1. Introduction
The DL1-WLTE-TVC is a smart 4G LTE remote controller designed to manage various electrical equipment. It features a 30A relay output, allowing control of high-power devices via SMS, phone calls (dial control), a dedicated mobile application, or a web interface. This controller also integrates temperature monitoring and power failure alerts (TVC version only), making it suitable for a wide range of applications from home automation to industrial control.
Key Features:
- 4G LTE Connectivity: Utilizes a 4G LTE SIM card for global remote control, ignoring distance and time limitations.
- 30A Relay Output: Capable of controlling high-power equipment.
- Multiple Control Methods: Supports control via Dial, SMS, Mobile App (WLTE Control), and Web interface.
- Temperature Monitoring: Linkage with a temperature sensor to monitor real-time temperature, trigger actions, and send alarms.
- Timing Control: Schedule device operations.
- Inching/Short-time Trigger: Suitable for controlling electric gates or garage doors.
- Power Failure Alarm (TVC Version): Sends SMS/APP/Email alerts upon power failure or restoration.
- Wide Application: Ideal for home appliances, door gate openers, AC motors, remote base stations, water pumps, servers, breeding facilities, greenhouses, and more.


2. Specifications
Below are the detailed technical parameters for the DL1-WLTE-T/TVC controller:

| Parameter | Description |
|---|---|
| Model Number | DL1-WLTE-T/TVC |
| DC Power Supply | Standard adapter DC12V 1A (7-36V DC input range) |
| Power Consumption | Standby: 12V/50mA, Working Max: 12V/200mA |
| 4G Frequency (LTE-FDD) | B1/B3/B5/B7/B8/B20 |
| GSM Frequency | 900/1800mhz |
| SIM Interface | Micro SIM card |
| Antenna Interface | Standard SMA interface |
| Temperature Sensor Interface | 1 sensor port (NTC) |
| Temperature Detection Range | -40℃ to 120℃ |
| Relay Output | 1 channel, 30A/30VDC, 30A/250VAC, 30A/125VAC |
| Output Logic | Normally open and normally closed |
| Shell Size | 115mm x 90mm x 40mm |
| T Version Feature | Without power failure message alert |
| TVC Version Feature | Adds power failure message alert function |
3. Package Contents
The standard package typically includes:
- DL1-WLTE-TVC or DL1-WLTE-T Controller
- 4G Antenna
- USB Cable (for configuration/powering)
- (Optional) DC12V Power Adapter, depending on the purchased bundle.

4. Device Layout and Indicators
Familiarize yourself with the controller's ports, buttons, and indicators:

Key Components:
- COM, NO, NC (30A OUTPUT): Relay output terminals. COM is Common, NO is Normally Open, NC is Normally Closed.
- Micro SIM card slot: For inserting your 4G LTE SIM card.
- ANT: Antenna interface (SMA).
- Temp (NTC): Temperature sensor input.
- STA1, STA2: Dry contact inputs.
- SIG Indicator: Network status indicator.
- DC 7-36V Power In: Power input terminals.
- SW Button: Control switch state.
- SET Button: Used for master number setup and factory reset.
SIG Indicator Status:
- One flash per second: Device is entering the GSM network.
- One flash in two seconds: Device is connected to the 4G network. (APP control is only allowed when connected to 4G network).
- Always on: No access to the network. Check SIM card installation or antenna.
5. Setup Guide
5.1. Insert SIM Card
- Ensure the controller is powered off.
- If your Micro SIM card has a PIN code, please disable it using a mobile phone before inserting it into the controller.
- Insert the Micro SIM card into the designated slot until you hear a clicking sound.
- To remove the SIM card, push it in again until it pops out.
5.2. Power On
Connect a DC 12V power adapter to the 'Power In DC 7-36V' terminals. The device will power on automatically.
5.3. Connecting to the 4G Network
After powering on, the SIG LED will flash. Initially, it may flash once per second (GSM network). Once connected to the 4G network, it will flash once every two seconds. If the SIG LED remains constantly on, it indicates no network access. In this case, verify the SIM card installation and antenna connection. Sometimes, the issue might be with the SIM service itself.
5.4. APP Download and Initial Setup
The mobile application for controlling the device is named WLTE Control.
- For Android users: Search for "WLTE Control" on Google Play Store or use the following URL: Android App Link
- For iPhone users: Search for "WLTE Control" on the Apple App Store or use the following URL: iPhone App Link
- You can also scan the QR codes provided in the User Manual PDF for direct download.
The default password for adding devices to the app is 1234.

