1. Introduction
This manual provides essential information for the safe and efficient operation of your PowMr 12KW Hybrid Solar Inverter. This inverter is designed to integrate solar power, utility power, and battery power to provide a reliable and flexible energy solution for both on-grid and off-grid applications. It features dual MPPT solar charge controllers, supports three-phase pure sine wave output, and offers various charging and output modes to optimize energy usage.
Please read this manual thoroughly before installation and operation, and keep it for future reference.
2. Key Features
- Output Type: Three-phase pure sine wave output (350~415V).
- Voltage Adjustment: Supports phase voltage adjustment in the range of 200, 208, 220, 230, 240Vac.
- Energy Management: Time period charging and discharging setting function to optimize peak and valley tariffs.
- Solar Input: Two independent PV inputs with dual MPPT tracking for maximum power charging/carrying capacity.
- MPPT Efficiency: Dual MPPT, efficiency up to 99.9%, single maximum current of 22A, compatible with high-power modules.
- Energy Saving: Energy-saving mode function to reduce no-load energy losses.
- Output Modes: Two output modes: utility bypass and inverter output, with uninterrupted power supply (UPS) function.
- Battery Compatibility: Supports lead-acid (AGM, GEL, FLD, SLD, USER) and lithium-ion (LI) battery connections.
- Li-ion Battery Activation: Dual activation function for dormant li-ion batteries; activated by either mains or photovoltaic power supply.
- Communication: Supports CAN, USB, and RS485 communication.
- Charging Modes: Four selectable charging modes: solar only, mains priority, solar priority, and mixed mains and PV charging.
- Display: LCD large screen with dynamic flow diagram for easy system data and operation status monitoring.
- Comprehensive Protection: 360° protection including short-circuit, over-current, over-voltage, under-voltage, over-load, backfill, over-temperature, and over-charge protection.
3. Setup and Installation
3.1 Unpacking and Inspection
Upon receiving the inverter, carefully unpack it and inspect for any damage. Ensure all components are present. If any damage or missing parts are found, contact your supplier immediately.
3.2 Mounting the Inverter
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure adequate clearance around the unit for proper air circulation. The inverter is designed for indoor use only (IP20 protection degree).
3.3 Connection Overview
The inverter features various connection ports on its bottom panel. Refer to the image below for a visual guide to the connection points.

3.4 Wiring Diagrams
Proper wiring is crucial for safe and efficient operation. All wiring should be performed by a qualified electrician in accordance with local electrical codes.
3.4.1 Three-Phase AC Output Wiring
The inverter provides a three-phase output. The diagram below illustrates the AC output connections and voltage relationships.

3.4.2 Parallel Connection Schematic
Multiple inverters can be connected in parallel to increase system capacity. The following diagram shows a schematic for parallel connection of up to six inverters.

3.5 Battery Connection
The inverter is compatible with 48V lead-acid and lithium batteries. It can also operate without a battery (batteryless mode). The battery charging current setting range is 0-260A.

For lithium-ion batteries, the inverter features a dual activation function: either mains power or photovoltaic power supply can trigger the activation of a dormant li-ion battery.
4. Operating Modes
The PowMr Hybrid Solar Inverter offers flexible charging and output modes to suit various energy requirements.
4.1 Charging Modes
There are four selectable charging modes:
- Solar First: Prioritizes solar power for charging batteries.
- Utility First: Prioritizes utility (grid) power for charging batteries.
- Solar and Utility: Uses both solar and utility power to charge batteries.
- Only Solar: Charges batteries exclusively from solar power.
4.2 Load Output Working Modes
The inverter supports three load output working modes:
- Utility First: Prioritizes utility power to supply the load.
- Solar First: Prioritizes solar power to supply the load.
- SBU First (Solar-Battery-Utility First): Prioritizes solar, then battery, then utility power to supply the load.

4.3 Energy-Saving Mode Function
The inverter includes a time-slot charging and discharging setting function, allowing users to take advantage of peak and valley tariffs to save electricity costs. Excess solar energy generated during the day can be stored in the battery and discharged to power home appliances during evening peak consumption times. This feature also enables the inverter to function as a UPS power supply with zero battery discharge time.

