TSUN MA06LS

Contents

TSUN MA06LS Magnetic Grid Displacement Digital Display User Manual

Model: MA06LS

1. Introduction

The TSUN MA06LS is a magnetic grid displacement digital display designed for precise length and angle measurement. It features a non-contact measurement system, ensuring no wear and tear, and offers high protection against oil and dust. This manual provides essential information for the safe and efficient operation and maintenance of your device.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in injury or damage to the product.

  • Ensure the device is installed correctly and securely to prevent accidental movement.
  • Keep the device away from strong magnetic fields that could interfere with its operation.
  • Do not expose the device to extreme temperatures or corrosive environments.
  • Only use specified batteries for replacement.
  • Avoid direct contact with the magnetic sensor during operation.

3. Product Overview

3.1 Components

  • Digital Display Unit (MA06LS)
  • Magnetic Sensor with Cable
Front view of TSUN MA06LS digital display unit

Figure 3.1: Front view of the MA06LS Digital Display Unit

Back view of TSUN MA06LS digital display unit with magnetic sensor and cable

Figure 3.2: Back view of the MA06LS with Magnetic Sensor and Cable

3.2 Key Features

  • Measurement Modes: Metric/Imperial switchable, Length/Angle measurement.
  • Reference Modes: Absolute/Relative measurement.
  • Non-Contact: Ensures no wear and tear on components.
  • Durability: High protection level, resistant to oil and dust.
  • Construction: Beautiful aluminum alloy shell with four-corner extruded plastic fittings for easy installation.
  • Power: Convenient battery replacement.

3.3 Controls

Close-up of MA06LS display showing buttons P/F1, Up/F2, Down/F3, C/F4

Figure 3.3: MA06LS Control Buttons

  • P / F1: Program/Function 1 button.
  • ▲ / F2: Up/Function 2 button.
  • ► / F3: Right/Function 3 button.
  • C / F4: Clear/Function 4 button.

4. Setup

4.1 Physical Installation

The MA06LS display unit is designed for fixed type mounting. Use the provided plastic fittings for secure installation.

Dimensional drawing of MA06LS showing front and side views with measurements

Figure 4.1: MA06LS Dimensional Drawing (Front View: 73.7mm W x 36.2mm H; Side View 2: 67.6mm D; Side View 1: 32.1mm H x 4mm Flange Thickness)

  1. Prepare the mounting surface according to the dimensions provided in Figure 4.1.
  2. Insert the display unit into the prepared opening.
  3. Secure the unit using the four-corner extruded plastic fittings.
  4. Connect the magnetic sensor cable to the display unit.
  5. Mount the magnetic sensor parallel to the measurement axis, ensuring proper alignment with the magnetic grid (not included).

4.2 Powering On and Battery Installation

The device is battery-powered. Ensure batteries are correctly installed before first use.

  1. Locate the battery compartment on the back of the display unit.
  2. Open the compartment cover.
  3. Insert the required batteries, observing polarity.
  4. Close the battery compartment cover securely.
  5. The device should power on automatically or by pressing a designated power button (if available).

5. Operating Instructions

5.1 Basic Measurement

The MA06LS uses a magnetic sensor to detect displacement along a magnetic grid. As the sensor moves, the display updates the measurement.

Video 5.1: Demonstration of a similar TSUN digital display (MA06L) showing displacement measurement.

  1. Ensure the magnetic sensor is properly aligned with the magnetic grid.
  2. Move the sensor along the desired path. The display will show the real-time displacement.

5.2 Mode Selection (Metric/Imperial)

To switch between metric (mm) and imperial (inch) units:

  • Press the appropriate button (often labeled 'mm/inch' or similar, or a function key like F3/F4 as seen on some models) to toggle between units. Refer to the specific button layout of your MA06LS model.

5.3 Absolute/Relative Measurement

The device supports both absolute and relative measurement modes:

  • Absolute Mode: Measures displacement from a fixed origin.
  • Relative Mode: Allows setting a temporary zero point for incremental measurements.
  • Use the 'ABS/REL' button (or corresponding function key) to switch between these modes.

5.4 Zeroing/Resetting

To set the current position as zero:

  • Press the 'C' (Clear) or 'F4' button to reset the display to zero at the current sensor position.

6. Maintenance

6.1 Cleaning

  • Wipe the display and sensor with a soft, dry cloth.
  • For stubborn dirt, use a slightly damp cloth with mild detergent, then dry thoroughly.
  • Do not use abrasive cleaners or solvents.

6.2 Battery Replacement

When the battery indicator shows low power or the display becomes dim, replace the batteries.

Back view of MA06LS with Chinese text warning about battery replacement

Figure 6.1: Battery Replacement Warning (Chinese text: "When replacing the battery, please replace them one by one to avoid losing current data.")

  1. Power off the device if possible, or proceed carefully to avoid data loss.
  2. Open the battery compartment.
  3. Important: Replace batteries one by one to prevent loss of current measurement data.
  4. Insert new batteries, ensuring correct polarity.
  5. Close the battery compartment securely.

6.3 Storage

  • Store the device in a dry, clean environment, away from direct sunlight and extreme temperatures.
  • If storing for an extended period, remove the batteries to prevent leakage.

7. Troubleshooting

Problem Possible Cause Solution
No display or dim display Low or dead batteries; incorrect battery installation. Replace batteries, ensuring correct polarity.
Inaccurate readings Sensor misalignment; magnetic interference; dirty sensor/grid. Check sensor alignment, move away from magnetic sources, clean sensor and magnetic grid.
Display shows "E07" Error code, possibly related to sensor connection or internal fault. Check sensor cable connection. If the issue persists, contact customer support.
Buttons unresponsive Device frozen; low battery. Remove and reinsert batteries. Replace batteries if low.

8. Specifications

Attribute Value
Brand TSUN
Model Number MA06LS
Material Stainless steel (sensor component)
Type Fixed type, Digital display meter
Mounting Type Fixed type
Theory Digital display
Usage Measurement
Display Unit Dimensions (Front) 73.7mm (Width) x 36.2mm (Height)
Display Unit Dimensions (Depth) 67.6mm
Mounting Flange Thickness 4mm

9. Warranty and Support

For technical support, service inquiries, or warranty claims, please contact the manufacturer or your local distributor.

Contact Information:

  • Company: Jinan Ouna Electrical and Mechanical Equipment Co., Ltd.
  • Email: yvonneyihua@gmail.com
  • Phone/WhatsApp/WeChat: +86 19083360331
  • Address: D12-103, Lanxiang Road Times Headquarters Base, Tianqiao District, Jinan City, Shandong Province
Contact information for Jinan Ouna Electrical and Mechanical Equipment Co., Ltd.

Figure 9.1: Contact Information

10. User Tips

  • For consistent readings, ensure the magnetic grid and sensor are free from debris and moisture.
  • Periodically check the battery level to avoid unexpected power loss during critical measurements.
  • When installing, ensure the sensor is perfectly parallel to the magnetic strip for optimal accuracy.
  • Familiarize yourself with the function keys (F1-F4) as they may offer advanced settings or calibration options depending on the specific firmware version.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.