SWEVY SW55S/SW93S

Contents

SWEVY SW55S/SW93S Digital Brix Refractometer User Manual

Model: SW55S / SW93S

Brand: SWEVY

Introduction

This manual provides detailed instructions for the proper use and maintenance of your SWEVY SW55S/SW93S Digital Brix Refractometer. This high-precision instrument is designed for accurate measurement of sugar content (Brix), temperature, and refractive index in various solutions, including juices, milk tea, and other beverages. Its automatic temperature compensation and user-friendly interface ensure reliable results.

SWEVY SW93S Digital Brix Refractometer showing 10.0% Brix reading.
The SWEVY Digital Brix Refractometer offers high precision with a 0-93% Brix range and 0.1% resolution.

Key Features

  • High Precision: 0.1% Brix resolution for accurate readings.
  • Wide Measurement Range: Available in 0-55% Brix (SW55S) and 0-93% Brix (SW93S) models.
  • Automatic Temperature Compensation (ATC): Ensures accurate data by reducing errors caused by temperature differences (10-40°C).
  • Quick Results: Provides measurements in less than 3 seconds.
  • High Definition LCD Display: Clearly shows temperature, sugar content (Brix), and refractive index on the same screen.
  • One-Key Zeroing: Easy calibration using clean water for improved accuracy.
  • Language Switch: Toggle between Chinese and English interfaces.
  • IP67 Certified: Waterproof and moisture-proof design for protection in various environments.
  • High-Precision Metal Sample Cell: Easy to clean and corrosion-resistant for accurate measurements.
  • Auto Shut-off: Power-saving feature.
  • Low Power Consumption: Long battery life using AAA batteries.
Diagram showing key components and dimensions of the SWEVY SW93S refractometer.
Key components include the measurement slot, optical prism, LCD screen, power button, reset button, and measuring key. Dimensions are 114x58x31mm.
SWEVY refractometer illustrating automatic temperature compensation between 10°C and 40°C.
Automatic temperature compensation ensures more accurate measurements by adjusting for temperature differences.
SWEVY refractometer showing a quick measurement result in less than 3 seconds.
The device provides rapid measurement results, eliminating long waiting times.
SWEVY refractometer demonstrating Chinese-English language switch function.
Hold Power and Reset buttons simultaneously to switch between Chinese and English interfaces.
Diagram showing six superior qualities of the SWEVY refractometer: Temperature compensation, One-key zero setting, HD display, High-precision sensor, Auto Shut-off, Protection level IP67.
The refractometer boasts six core advantages including IP67 protection, large screen display, temperature compensation, one-key zero calibration, high-precision prism, and auto shutdown.

Product Specifications

Model SW55S

Parameter NameBasic Parameters
Product ModelSW-55S
Measuring range0~55% Brix
Resolution0.1% Brix
Accuracy±0.2%, ±1°C
Temperature compensation10~40°C
Ambient temperature10~40°C
Battery2 x AA Batteries (Product does not include batteries)
Dimensions & Weight114x58x31mm, 127g

Model SW93S

Parameter NameBasic Parameters
Product ModelSW-93S
Measuring range0~93% Brix
Resolution0.1% Brix
Accuracy±0.2% Brix / ±1°C
Temperature compensation10~40°C
Ambient temperature10~40°C
Battery2 x AA Batteries (Product does not include batteries)
Dimensions & Weight114x58x31mm, 127g

Note: Manual measurement may have 1-2mm error, please refer to the actual received product.

Setup

1. Battery Installation

The refractometer uses 2 x AA batteries (not included). Open the battery compartment at the bottom of the device, insert the batteries according to the polarity markings, and close the compartment securely.

Demonstration of battery installation and the device's low power consumption.

2. Zero-setting (Calibration)

Before each use, or if the instrument has not been used for a long time, perform a zero-setting calibration to ensure accuracy.

  1. Ensure the measuring slot is clean. If there is dirt or oiliness, clean it thoroughly with ethanol or soapy water, then rinse with clean water and wipe dry with paper towels.
  2. Drip about 0.3 ml of clean water or pure water into the measuring slot. Ensure there is about 1 mm between the water and the top of the measuring slot.
  3. Press and hold the "Zero" button for 1 second to perform the zero-setting.
  4. Check if the measured value displays 0.0%. If not, repeat the zero-setting process.
Diagram illustrating the zero-setting process with clean water.
Use clean water for zero adjustment to improve measurement accuracy. Press the 'Zero' button to calibrate.