4.4 LCD Display
The inverter features an LCD large screen with a dynamic flow diagram design, making it easy to understand system data and operational status at a glance.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your PowMr Hybrid Solar Inverter.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.
- Connections: Periodically check all electrical connections (AC input, AC output, battery, PV) to ensure they are tight and free from corrosion.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure optimal performance and access to new features.
- Battery Health: If using batteries, monitor their health and charge status as recommended by the battery manufacturer.
6. Troubleshooting
This section provides guidance for common issues. For complex problems, contact qualified service personnel.
- No Power Output: Check AC input, battery connection, and PV input. Verify that the inverter is turned on and not in a fault state.
- Low Power Output: Inspect PV array for shading or damage. Check battery charge level. Ensure correct operating mode is selected.
- Error Codes on LCD: Refer to the inverter's specific error code list (usually found in the full product manual or on the manufacturer's support page) to diagnose the issue.
- Battery Not Charging: Check PV input voltage and current. Verify battery connections and settings. Ensure the selected charging mode is appropriate.
- Overload Protection Triggered: Reduce the load connected to the inverter. The inverter will typically resume output after a short delay once the overload is removed.
- Over-Temperature Protection: Ensure adequate ventilation around the inverter. Clear any obstructions from air vents.
The inverter is equipped with 360° protection features, including short-circuit, over-current, over-voltage, under-voltage, over-load, backfill, over-temperature, and over-charge protection, which will automatically activate to safeguard the system.

7. Specifications
The following table details the specifications for the PowMr POW-SunSmart series hybrid solar inverters.

| Feature | POW-SunSmart 8KPL3 | POW-SunSmart 10KPL3 | POW-SunSmart 12KPL3 |
|---|---|---|---|
| Rated Output Power | 8,000W | 10,000W | 12,000W |
| Max. Peak Power | 16,000W | 20,000W | 24,000W |
| Rated Output Voltage | 230/400Vac (three-phase) | ||
| Rated Frequency | 50Hz/60Hz | ||
| Output Waveform | Pure Sine Wave | ||
| Switching Time | 10ms (typical) | ||
| Number of Parallel Units | 6 | ||
| Overload Protection | After triggering overload, inverter resumes output after 3 minutes, 5 consecutive overloads will shut down output until restart. (102%<load<110% ±10%: error, shut down after 5 min; 110%<load<125% ±10%: error, shut down after 10s; >125% load ±10%: error, shut down after 5s) | ||
| Battery | |||
| Battery Types | Li-ion / Lead-Acid / User Defined | ||
| Rated Battery Voltage | 48Vdc | ||
| Voltage Range | 40-60Vdc | ||
| Max. PV Charging Current | 180A | 220A | 260A |
| Max. Utility / Generator Charging Current | 100A | 120A | 120A |
| Max. Hybrid Charging Current | 180A | 220A | 260A |
| PV Input | |||
| No. of MPPT | 2 | ||
| Max. Input Power | 6000W/6000W | 7500W/7500W | 9000W/9000W |
| Max. Input Current | 22A/22A | ||
| Max. Open-circuit Voltage | 800Vdc/800Vdc | ||
| MPPT Operating Voltage Range | 200-650Vdc/200-650Vdc | ||
| Utility / Generator Input | |||
| Input Voltage Range | Phase voltage 170-280V, Line voltage 305-485V | ||
| Input Frequency Range | 50Hz / 60Hz | ||
| Bypass Overload Current | 23.2A | 29A | 35A |
| Efficiency | |||
| MPPT Tracking Efficiency | 99.9% | ||
| Max. Battery Inverter Efficiency | ≥92% | ||
| European Efficiency | 97.2% | 97.5% | 97.5% |
| General | |||
| Dimensions (L*W*H) | 620*445*130mm (2.03*1.46*0.43ft) | ||
| Weight | 27kg (59.52lb) | ||
| Protection Degree | IP20, indoor only | ||
| Ambient Temp | -10~55℃, >45℃ derated | ||
| Noise | <60dB | ||
| Cooling Method | Air Cooling | ||
| Communication | |||
| Internal Interface | RS485 / CAN / USB / Dry contact | ||
| External Module (optional) | Wi-Fi / GPRS | ||
| Certification | |||
| Safety | IEC62109-1, IEC62109-2 | ||
| EMC | EN61000-6-1, EN61000-6-3, FCC 15 class B | ||
| RoHS | Yes | ||
8. User Tips
- Professional Installation: Due to the high voltage and complex wiring involved, it is highly recommended to have the inverter installed by a certified electrician to ensure safety and compliance with local regulations.
- Monitor Performance: Regularly check the LCD display for system status and any alerts. Consider using the optional Wi-Fi/GPRS module for remote monitoring.
- Battery Sizing: Ensure your battery bank is appropriately sized for your energy consumption and solar generation to maximize efficiency and battery lifespan.
- Ventilation: Always ensure the inverter has adequate airflow to prevent overheating, especially in warmer climates.
- Consult Full Manual: For detailed wiring instructions, advanced settings, and specific error code explanations, always refer to the comprehensive product manual provided by PowMr.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact PowMr customer service or your authorized dealer. Ensure you have your product model number and purchase details available when contacting support.