6. Operation
6.1. SMS Control
The controller can be operated by sending specific SMS commands. SMS control is not limited to mobile phone numbers; if the password is correct, any SMS command can enter the device.
| Function | Message Format | Controller Response | Description |
|---|---|---|---|
| Setup New Password (default pwd:0000) | SN0000NEW1234 | NEW SN SETOK, NEW SN IS 1234 | SN + password(4 numbers) + NEW + new password. |
| Setup Authorized number (up to 99 groups) | SN0000SET09#13700000000 | 09 number is 13888889999 | SN + password(4 numbers) + SET + **(Serial Number)+#Phone number (Serial Number is the position to store the authorized number, from 1-99) |
| Inquiry the Authorized number | SN0000CNK09 | 09 number is 13888889999 | SN + password(4 numbers) + CNK + **(Serial Number) |
| Remove the Authorized number | SN0000DEL09 | 09 number deleted | SN + password(4 numbers) + DEL + **(Serial Number) |
| Remove ALL Authorized numbers | SN0000DELALL | ALL numbers deleted | SN + password(4 numbers) + DEL + ALL |
| Control the relay ON by SMS command | SN0000ON | STATUS IS ALL ON, temp is:+24.7C | SN + password(4 numbers) + ON |
| Control the relay OFF by SMS command | SN0000OFF | STATUS IS ALL OFF, temp is:+24.7C | SN + password(4 numbers) + OFF |
| Setup the trigger time | SN0000L01T0001 | 01 time is 0001 seconds. | SN+password+L+01+T+length (length: 1-1000(seconds)), 001 second is default |
| Control the relay trigger by SMS command | SN0000OTGC | STATUS IS trigger. | SN + password(4 numbers) + OTG + C/X (Status: C:trigger ; X:Ignore) |
| Activate feedback SMS when input action | SN0000RLO | INPUI-LINKAGE NUMS: 1:17062167530; 2:; 3:; 4:; | SN + password(4 numbers) + RLO (*RLO is only valid after APP input control is set and push is activated) |
| Disable SMS replies when input action | SN0000RLC | INPUI-LINKAGE NUMS: 1:; 2:; 3:; 4:; | SN + password(4 numbers) + RLC |
| Enable power-off reminder SMS (TVC only) | SN0000DLO | REMINDED NUMS: 1:17062167530; 2:; 3:; 4:; | This command is only for DL1-WLTE-TVC |
| Disable power-off reminder SMS (default) | SN0000DLC | REMINDED NUMS: 1:; 2:; 3:; 4:; | This command is only for DL1-WLTE-TVC |
| Setting temperature control (Up to 8 groups) | SN0000LEA01P00256N | TAO1:LE+25.6 SW1:ON | SN + password(4 numbers) + LE/GR + A + Group number(01-08) + P/N + -) + *****(*****is the Thousands, hundreds, tens, ones and decimal + Relay code(N/F/X) |
| JOG relay via dialing (pulse relay for few seconds, then return to initial state) | SN0000TXO | JOG FUNCTION IS ON. | SN + password(4 numbers) + TXO |
| Invert relay via dialing (default) | SN0000TXC | JOG FUNCTION IS OFF. | SN + password(4 numbers) + TXC |
| Any phone can control the device | SN0000DIO | Any phone control SW1 function on | SN + password(4 numbers) + DIO |
| Only authorized number can access the device (default) | SN0000DIC | Any phone control SW1 function off | SN + password(4 numbers) + DIC |
| Check APN settings and relay status | SN0000CHECK | apn: user: pass: ; N;T:26.8C | SN + password(4 numbers) + CHECK |
| Enable dial control feedback SMS (default) | SN0000CBO | MESSAGE FUNCTION IS ON | SN + password(4 numbers) + CBO |
| Disable dial control feedback SMS | SN0000CBC | MESSAGE FUNCTION IS OFF | SN + password(4 numbers) + CBC |
| Power-off memory ON (default) (Relay status remains consistent with pre-power-off) | SN0000PAM | relay power down memory has been activated. | SN + password(4 numbers) + PAM |
| Power-off memory OFF | SN0000PAF | relay always forced to be off when power on. | SN + password(4 numbers) + PAF |

6.2. Dial Control
You can control the device by dialing its associated phone number. This method can be used for simple ON/OFF control or for triggering specific functions like the JOG relay (short-time pulse).

