FD DL1-WLTE-T

Contents

DL1-WLTE-T 4G LTE Temperature Sensor & 2 Relay Controller User Manual

Model: DL1-WLTE-T

1. Introduction

The DL1-WLTE-T is a versatile 4G LTE remote controller designed for managing various electrical equipment. It features a 30A relay output, temperature monitoring with alarm functions, and multiple control methods including SMS, phone calls, a dedicated mobile application, and web interface. This device is suitable for a wide range of applications, from home appliances to industrial equipment and agricultural systems.

DL1-WLTE-T 4G remote controller with antenna and SIM card slot, showing applications for home appliances.
Figure 1: DL1-WLTE-T 4G Remote Controller Overview
DL1-WLTE-TVC 4G remote controller, angled view, highlighting features like 30A relay, dial/SMS/web/app control, temperature linkage, power failure alert.
Figure 2: DL1-WLTE-TVC Smart Controller Features

2. Main Features

  • 4G LTE Connectivity: Requires a local 4G LTE SIM card for remote operation.
  • 30A Relay Output: Capable of controlling high-power equipment.
  • Temperature Monitoring: Integrated temperature sensor with alarm and linkage functions.
  • Multiple Control Methods: Control via SMS, phone calls, dedicated mobile App (WLTE Control), and web interface.
  • Inching/Short-time Trigger: Ideal for controlling electric gates or garage doors.
  • Timing Control: Schedule equipment operation.
  • Power Failure Alert (TVC Version Only): The TVC version includes a power failure message alert function. The T version does not.

3. Setup

3.1 Unpacking and Inspection

Before installation, carefully unpack the device and inspect for any signs of damage. Ensure all components are present:

  • DL1-WLTE-T/TVC Controller
  • Antenna
  • DC12V Power Adapter (if included with your version)
  • USB Cable (for certain configurations/updates, if included)
DL1-WLTE-T controller (T version without power failure alarm) with antenna and USB cable.
Figure 3: DL1-WLTE-T Version (without power failure alarm) and accessories

3.2 SIM Card Installation

  1. Ensure the controller is powered off.
  2. Locate the Micro SIM card slot on the device.
  3. Insert a local 4G LTE Micro SIM card into the slot. Ensure it is correctly oriented and securely seated.

3.3 Antenna Connection

Screw the provided antenna onto the SMA interface connector labeled "ANT" on the controller.

3.4 Mounting the Controller

The controller supports two installation methods:

  • DIN35mm Rail Installation: Attach the controller to a standard DIN35mm industrial rail.
  • Screw Installation: Use screws to mount the controller to a flat surface. Refer to the diagram for screw hole locations and dimensions (115mm x 90mm).
Installation method showing DIN35mm rail and screw installation options for the controller.
Figure 4: Installation Methods (DIN35mm and Screw)

3.5 Wiring Connections

Connect your equipment to the relay output terminals (COM, NO, NC) and provide DC power to the device. Ensure all connections are secure and follow local electrical codes. The relay output is rated for 30A/30VDC, 30A/250VAC, and 30A/125VAC.

Power Input: DC 7-36V (Standard adapter DC12V 1A recommended).

Below are common wiring examples:

Wiring diagrams for connecting the controller to a low power lamp (AC 220V), a DC motor (DC 12/24V), a high-power AC motor (AC 220/380V via contactor), and an electronic lock.
Figure 5: Example Wiring Diagrams for Various Applications
  • Low Power Lamp or Home Appliance: Direct connection to AC 220V.
  • DC Motor or Equipment: Direct connection to DC 12/24V.
  • High-power AC Motor/Equipment: Requires an external AC contactor for AC 220/380V applications.
  • Trigger to Control Electronic Lock: Connect the switch and electronic lock as shown.

Temperature Sensor: Connect the temperature sensor to the designated sensor port. The device supports 1 sensor port with a detection range of -40℃ to 120℃.

Input Interface: The device has 2 input interfaces (GND, 1, 2) for external triggers or monitoring.

4. Operating Instructions

The DL1-WLTE-T controller offers several methods for remote operation.

4.1 Dial Control

You can control the device by making a phone call to the SIM card number inserted in the controller. The device will recognize authorized numbers and execute commands (e.g., toggle relay state).

A smartphone screen showing an outgoing call, with icons of an electric heater, water heater, electric fan, and electric door, indicating control via dialing.
Figure 6: Dial Control for various appliances

4.2 SMS Control

Send specific SMS commands to the controller's SIM card number to control connected equipment. The device will respond with status messages.

A smartphone screen showing SMS commands being sent to control devices like an electric heater, water pump, Ethernet switch, and charging pile.
Figure 7: SMS Control for various equipment

4.3 Mobile App Control (WLTE Control)

Download and install the "WLTE Control" app on your smartphone for convenient and intelligent control. The app allows for device management, sensor monitoring, timing settings, and receiving notifications.

