1) - 1 |
| Over Temperature Protection | System temperature > 80℃ |
| Screen Brightness Setting | 0-5 (6 levels in total) |
| Screen | 2.4 inch color HD display |
| Weight (with package) | About 0.72kg |
| Product Dimension | 167*81*69mm |
| Cooling Fan Start Condition | Output current > 8A or System temperature > 45℃ |
| Cooling Fan Shut Down Condition | Output current < 7.9A and System temperature < 40℃ |
| Certification | CE |
| Protection | Short Circuit Protection, Overcurrent Protection, Overvoltage |



3. Setup and Installation
3.1. Installation Instructions
- Install the device in a stable position without strong vibration or impact.
- Use standard threaded installation; tighten evenly. Do not knock the device.
- Ensure the measured medium (if applicable) is non-corrosive and compatible with the device.
- Do not apply long-term over-range pressure to avoid permanent damage.
3.2. Wiring (3-wire system)
- VCC: Positive power supply (5V / 12V / 24V DC)
- GND: Negative power supply / Ground
- OUT: Signal output
3.3. PC Software Control
The power supply can be monitored and set using PC software. This software offers a user-friendly interface and powerful functions. It supports Windows 7 and above operating systems. Before purchasing, it is recommended to download and test the software to ensure compatibility.

3.4. Mobile APP Control (RD6024-W only)
The RD6024-W model supports mobile APP control via WiFi connection (2.4G signal only, 5G not supported). The APP is available for Android 5.0 and above, and iOS 10.0-13.4 (iPhone 6-11). Search for "RDpower" to download the APP. It is recommended to install and test the APP before purchasing to ensure compatibility.

4. Operating Instructions
4.1. Front Panel Components
The front panel of the RD6024 features various buttons, an encoder potentiometer, and a screen for operation and display.
| Label | Function |
|---|---|
| A | Power button |
| B | SHIFT Second function button |
| C | Quick storage button (MEM) |
| D | Current/Over current protection setting (I-SET) |
| E | Voltage/Over voltage protection setting (V-SET) |
| F | Micro USB port |
| G | Power supply output negative terminal / Battery charging negative terminal |
| H | Battery charging positive terminal (Dedicated terminal for battery charging) |
| I | Power supply output positive terminal |
| J | Output switch (ON/OFF) |
| K | Enter/Confirm button |
| L | Encoder potentiometer / Cancel button |
| M | Direction buttons (Up/Down/Left/Right) |
| N | Keypad (0-9) |
| O | Screen |

4.2. Screen Display Indicators
The 2.4-inch HD color screen provides comprehensive information about the power supply's status and settings.
| Label | Description |
|---|---|
| AA | Actual output voltage value |
| AB | Actual output current value |
| AC | Output power |
| AD | Current data group (M0-M9) |
| AE | Constant voltage (CV) / Constant current (CC) status |
| AF | Protection status indication (e.g., OVP, OCP) |
| AG | Battery charging indication |
| AH | Battery related information display area (Ah, Wh) |
| AI | Over current protection (OCP) value |
| AJ | Over voltage protection (OVP) value |
| AK | Output current preset value (I-SET) |
| AL | Output voltage preset value (V-SET) |
| AM | Input voltage |
| AN | Communication interface status |
| AO | Button lock status |
| AP | Button tune (sound) status |
| AQ | Date and time |

4.3. Display Styles
The system defaults to the Classic Style. You can switch between Classic, Detailed, and Curve styles by pressing the encoder potentiometer (L) or navigating through the settings interface.

4.4. New Settings Interface
The device features an optimized settings interface with a straight waterfall design, level optimization, and function classification. You can enter the system settings interface and use the direction buttons (M) to navigate pages. Supported languages include Chinese, English, German, and Russian, with more languages being continuously updated.
The display color supports over 15 colors and can be freely matched. Custom color settings must be enabled to take effect.

4.5. Output Power Limit
When setting the output voltage and current, the device will automatically adjust to ensure that the power does not exceed the set output power. The output power setting range is 0-1480W. For voltage full-scale output, it is recommended to use a suitable power supply.

