FD DL2-WLTE-T&TVC

Contents

Smart Controller 4G LTE DL2-WLTE-T&TVC User Manual

Model: DL2-WLTE-T&TVC | Brand: FD

1. Overview

The FD Smart Controller 4G LTE DL2-WLTE-T&TVC is a versatile remote control device designed for managing various high-power equipment. It supports control via SMS, calls, a dedicated mobile application (WLTE Control), and a web interface. Key features include a 30A relay output, temperature sensor linkage, timing control, and an optional power failure alarm (available on DL2-WLTE-TVC version).

DL2-WLTE-TVC 4G Remote Controller with included accessories: antenna and power cable.
DL2-WLTE-TVC 4G Remote Controller with included accessories: antenna and power cable.
Smart Controller 4G LTE features: 30A relay output, Dial/SMS control, Web control, APP control, Temperature linkage, Power failure SMS alert.
Smart Controller 4G LTE features: 30A relay output, Dial/SMS control, Web control, APP control, Temperature linkage, Power failure SMS alert.

The controller operates on a 4G LTE network, providing unlimited distance control and alarm notifications. It is suitable for a wide range of applications including agriculture, home automation, industrial control, base station management, solar energy projects, and door/gate openers.

Detailed overview of the DL1-WLTE-TVC 4G remote controller's ports and indicators, including COM, NO, NC, Temp, STA, SIG, ANT, SIM, SW1, Key, and DC Power In.
Detailed overview of the DL1-WLTE-TVC 4G remote controller's ports and indicators.

2. Technical Specifications

FeatureSpecification
Model NumberDL2-WLTE-T/TVC
Brand NameFD
OriginMainland China
DC Power SupplyStandard adapter DC12V 1A (DC 7-36V input range)
Power ConsumptionStandby 12V/50mA, Working Max 12V/200mA
4G Frequency (LTE-FDD)B1/B3/B5/B7/B8/B20
GSM Frequency900/1800mhz
SIM InterfaceMicro SIM card
Antenna InterfaceStandard SMA interface
Temperature Sensor Interface1 sensor port
Temperature Detection Range-40℃ to 120℃
Relay Output2 channels, 30A/30VDC, 30A/250VAC, 30A/125VAC
Output LogicNormally open and normally closed
Shell Size115mm x 90mm x 40mm
Box Size145mm x 127mm x 45mm
Power Failure AlarmOptional (Available on DL2-WLTE-TVC version only)
Detailed product parameter table for the DL2-WLTE-T&TVC Controller.
Detailed product parameter table for the DL2-WLTE-T&TVC Controller.

3. Installation & Initial Setup

3.1 Physical Installation

The controller supports multiple installation methods:

  • DIN35mm Rail Installation: Mount the device onto a standard DIN35mm rail.
  • Screw Installation: Secure the device using screws. The mounting dimensions are 115mm x 90mm.
Installation methods: DIN35mm rail mounting and screw installation with dimensions (115mm x 90mm).
Installation methods: DIN35mm rail mounting and screw installation.

3.2 SIM Card Insertion

  1. Ensure the controller is powered off before inserting the SIM card.
  2. If your Micro SIM card has a PIN code, please disable it using a mobile phone before inserting it into the controller.
  3. Locate the Micro SIM card slot on the device.
  4. Insert the SIM card into the slot until you hear a 'ticking' sound, indicating it is securely in place.
  5. To remove the SIM card, push it in again until it 'pops out'.

3.3 Power On

Connect a DC 12V power adapter to the DC power input port (7-36V DC compatible). Ensure the power supply is stable.

3.4 Connecting to the 4G Network

After powering on, observe the SIG indicator:

  • If the SIG LED flashes once per second, it indicates connection to the GSM network.
  • If the SIG LED flashes once every two seconds, it means the device is successfully connected to the 4G network.
  • If the SIG LED remains constantly on, it indicates no access to the network. In this case, check the SIM card installation, antenna connection, and ensure the SIM service is active and has data. You may need to configure APN settings (see Troubleshooting).

4. Operation Modes

4.1 SMS Control

The controller can be managed via SMS commands. SMS control is not limited to authorized mobile phone numbers if the password is correct; any SMS command can enter the device.

Note: RLO (feedback SMS when input action) is only valid after APP input control is set and push is activated.

