1. Introduction
This manual provides comprehensive instructions for the JIKONG JK-BD6A24S6PD Smart Active Balance Battery Management System (BMS). This advanced BMS is designed for various lithium battery types, including Li-Ion, LiFePO4, and LTO, supporting configurations from 8S to 24S with a 60A charge/discharge current. It features intelligent active balancing, robust protection mechanisms, and smart communication capabilities to ensure optimal battery performance and longevity.
For detailed technical specifications and further information, please refer to the official user manual PDF: JIKONG BMS User Manual (PDF).

2. Specifications
2.1. Product Parameters (Model JK-BD6A24S6PD)
| Attribute | Value |
|---|---|
| Brand Name | JIKONG |
| Model | JK-BD6A24S6PD |
| Handware or Smart | SMART BMS |
| Balance Function | Active Balanced BMS |
| Balance Current | 0.6A |
| Battery Series | 8S-24S |
| Charging Current | 60A |
| Discharge Current | 60A |
| Charge and Discharge Port | Common Port BMS |
| Type | LI-ION Battery BMS |
| Usage Scenario | Power BMS, Energy Storage BMS, 3C Digital BMS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
| Certification | CE |
| Bluetooth | YES |
| Origin | Mainland China |
2.2. Dimensions
- Length: 116.8 mm
- Width: 94.8 mm
- Height: 14.6 mm
- Weight: 327 g



2.3. Packing List

3. Setup & Installation
3.1. Pre-Installation Checklist
- Ensure all cables are connected correctly.
- Insert the main cable into the BMS.
- Connect the B-line and P-line to the battery.
- Verify that the balance cable is properly connected.
- Ensure P- and B- terminals are correctly connected.
- Confirm the protection board is securely fixed to the battery core.
3.2. Wiring Diagrams
The wiring method varies depending on the number of battery cells. Below are examples for 8-string and 4-string configurations.


3.3. Interface Definition
The BMS features various interfaces for communication and control. Refer to the detailed pin definitions in the official PDF manual (pages 18-21) for specific wiring of connectors P1, P2, P3, P4, and P5.

3.4. APP Installation
The JIKONG BMS can be managed via a mobile application. To install the APP, scan the QR code below. An Android device with version 7 or higher is required.

3.5. Device Activation
Before powering on the protection board, double-check all connections. The BMS is designed for charging activation mode, meaning it will activate when a charger (with voltage 2V higher than battery voltage) is connected to the battery pack. Alternatively, if you have an optional light panel, you can activate the device by connecting the panel and pressing its button.
4. Operating Instructions
4.1. Active Equalization
The BMS utilizes active equalization technology to balance cell voltages by transferring energy from higher-voltage cells to lower-voltage cells. Before using this function, set the battery type and basic parameters (number of cells, capacity, trigger equalization differential pressure, voltage calibration, current calibration) in the JIKONG BMS APP. The default balance current is 0.6A. You can adjust the balance current based on your battery capacity or disable the balancing function via the APP if not needed.


