1. Introduction
The BSIDE O2 is a state-of-the-art dual-channel touch-screen oscilloscope and signal generator, designed for professionals in maintenance and R&D. This device integrates comprehensive functions with high practicality, offering advanced measurement capabilities in a portable form factor.
It features an FPGA+MCU+ADC hardware architecture, providing a real-time sampling rate of 250MSa/s and an analog bandwidth of 50MHz. A built-in high-voltage protection module ensures safety, supporting a maximum peak voltage measurement of ±400V. The device also allows for waveform screenshots, saving, and viewing for secondary analysis.
The integrated DDS function signal generator can output 12 types of function signals, with a maximum output frequency of 2MHz (1Hz step), and adjustable output frequency, amplitude, and duty cycle.
Equipped with a 3.98-inch touch display and a 3000mAh rechargeable lithium battery, the BSIDE O2 offers up to 7 hours of standby time, combining powerful features with excellent portability.
2. Setup
2.1 Unboxing and Initial Inspection
Carefully unpack the BSIDE O2 device and all accessories. Verify that all components listed in the 'Package Inclusions' section are present and undamaged.

Image: BSIDE O2 device with included probes, USB cable, manual, and carrying case.
2.2 Charging the Device
Before first use, fully charge the device. Connect the provided USB Type-C cable to the device's charging port and a 5V/2A power adapter (not included). The battery indicator on the screen will show charging status.

Image: Close-up of the Type-C data transfer and charging port on the device.
2.3 Attaching Probes
Connect the oscilloscope probes to the OSC 1 and OSC 2 BNC connectors at the top of the device. Ensure a secure connection. For multimeter functions, use the multimeter probe.
2.4 Powering On/Off
Press and hold the power button (usually located on the side or bottom) to turn the device on or off. The device features an automatic power-off function to conserve battery.
Video: A demonstration of unboxing, powering on, and basic touch screen interaction with the BSIDE O2.
3. Operating Instructions
3.1 General Interface and Navigation
The BSIDE O2 features a 3.98-inch full touch screen for intuitive operation. You can interact directly with the display to adjust settings and view waveforms. Additionally, a 'Function Wheel' provides an alternative method for navigation and parameter adjustment.

Image: The touch screen interface displaying waveform analysis and measurement data.
3.2 Oscilloscope Functions
The oscilloscope mode allows for detailed analysis of electrical signals.
- Dual Channel Operation: The device supports two independent channels (OSC 1 and OSC 2) for simultaneous waveform display and comparison.
- Parameter Adjustment: Use the touch screen or function wheel to adjust settings such as Voltage Scale (V/div), Time Base (s/div), and Trigger Level.
- Trigger Modes: Select from AUTO, Normal, or Single trigger modes. Trigger types include Rising Edge and Falling Edge.
- Waveform Display: View waveforms in XY, YT, or Scroll modes.
- Measurements: The device can automatically measure various parameters including Period, Frequency, Peak-to-Peak value, Maximum value, Minimum value, Average value, Effective value, Amplitude, Duty Cycle, and Pulse Width.
- Math Calculations: Perform mathematical operations on waveforms such as 1+2, 1-2, 1*2, 1/2, -1, -2, |1|, |2|, and FFT.
- Waveform Saving: The built-in 120Mbit storage space can save up to 250 waveforms and 90 screenshots for later review.
- PC Connection: Easily connect the device to a PC via the USB Type-C cable to export waveform images and conduct secondary analysis.

Image: Detailed diagram of the LCD panel interface, showing display elements and menu navigation options for oscilloscope functions.

Image: The BSIDE O2 connected to a laptop, demonstrating one-click mastery of waveform data and PC connectivity for secondary analysis.
3.3 Signal Generator Functions
The integrated signal generator can produce various waveforms for testing and calibration.
- Waveform Types: Output 12 kinds of function signals including sinusoidal wave, square wave, sawtooth wave, half wave, full wave, positive step wave, negative step wave, DC signal, exponential rise, exponential fall, multi-audio, and sync pulse.
- Adjustable Parameters: Set the output frequency (0-2MHz, with sine wave up to 10MHz and other waveforms up to 5MHz), amplitude (0.1V-3.0V), and square wave duty cycle (0-99%).
- Simultaneous Operation: The signal generation function can be performed simultaneously with the oscilloscope function.