FunctionMessage FormatController ResponseDescription
Setup New Password (default pwd: 0000)SN0000NEW1234NEW SN SETOK NEW SN IS 1234SN + password (4 numbers) + NEW + new password.
Setup Authorized Number (up to 99 groups)SN0000SET09#1370000000009 number is 13888889999SN + password (4 numbers) + SET + **(Serial Number) + #Phone number
Inquiry the Authorized NumberSN0000CNK0909 number is 13888889999SN + password (4 numbers) + CNK + **(Serial Number)
Remove the Authorized NumberSN0000DEL0909 number deletedSN + password (4 numbers) + DEL + **(Serial Number)
Remove ALL Authorized NumbersSN0000DELALLALL numbers deletedSN + password (4 numbers) + DEL + ALL
Control the relay ON by SMS commandSN0000ONSTATUS IS ALL ON, temp is:+24.7CSN + password (4 numbers) + ON
Control the relay OFF by SMS commandSN0000OFFSTATUS IS ALL OFF, temp is:+24.7CSN + password (4 numbers) + OFF
Setup the trigger timeSN0000L01T000101 time is 0001 seconds.SN+password+L+01+T+length (length: 1-1000(seconds)), 001 second is default
Control the relay trigger by SMS commandSN0000TGCSTATUS IS trigger.SN + password (4 numbers) + OTG + C/X (Status: C:trigger ; X:Ignore)
Activate feedback SMS when input actionSN0000RLOINPUI-LINKAGE NUMS: 1:17062167530; 2:; 3:; 4:;SN + password (4 numbers) + RLO
Disable SMS replies when input actionSN0000RLCINPUI-LINKAGE NUMS: 1:; 2:; 3:; 4:;SN + password (4 numbers) + RLC
Enable power-off reminder SMSSN0000DLOREMINDED NUMS: 1:17062167530; 2:; 3:; 4:;This command is only for DL1-WLTE-TVC
Disable power-off reminder SMS (default)SN0000DLCREMINDED NUMS: 1:; 2:; 3:; 4:;This command is only for DL1-WLTE-TVC
Setting temperature control (Up to 8 groups)SN0000LEA01P00256NTAO1:LE+25.6 SW1:ONSN + password (4 numbers) + LE/GR + A + Group number (01-08) + P/N + *****(*****is the Thousands, hundreds, tens, ones and decimal + Relay code (N/F/X)
JOG relay via dialing (pulse relay for few seconds, then return to initial state)SN0000TXOJOG FUNCTION IS ON.SN + password (4 numbers) + TXO
Invert relay via dialing (default)SN0000TXCJOG FUNCTION IS OFF.SN + password (4 numbers) + TXC
Any phone can control the deviceSN0000DIOAny phone control SW1 function onSN + password (4 numbers) + DIO
Only authorized number can access the device (default)SN0000DICAny phone control SW1 function offSN + password (4 numbers) + DIC
Check APN settings and relay statusSN0000CHECKapn: user: pass: ; N;T:26.8CSN + password (4 numbers) + CHECK
Enable dial control feedback SMS (default)SN0000CBOMESSAGE FUNCTION IS ONSN + password (4 numbers) + CBO
Disable dial control feedback SMSSN0000CBCMESSAGE FUNCTION IS OFFSN + password (4 numbers) + CBC
Power-off memory ON (default) (Relay status remains consistent with pre-power-off)SN0000PAMrelay power down memory has been activated.SN + password (4 numbers) + PAM
Power-off memory OFFSN0000PAFrelay always forced to be off when power on.SN + password (4 numbers) + PAF
SMS control examples for various devices like electric heaters, water pumps, Ethernet switches, and charging piles.
SMS control examples for various devices.

4.2 APP Control (WLTE Control)

The WLTE Control app provides a convenient, intelligent, and handy way to manage your device. The app communicates with the controller via 4G internet access.

4.2.1 App Download

The app is named "WLTE Control".

  • Android: Search for "WLTE Control" in the Google Play Store or use the following link: Google Play Store
  • iPhone: Search for "WLTE Control" in the Apple App Store or use the following link: Apple App Store
  • Alternatively, you can download the app via the usage guide link: APP Usage Guide
QR codes for downloading the WLTE Control App for iPhone and Android, and a link for the APP usage guide.
QR codes for downloading the WLTE Control App and usage guide.

4.2.2 Adding Devices to the App

The default password for adding devices to the app is 1234.

WLTE Control App interface screenshots showing login, device control, and timing settings.
WLTE Control App interface screenshots.

4.3 Web Control

Centralized control of equipment is possible via a web browser on a PC.

Web control interface for centralized equipment management and short-time trigger switch function for applications like garage doors.
Web control interface and short-time trigger function.

4.4 Temperature Linkage

The controller can monitor real-time temperature. When the temperature reaches a preset value, it can trigger the relay switch (on/off) and send temperature alarm messages (SMS/APP/Email).