4.2. Communication Function
The BMS supports UART serial communication as standard and offers an optional one-wire communication feature. Users can configure the device address and communication protocol via the APP to suit their specific application needs. Detailed protocols are available in the Jikong Protection Board Communication Protocol Documentation.
4.3. LED Battery Level Display
The BMS has a reserved LED power level display function. An optional light panel can be configured to show the battery charge level. The panel includes an activation switch for turning the protection board on or off.
| SOC | LED1 | LED2 | LED3 | LED4 | LED5 |
|---|---|---|---|---|---|
| 0%-9% | ○ | ○ | ○ | ○ | ○ |
| 10%-19% | ● | ○ | ○ | ○ | ○ |
| 20%-39% | ● | ● | ○ | ○ | ○ |
| 40%-59% | ● | ● | ● | ○ | ○ |
| 60%-79% | ● | ● | ● | ● | ○ |
| 80%-100% | ● | ● | ● | ● | ● |
Legend: ● = Green (always on), ○ = Off
4.4. Protection Functions
The BMS provides comprehensive protection features:
- Charge Overvoltage Protection: Prevents overcharging by shutting off charging when any cell voltage exceeds the set limit. Charging resumes when all cells are below the recovery voltage.
- Discharge Undervoltage Protection: Prevents over-discharging by cutting off discharge when any cell voltage drops below the set limit. Discharge resumes when all cells are above the recovery voltage. The BMS will automatically shut down if any cell voltage falls below the automatic shutdown voltage.
- Charge Overcurrent Protection: Stops charging if the charging current exceeds the set continuous limit for a specified delay. Charging resumes after the overcurrent release time.
- Discharge Overcurrent Protection: Stops discharging if the discharge current exceeds the set continuous limit for a specified delay. Discharging resumes after the overcurrent release time. (Note: Maximum continuous discharge current should not exceed 60A for this model).
- Overtemperature Protection: Shuts off charging/discharging if the BMS temperature exceeds the set limit. Operation resumes when the temperature falls below the recovery threshold.
- Low Temperature Protection: Shuts off charging if the BMS temperature falls below the set low-temperature limit. Charging resumes when the temperature rises above the recovery threshold.
- Short Circuit Protection: Automatically triggers if a short circuit is detected during charging or discharging. The protection delay and recovery time can be configured via the APP.
4.5. Emergency Switch
In case of issues like over-temperature, over-discharge, or over-charge, activating the emergency switch in the BMS control page of the APP will enable charge and discharge for 30 minutes. This provides an emergency operational window, even if a single cell reaches automatic shutdown voltage, to prevent critical failures during use.
4.6. Intelligent Sleep
The intelligent sleep function, configurable via the APP, allows the BMS to enter a low-power state if the charging/discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's self-consumption. The BMS can be reactivated by pressing a button (if a light panel is connected) or by connecting a charger.
4.7. Parameter Setting
All operational parameters, including protection thresholds and delays, can be customized through the JIKONG BMS APP. Refer to the "Instructions for Setting Protection Board Parameters" section in the official PDF manual for detailed guidance on parameter configuration.

5. Maintenance
The JIKONG BMS is designed for durability with an aluminum alloy shell, providing anti-voltage and anti-vibration protection for internal components. Regular visual inspection for any physical damage or loose connections is recommended. Keep the BMS clean and free from dust and moisture to ensure optimal performance and longevity.

6. Troubleshooting
- BMS Not Activating: Ensure all wiring is correct and secure. Try activating by connecting a charger (voltage 2V higher than battery) or using the optional light panel's activation button.
- Frequent Protection Triggers:
- Overvoltage/Undervoltage: Check individual cell voltages. Adjust protection thresholds in the APP if necessary, ensuring they are within safe operating limits for your battery type.
- Overcurrent (Charge/Discharge): Verify that your charger/load current does not exceed the BMS's continuous current rating (60A). Adjust overcurrent delay and release times in the APP if transient current spikes are causing false triggers.
- Overtemperature/Low Temperature: Ensure proper ventilation and operating environment. Check NTC sensor connections. Adjust temperature thresholds in the APP if needed.
- Short Circuit: Double-check all external wiring for actual short circuits. If the issue is due to high instantaneous current from a load (e.g., large capacitor), increase the short circuit protection delay in the APP.
- Balancing Issues: Ensure active equalization is enabled in the APP and that battery parameters (cell count, capacity) are correctly set. Check the balance trigger differential pressure.
- Communication Problems (Bluetooth/UART): Ensure the APP is installed correctly and your mobile device's Bluetooth is enabled. Check the Bluetooth status indicator on the BMS. For UART, verify wiring and communication protocol settings.
7. User Tips
- Battery Compatibility: The JIKONG JK-BD6A24S6PD BMS is suitable for 8S-24S battery packs, which typically correspond to 24V, 48V, or 72V systems, and supports LiFePO4, Li-Ion, and LTO battery chemistries. Always verify your battery configuration matches the BMS specifications.
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters and balancing settings for your specific battery pack to maximize performance and lifespan.
- Initial Setup: Always perform a thorough check of all wiring connections before the initial power-on to prevent damage to the BMS or battery.
8. Warranty & Support
For information regarding warranty, returns, and technical support, please refer to the official JIKONG documentation provided with your product or contact JIKONG Official Store directly. Always retain your proof of purchase for warranty claims.