Image: Illustration of the signal generator output and the touch interface for adjusting waveform parameters.

Image: A visual representation of the multiple waveform types that the BSIDE O2 signal generator can produce.
3.4 Language Switching
The device supports both English and Chinese languages. To switch, long-press the menu key to enter the menu, navigate to 'language selection', and select your preferred language.

Image: Depiction of the language switching functionality between Chinese and English.
4. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using abrasive cleaners or solvents.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period.
- Firmware Upgrades: The device supports firmware upgrades. Check the official BSIDE website for the latest firmware versions and instructions.
- Storage: Store the device in its carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
5. Troubleshooting
If you encounter issues with your BSIDE O2, consider the following general troubleshooting steps:
- Device not powering on: Ensure the battery is sufficiently charged. Connect the device to a power source using the Type-C cable and try again.
- No waveform display: Check that probes are correctly connected to both the device and the circuit under test. Verify that the input signal is within the device's measurement range.
- Inaccurate readings: Ensure probes are properly calibrated (if applicable) and that the correct probe attenuation (1x/10x) is selected on both the probe and the device.
- Touch screen unresponsive: Restart the device. If the issue persists, ensure the screen is clean and free of debris.
- Connectivity issues with PC: Ensure the USB Type-C cable is securely connected. Try a different USB port or cable.
For persistent issues, refer to the detailed troubleshooting section in the full product manual (if available) or contact BSIDE customer support.
6. Specifications

Image: Detailed technical specifications for the oscilloscope, signal generator, and general device parameters.
6.1 Oscilloscope Technical Indicators
| Characteristic | Instruction |
|---|---|
| Bandwidth | 50MHz |
| Digital Channels | 2 |
| Sampling Rate | 250MSa/s |
| Storage Depth | Up to 128kByte |
| Input Impedance | 1MΩ |
| Coupling | DC/AC |
| Maximum Input Voltage | ±400V (X10 probe) |
| Time Base Range | 10ns/div - 20s/div |
| Vertical Sensitivity | 10mV/div - 20V/div |
| Trigger Mode | AUTO/Normal/Single |
| Trigger Type | Rising edge, Falling edge |
| Waveform Display Mode | XY, YT, Scroll |
| Battery Included | Yes |
| IS Battery Demountable | No |
6.2 Signal Generator Technical Indicators
| Characteristic | Instruction |
|---|---|
| Waveform Type | Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Negative step wave, DC signal, Exponential rise, Exponential fall, Multi-audio, Sync pulse |
| Frequency Range | 0Hz-2MHz (Sine wave: 10MHz, other waveforms 5MHz) |
| Output Channels | 1 |
| Output Amplitude | 0.1V~3.0V |
| Square Wave Duty Cycle | 1%~99% |
6.3 General Parameters
| Characteristic | Instruction |
|---|---|
| Display Size | 3.98 Inches |
| Display Resolution | 480*320 pixels |
| Screen Material | Surface tempered glass + TFT color screen |
| Power Supply | TYPE-C (5V/2A) |
| Battery | 3000mAh lithium battery |
| Language | English/Chinese |
| Product Size | 170.0 x 80.9 x 23.9 mm |
| Product Net Weight | 268g |
| Certification | CE, FCC, RoHS |
| DIY Supplies | Electrical |
| Origin | Mainland China |
7. User Tips
- Portability: The compact size (170.0 x 80.9 x 23.9 mm) and light weight (268g) make the BSIDE O2 easy to carry in a pocket or toolkit, replacing bulkier equipment.
- Enhanced Durability: The device features a full silicone sheath for protection and a high permeability hardening material for the screen, ensuring durability in various working environments.
- Intelligent Anti-Burning: Benefit from the intelligent anti-burning feature designed to protect the device from accidental overloads.
- Data Analysis: Utilize the USB Type-C connection to easily transfer waveform data to a PC for more in-depth secondary analysis and professional reporting.
- Waveform Storage: Take advantage of the 120Mbit internal storage to save up to 250 waveforms and 90 screenshots for future reference or comparison.
8. Warranty and Support
The BSIDE O2 comes with a 12-month warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact BSIDE customer service through their official channels. Refer to the product packaging or the official BSIDE website for contact details.