Operating Instructions

1. Measurement Steps

  1. Check precautions before measurement. Press the instrument switch key to start.
  2. Add the detection sample to the measuring slot. Ensure the sample fills at least half the volume of the cuvette.
  3. Press the "Meas" key to aspirate the solution.
  4. Repeat measurement several times to ensure data accuracy.
  5. Clean the sample slot thoroughly after each measurement and proceed to the next measurement.
Four-step diagram showing the measurement operation steps for the SWEVY refractometer.
Measurement steps include checking precautions, adding sample, pressing 'Meas' key, and cleaning the slot.
SWEVY refractometer measuring sugar content of green jujube.
Example of measuring sugar content in green jujube, showing a result of 13.2% Brix.
SWEVY refractometer measuring sugar content of a beverage.
Example of measuring sugar content in a beverage, showing a result of 11.1% Brix.

2. Temperature Compensation

The device features automatic temperature compensation (ATC) for samples between 10°C and 40°C. This feature automatically adjusts readings to account for temperature variations, providing more accurate results.

3. Language Switching

To switch between Chinese and English interfaces, hold down the Power button and the Zero button simultaneously when powering on the device.

Maintenance

1. Cleaning

After each use, clean the measuring slot thoroughly. If the slot contains oiliness or has not been used for a long time, clean it with ethanol or soapy water, then rinse with clean water and wipe dry with paper towels. Ensure no residue remains.

The high-precision metal sample cell is designed for easy cleaning.

2. Storage

This instrument is a precise optical instrument. To maintain its accuracy and longevity, prevent it from collision and falling.

Forbid hard objects from scratching the optical prism in the measuring slot.

When not in use, store the refractometer in a dry place.

3. Battery Care

Replace batteries when the low power indicator appears on the display. Ensure correct battery polarity during installation.

Troubleshooting

Error Message / Status NoticeReasonSolution
High temperatureTemperature excess in measuring slot.Allow the instrument and sample to reach ambient temperature (10-40°C) before measurement.
Low temperatureTemperature excess in measuring slot.Allow the instrument and sample to reach ambient temperature (10-40°C) before measurement.
Re zeroPlease follow the zero-clearing step again.Perform zero-setting calibration as described in the "Zero-setting" section.
Less solutionToo little solution in measuring slot.Ensure the sample fills at least half the volume of the cuvette.
Less waterToo little clean water in measuring slot (during zeroing).Ensure sufficient clean water (approx. 0.3 ml) is used for zero-setting.
Out of rangeExcessive concentration.Dilute the sample if its concentration exceeds the measurement range of the device.
Low voltageLow battery.Replace the batteries.
Call maintenancePossible damage to components.If other issues persist after troubleshooting, contact customer support.

Warnings

  • This instrument is a precise optical instrument. Prevent it from collision and fall.
  • Forbid hard objects to scratch the optical prism in the measuring slot.
  • When it is out of use, please store it in a place as dry as possible.
  • USB charging voltage should not exceed DC6V limit.

User Tips

  • Ensure Sample Temperature Stability: For the most accurate results, especially with hot or cold liquids, allow the sample to sit in the measuring slot for at least 20 seconds to allow the instrument to compensate for temperature.
  • Thorough Cleaning is Key: Always clean the sample slot with clean water and wipe dry after each measurement. For oily or sticky samples, use a mild soap solution or ethanol. This prevents residue buildup that can affect accuracy.
  • Zero Calibration: Regularly perform a zero calibration with distilled or pure water to maintain the instrument's precision.
  • Honey Measurement: While the device measures Brix (sugar content), it can be used for honey. However, for specific "water in honey" measurements, ensure you understand the correlation between Brix and water content for honey, as this device directly measures Brix.

Warranty and Support

Warranty Service

The company provides one-year non-man-made damage warranty service for customers from the date of purchasing the instrument.

Exclusions from Warranty

The following conditions are not included in the warranty:

  • Artificial damage or damage caused by improper use and custody.
  • Failure or damage caused by dismantling and assembling without authorization of the company.
  • Instruments purchased through informal channels.

PDF User Manual

A detailed user manual in PDF format is available for download: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.