5. Maintenance
5.1. Fuse Replacement
The RD6024/RD6024-W comes with a backup fuse in the box. If the operating fuse burns out due to incorrect operation, you can temporarily use the backup fuse by inserting it into the socket next to the burned one. Note that this temporary fuse supports only up to 10A. For full output capability, it is recommended to remove the damaged fuse and solder a new, appropriate fuse in the same position.
5.2. Cooling Fan Operation
The intelligent cooling fan operates based on output current and system temperature:
- Start Condition: Output current > 8A or System temperature > 45℃
- Shut Down Condition: Output current < 7.9A and System temperature < 40℃
5.3. General Care
- Keep the device clean and free from dust.
- Avoid exposing the device to extreme temperatures or humidity.
- Do not disassemble or modify the product yourself, as this will void the warranty.
6. Troubleshooting
6.1. Safety Notes
- This product is NOT explosion-proof. Do not use in flammable or explosive environments.
- Disconnect power before wiring. Reverse wiring may damage the module.
- Keep away from strong electromagnetic interference sources.
- Please follow industrial safety standards during installation and use.
6.2. Common Issues and Solutions
- PC Software/APP Connectivity Issues: Due to potential incompatibilities with some computers or mobile phones, the WiFi connection for PC software is a test function and not fully supported. If you experience issues, try connecting via USB micro cable (for RD6024-W) or ensure your operating system meets the minimum requirements (Win 7+ for PC, Android 5.0+ for APP).
- Product Appearance Variations: Minor differences in internal material details or slight traces on the panel (due to injection molding) are normal and do not affect functionality.
- Inductive Load Usage: When connecting an inductive load (such as a motor), the maximum working voltage and current should not exceed 1/3 of the full range to prevent damage.
7. User Tips
- Always download and test the PC software or mobile APP before purchasing if these features are critical for your use case, as compatibility issues may arise.
- Keep the online instruction manual link handy, as the product is continuously updated, and the latest information will be available there: RD6024 Instruction Download Link.
- If you need to replace a fuse, consider soldering a new one for optimal performance, as the backup fuse is primarily for temporary use at reduced current.
- For high-current applications, ensure you use appropriate output cables (e.g., 2.5mm² or above) with big current banana plugs or U-shaped plugs.
8. Frequently Asked Questions (FAQ)
- Q: What is the difference between RD6024 and RD6024-W?
- A: The RD6024-W model includes a WiFi board, allowing it to connect to the mobile APP and PC software (via USB micro cable). The standard RD6024 does not have a WiFi board and only supports PC software connection via USB micro cable, without APP support. Note that WiFi for PC software is not currently supported.
- Q: Why might the product I receive be slightly different from the pictures?
- A: We continuously update the product hardware and software to improve the device. Therefore, internal material details may vary slightly, but this does not affect the core functions or usability.
- Q: Why does the instruction manual not come with the product?
- A: Due to ongoing product updates and the addition of new functions through firmware and hardware revisions, the most current instruction manual is available online. This ensures you always have access to the latest information.
- Q: Can I use the RD6024 to power an inductive load?
- A: Yes, but if you connect an inductive load (such as a motor), the maximum working voltage and current should not exceed 1/3 of the full range to prevent potential damage to the device.
- Q: There is a backup fuse in the box. Should I install it?
- A: The fuse in the box is a BACKUP fuse. If the primary fuse burns out due to incorrect operation, you can insert the backup fuse into the socket next to the burned one for temporary use. This backup fuse supports only 10A. For full output, it is best to remove the damaged fuse and solder a new, appropriate fuse in its original position.
- Q: I see some traces on the panel. Does this mean it's damaged?
- A: Affected by the injection molding process, slight traces may be present around the button holes on the shell. These are typically hard to notice during normal use and are not indicative of damage. The shell is not a craft item, so minor cosmetic imperfections are normal.
9. Warranty and Support
9.1. Warranty
- Warranty Period: 12 months from the date of purchase.
- Coverage: Free after-sales service for non-human quality defects.
9.2. Technical Support
Professional technical support is available for wiring and application questions.
For any questions or support, please contact our customer service:
- WhatsApp: +86 15232153826
- Email: kaigui8882@163.com
- YouTube Channel: RD tech YouTube Channel
You can also find the latest instructions and software downloads at: RD6024 Instruction Download Link.