6.3. APP Control
The WLTE Control mobile application provides a convenient, intelligent, and user-friendly interface for managing your controller.

APP Features:
- Device Control: Directly switch the 30A relay output ON/OFF.
- Temperature Control: Monitor temperature, set thresholds, and trigger relay actions based on temperature. Receive APP notifications when temperature reaches preset values.
- Timing Control: Set up to 24 groups of timing schedules for daily or specific day operations.
- Power Failure Alarm (TVC Version): Receive APP notifications for power failure and restoration.
- APP Pushing: Get notifications to stay informed about device status.

6.4. Web Control
The controller can also be managed via a web browser on a PC, offering centralized control of your equipment.

6.5. Special Functions
6.5.1. Power Failure Alarm (DL1-WLTE-TVC only)
The TVC version of the controller provides power failure and power restoration alerts via SMS, APP, and Email. This function ensures you are immediately notified of any power interruptions.



6.5.2. Short-time Trigger Switch (Inching)
This function allows for a short-duration relay trigger (1 to 9 seconds settable), ideal for applications like opening garage doors. You can easily open your garage door with just a tap on your phone.

7. Installation
The DL1-WLTE-TVC controller supports multiple installation methods:
- DIM35mm Rail Installation: For industrial environments.
- Screw Installation: Securely mount the device using screws.

7.1. Wiring Diagrams
Refer to the following diagrams for common wiring scenarios:

8. User Tips
- Always ensure your SIM card has sufficient credit and a stable 4G signal for reliable remote control.
- For critical applications, regularly check the device status via the APP or web interface.
- When setting up temperature alerts, consider a reasonable hysteresis to prevent frequent ON/OFF cycling.
- Keep your device password secure and change it periodically.
9. Troubleshooting
9.1. Network Connection Issues (SIG LED always ON)
If the SIG LED is constantly on, it means the device cannot access the network.
- Check SIM Card: Ensure the Micro SIM card is correctly inserted and has no PIN code enabled.
- Check Antenna: Verify the 4G antenna is securely connected.
- Check SIM Service: Sometimes the problem might be with the SIM card's service itself (e.g., expired plan, no data).
- APN Settings: The device needs correct APN (Access Point Name) settings to connect to the network.
APN Configuration:
The default APN is usually 'internet' with empty user/password. If this doesn't work in your country, you need to set the correct APN via SMS.
- Check current APN: Send SMS command:
SN0000CHECK(replace 0000 with your current password). The device will reply with its current APN settings. - Set APN: Command format:
SN+password+APN+length of APN=APN content, length of user=user content, password length =password content.
Example: If APN isdatelo.com.br, useralgar, password12345, send:SN0000APN13=datelo.com.br,05=algar,05=12345. - Set APN to null: To set APN, user, and password to null, send:
SN0000APN00=00,00=0,00=0.
9.2. SMS Feedback Issues (KT Command)
If you are not receiving feedback SMS in certain situations, you might need to adjust the KT mode.
- Activate KT mode: Send SMS command:
SN+password+KT+length of country code+S+country code+L+length of number.
Example (France, country code 33, number length 9):SN0000KT2S33L09. - Deactivate KT mode: To close this mode, send:
SN0000KTC.
10. Warranty and Support
This product typically comes with a 1-year warranty from the date of purchase. For technical support, troubleshooting assistance, or warranty claims, please contact your seller or refer to the official product support channels. Always provide your product model and purchase details when seeking support.
For additional guides and documents, you may refer to the official user manual PDF: View User Manual (PDF)