Screenshots of the WLTE Control app interface, showing login, device list, control toggles, temperature display, timing settings, and other features.
Figure 8: WLTE Control App Interface
Detailed screenshots of the WLTE app interface for device management, sensor recording, input control, push record, operation record, equipment location, and adding devices.
Figure 9: App Instruction and Features
  • Function 1: 30A Relay Output: Directly drive AC motors below 3KW.
  • Function 2: Temperature Control: Monitor real-time temperature. Trigger relay switch and send alarm messages when temperature exceeds set limits.
  • Function 3: Time Control: Set up to 24 groups of timing schedules for daily or specific day operations.
  • Function 4 (TVC Version Only): Power Failure Alert: Receive SMS/APP/Email alerts upon power failure or restoration.
  • Function 5: E-Mail Pushing: Receive email notifications when temperature reaches preset values.
  • Function 6: APP Pushing: Get app notifications to stay informed about device status.
App features detailing 30A relay output, temperature control with alarm, and time control with examples like turning on a kettle or water heater.
Figure 10: App Features (Relay, Temperature, Timing)
App features detailing power failure alert (TVC version), email pushing for temperature, and app push notifications for device status.
Figure 11: App Features (Alerts and Notifications)

4.4 Web Control

The device can be centrally controlled via a web browser on a PC, offering a comprehensive interface for managing equipment.

A laptop screen showing a web interface for centralized control of equipment, with ON/OFF toggles and status indicators.
Figure 12: Web Control Interface

4.5 Short-time Trigger Switch (Inching)

This function allows for a brief activation of the relay (1 to 9 seconds settable), suitable for applications like opening garage doors. This allows you to trigger the action and then automatically switch off after a set duration.

A smartphone screen showing a short-time trigger switch interface, with a car approaching a garage door, illustrating remote garage door opening.
Figure 13: Short-time Trigger for Garage Door Control

5. Maintenance

  • Keep the device clean and free from dust and moisture.
  • Regularly check all wiring connections for tightness and integrity.
  • Ensure the antenna is securely connected for optimal signal reception.
  • Periodically verify the functionality of connected sensors and controlled equipment.
  • For optimal performance, ensure the SIM card has an active data plan and sufficient balance.

6. Troubleshooting

  • Device not responding to commands:
    • Check if the SIM card is properly inserted and has an active 4G LTE data plan and sufficient credit.
    • Verify the power supply to the controller.
    • Ensure the antenna is connected and in an area with good 4G signal.
    • Confirm that the phone number or app is correctly configured and authorized.
  • Temperature alerts not received:
    • Check the temperature sensor connection.
    • Verify temperature threshold settings in the app or via SMS commands.
    • Ensure notification settings (SMS, App push, Email) are correctly configured.
  • Relay not switching:
    • Check the wiring to the connected equipment and the relay output terminals.
    • Ensure the load does not exceed the relay's maximum ratings (30A/30VDC, 30A/250VAC, 30A/125VAC).
    • Test the control command again.
  • Power failure alert not working (TVC version):
    • Ensure you have the TVC version of the controller.
    • Verify the power failure alert settings are enabled in the app or via SMS.

7. Specifications

ParameterValue
DC Power SupplyStandard adapter DC12V 1A
Power ConsumptionStandby 12V/50mA, Working Max 12V/200mA
4G Frequency (LTE-FDD)B1/B3/B5/B7/B8/B20
GSM Frequency900/1800mhz
SIM InterfaceMicro SIM card
Antenna InterfaceStandard SMA interface
Temperature Sensor Interface1 sensor port
Temperature Detection Range-40℃ to 120℃
Relay Output1 channel, 30A/30VDC, 30A/250VAC, 30A/125VAC
Output LogicNormally open and normally closed
Shell Size115mm x 90mm x 40mm
DL1-WLTE-T Gross Weight260g
DL1-WLTE-T Net Weight150g
DL1-WLTE-TVC Gross Weight270g
DL1-WLTE-TVC Net Weight160g
Table of product parameters for DL1-WLTE-T and DL1-WLTE-TVC controllers, including power, frequency, interfaces, temperature range, relay output, and dimensions.
Figure 14: Detailed Product Parameters

8. User Tips

  • For critical applications, always test the remote control functionality and alarm systems after initial setup and any configuration changes.
  • Consider placing the controller in an area with good 4G signal strength for reliable communication.
  • Regularly check the SIM card's data and call balance to ensure uninterrupted service.
  • When using the app, familiarize yourself with all settings, especially those related to temperature thresholds and timing schedules, to prevent unintended operations.

9. Warranty and Support

This product typically comes with a 1-year warranty from the date of purchase. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.