4.5 Timing Control

Set up to 24 groups of timing controls to automate equipment operation (e.g., turn on/off at specific times daily or on certain days).

4.6 Short-time Trigger (Inching)

This function allows for a short-duration relay activation (1 to 9 seconds settable), suitable for applications like controlling electric gates or garage doors.

4.7 Power Failure Alarm (DL2-WLTE-TVC only)

The DL2-WLTE-TVC version includes a power failure alert function. Upon power failure or restoration, you can receive an SMS/APP/Email alert.

Advanced functions: Power failure alert (for DL2-WLTE-TVC), email notifications for temperature, and APP push notifications for device status.
Advanced functions: Power failure alert, email notifications, and APP push notifications.

5. Wiring Instructions

Refer to the following diagrams for connecting the controller to various devices. Always ensure power is disconnected before performing any wiring.

Comprehensive wiring diagrams for various applications: low power lamp (AC220V), DC motor (DC 12-120V), high-power AC motor (AC 220/380V), electronic lock, DC motor forward and reverse control, and three-phase motor forward and reverse control.
Comprehensive wiring diagrams for various applications.
  • Low Power Lamp or Home Appliance (AC 220V): Connect the lamp/appliance to the relay's COM and NO terminals, with the AC 220V power supply.
  • DC Motor or Equipment Application (DC 12-120V): Connect the DC motor/equipment to the relay's COM and NO terminals, with the DC 12-120V power supply.
  • High-Power AC Motor/Equipment Application (AC 220/380V): For high-power AC loads, use an AC contactor. The controller's relay output (COM, NO) triggers the AC contactor, which then controls the high-power AC motor.
  • Trigger to Control Electronic Lock: Connect the electronic lock to the relay's COM and NO terminals. The relay acts as a switch to open/close the lock.
  • DC Motor Forward and Reverse Control: This requires two relays. One relay controls forward rotation (Channel 1 ON, Channel 2 OFF), and the other controls reverse rotation (Channel 1 OFF, Channel 2 ON). Ensure the power of the DC motor is less than 80W.
  • Three-Phase Motor Forward and Reverse Control (380V): This setup requires two AC contactors for controlling the forward and reverse rotation of a three-phase AC motor. The controller's relays activate the respective contactors.

6. Troubleshooting

6.1 Network Connection Issues

If the SIG LED is constantly on, indicating no network access:

  1. Verify that the Micro SIM card is correctly inserted and activated with a data plan.
  2. Ensure the antenna is securely connected.
  3. Check the APN settings. The default APN is "internet" with empty username and password. If this doesn't match your country's provider, you need to set it manually via SMS.

How to set APN via SMS:

Command format: SN+password+APN+length of APN=APN content, length of user=user content, password length =password content

Example: For APN: datelo.com.br, user: algar, password: 12345, send: SN0000APN13=datelo.com.br,05=algar,05=12345

To set parameters to null (empty), use 00=0. Example: SN0000APN05=cmnet,00=0,00=0

6.2 SMS Feedback Issues (KT Command)

If you are not receiving SMS feedback in certain situations, the KT mode might be closed. Try setting KT mode:

Command format: SN+password+KT+length of country code+S+country code+L+length of number

Example (France, country code 33, number length 9): SN0000KT2S33L09

To close KT mode, send: SN0000KTC

6.3 App Connection Issues

Ensure the device is successfully connected to the 4G network (SIG LED flashing once every two seconds). If not, resolve network issues first.

7. Maintenance

  • Keep the device in a dry, clean environment, away from direct sunlight and extreme temperatures.
  • Avoid exposing the device to water or excessive moisture.
  • Clean the exterior of the device with a soft, dry cloth. Do not use harsh chemicals or solvents.
  • Ensure all connections (power, antenna, SIM card, relay outputs) are secure and free from corrosion.

8. Warranty & Support

Most products from this store come with a 1-year warranty.

For detailed instructions and further support, please refer to the official user manual in PDF format:

View User Manual (PDF)

9. Important Notes

  • The DL2-WLTE-T version does NOT include the power failure alarm function. This feature is exclusive to the DL2-WLTE-TVC model.
  • Always disconnect power before performing any wiring or SIM card insertion/removal.
  • Ensure your Micro SIM card has no PIN code enabled before insertion.
  • For optimal performance, ensure a strong 4G signal in the installation area.
DL2-WLTE-T version of the 4G remote controller, noting it does not include the power failure alarm function.
DL2-WLTE-T version (without power failure alarm function).