Introduction
This manual provides detailed instructions for the proper use and maintenance of your SWEVY SW55S/SW93S Digital Brix Refractometer. This high-precision instrument is designed for accurate measurement of sugar content (Brix), temperature, and refractive index in various solutions, including juices, milk tea, and other beverages. Its automatic temperature compensation and user-friendly interface ensure reliable results.

Key Features
- High Precision: 0.1% Brix resolution for accurate readings.
- Wide Measurement Range: Available in 0-55% Brix (SW55S) and 0-93% Brix (SW93S) models.
- Automatic Temperature Compensation (ATC): Ensures accurate data by reducing errors caused by temperature differences (10-40°C).
- Quick Results: Provides measurements in less than 3 seconds.
- High Definition LCD Display: Clearly shows temperature, sugar content (Brix), and refractive index on the same screen.
- One-Key Zeroing: Easy calibration using clean water for improved accuracy.
- Language Switch: Toggle between Chinese and English interfaces.
- IP67 Certified: Waterproof and moisture-proof design for protection in various environments.
- High-Precision Metal Sample Cell: Easy to clean and corrosion-resistant for accurate measurements.
- Auto Shut-off: Power-saving feature.
- Low Power Consumption: Long battery life using AAA batteries.





Product Specifications
Model SW55S
| Parameter Name | Basic Parameters |
|---|---|
| Product Model | SW-55S |
| Measuring range | 0~55% Brix |
| Resolution | 0.1% Brix |
| Accuracy | ±0.2%, ±1°C |
| Temperature compensation | 10~40°C |
| Ambient temperature | 10~40°C |
| Battery | 2 x AA Batteries (Product does not include batteries) |
| Dimensions & Weight | 114x58x31mm, 127g |
Model SW93S
| Parameter Name | Basic Parameters |
|---|---|
| Product Model | SW-93S |
| Measuring range | 0~93% Brix |
| Resolution | 0.1% Brix |
| Accuracy | ±0.2% Brix / ±1°C |
| Temperature compensation | 10~40°C |
| Ambient temperature | 10~40°C |
| Battery | 2 x AA Batteries (Product does not include batteries) |
| Dimensions & Weight | 114x58x31mm, 127g |
Note: Manual measurement may have 1-2mm error, please refer to the actual received product.
Setup
1. Battery Installation
The refractometer uses 2 x AA batteries (not included). Open the battery compartment at the bottom of the device, insert the batteries according to the polarity markings, and close the compartment securely.
2. Zero-setting (Calibration)
Before each use, or if the instrument has not been used for a long time, perform a zero-setting calibration to ensure accuracy.
- Ensure the measuring slot is clean. If there is dirt or oiliness, clean it thoroughly with ethanol or soapy water, then rinse with clean water and wipe dry with paper towels.
- Drip about 0.3 ml of clean water or pure water into the measuring slot. Ensure there is about 1 mm between the water and the top of the measuring slot.
- Press and hold the "Zero" button for 1 second to perform the zero-setting.
- Check if the measured value displays 0.0%. If not, repeat the zero-setting process.

Operating Instructions
1. Measurement Steps
- Check precautions before measurement. Press the instrument switch key to start.
- Add the detection sample to the measuring slot. Ensure the sample fills at least half the volume of the cuvette.
- Press the "Meas" key to aspirate the solution.
- Repeat measurement several times to ensure data accuracy.
- Clean the sample slot thoroughly after each measurement and proceed to the next measurement.



2. Temperature Compensation
The device features automatic temperature compensation (ATC) for samples between 10°C and 40°C. This feature automatically adjusts readings to account for temperature variations, providing more accurate results.
3. Language Switching
To switch between Chinese and English interfaces, hold down the Power button and the Zero button simultaneously when powering on the device.
Maintenance
1. Cleaning
After each use, clean the measuring slot thoroughly. If the slot contains oiliness or has not been used for a long time, clean it with ethanol or soapy water, then rinse with clean water and wipe dry with paper towels. Ensure no residue remains.
The high-precision metal sample cell is designed for easy cleaning.
2. Storage
This instrument is a precise optical instrument. To maintain its accuracy and longevity, prevent it from collision and falling.
Forbid hard objects from scratching the optical prism in the measuring slot.
When not in use, store the refractometer in a dry place.
3. Battery Care
Replace batteries when the low power indicator appears on the display. Ensure correct battery polarity during installation.
Troubleshooting
| Error Message / Status Notice | Reason | Solution |
|---|---|---|
| High temperature | Temperature excess in measuring slot. | Allow the instrument and sample to reach ambient temperature (10-40°C) before measurement. |
| Low temperature | Temperature excess in measuring slot. | Allow the instrument and sample to reach ambient temperature (10-40°C) before measurement. |
| Re zero | Please follow the zero-clearing step again. | Perform zero-setting calibration as described in the "Zero-setting" section. |
| Less solution | Too little solution in measuring slot. | Ensure the sample fills at least half the volume of the cuvette. |
| Less water | Too little clean water in measuring slot (during zeroing). | Ensure sufficient clean water (approx. 0.3 ml) is used for zero-setting. |
| Out of range | Excessive concentration. | Dilute the sample if its concentration exceeds the measurement range of the device. |
| Low voltage | Low battery. | Replace the batteries. |
| Call maintenance | Possible damage to components. | If other issues persist after troubleshooting, contact customer support. |
Warnings
- This instrument is a precise optical instrument. Prevent it from collision and fall.
- Forbid hard objects to scratch the optical prism in the measuring slot.
- When it is out of use, please store it in a place as dry as possible.
- USB charging voltage should not exceed DC6V limit.
User Tips
- Ensure Sample Temperature Stability: For the most accurate results, especially with hot or cold liquids, allow the sample to sit in the measuring slot for at least 20 seconds to allow the instrument to compensate for temperature.
- Thorough Cleaning is Key: Always clean the sample slot with clean water and wipe dry after each measurement. For oily or sticky samples, use a mild soap solution or ethanol. This prevents residue buildup that can affect accuracy.
- Zero Calibration: Regularly perform a zero calibration with distilled or pure water to maintain the instrument's precision.
- Honey Measurement: While the device measures Brix (sugar content), it can be used for honey. However, for specific "water in honey" measurements, ensure you understand the correlation between Brix and water content for honey, as this device directly measures Brix.
Warranty and Support
Warranty Service
The company provides one-year non-man-made damage warranty service for customers from the date of purchasing the instrument.
Exclusions from Warranty
The following conditions are not included in the warranty:
- Artificial damage or damage caused by improper use and custody.
- Failure or damage caused by dismantling and assembling without authorization of the company.
- Instruments purchased through informal channels.
PDF User Manual
A detailed user manual in PDF format is available for download: View User Manual (PDF)