The DL1-WLTE-TVC is a smart 4G LTE remote controller designed to manage various electrical equipment. It features a 30A relay output, allowing control of high-power devices via SMS, phone calls (dial control), a dedicated mobile application, or a web interface. This controller also integrates temperature monitoring and power failure alerts (TVC version only), making it suitable for a wide range of applications from home automation to industrial control.

Key Features:

  • 4G LTE Connectivity: Utilizes a 4G LTE SIM card for global remote control, ignoring distance and time limitations.
  • 30A Relay Output: Capable of controlling high-power equipment.
  • Multiple Control Methods: Supports control via Dial, SMS, Mobile App (WLTE Control), and Web interface.
  • Temperature Monitoring: Linkage with a temperature sensor to monitor real-time temperature, trigger actions, and send alarms.
  • Timing Control: Schedule device operations.
  • Inching/Short-time Trigger: Suitable for controlling electric gates or garage doors.
  • Power Failure Alarm (TVC Version): Sends SMS/APP/Email alerts upon power failure or restoration.
  • Wide Application: Ideal for home appliances, door gate openers, AC motors, remote base stations, water pumps, servers, breeding facilities, greenhouses, and more.
Remote 4G Smart Controller with key features
Remote 4G Smart Controller highlighting 30A relay, Dial/SMS, Web, APP, Temperature, and Power Failure Alert features.
Global 4G control illustration
The controller offers unlimited distance 4G global control, allowing management and alarm reception anytime, anywhere.

2. Specifications

Below are the detailed technical parameters for the DL1-WLTE-T/TVC controller:

Product parameter table
Detailed product parameters for the DL1-WLTE-T/TVC controller.
DL1-WLTE-T/TVC Controller Specifications
ParameterDescription
Model NumberDL1-WLTE-T/TVC
DC Power SupplyStandard adapter DC12V 1A (7-36V DC input range)
Power ConsumptionStandby: 12V/50mA, Working Max: 12V/200mA
4G Frequency (LTE-FDD)B1/B3/B5/B7/B8/B20
GSM Frequency900/1800mhz
SIM InterfaceMicro SIM card
Antenna InterfaceStandard SMA interface
Temperature Sensor Interface1 sensor port (NTC)
Temperature Detection Range-40℃ to 120℃
Relay Output1 channel, 30A/30VDC, 30A/250VAC, 30A/125VAC
Output LogicNormally open and normally closed
Shell Size115mm x 90mm x 40mm
T Version FeatureWithout power failure message alert
TVC Version FeatureAdds power failure message alert function

3. Package Contents

The standard package typically includes:

  • DL1-WLTE-TVC or DL1-WLTE-T Controller
  • 4G Antenna
  • USB Cable (for configuration/powering)
  • (Optional) DC12V Power Adapter, depending on the purchased bundle.
DL1-WLTE-T version with antenna and USB cable
DL1-WLTE-T version shown with included antenna and USB cable. Note: T version does not have power failure alarm.

4. Device Layout and Indicators

Familiarize yourself with the controller's ports, buttons, and indicators:

DL1-WLTE-TVC controller overview with labels
Overview of the DL1-WLTE-TVC controller showing ports and indicators.

Key Components:

  • COM, NO, NC (30A OUTPUT): Relay output terminals. COM is Common, NO is Normally Open, NC is Normally Closed.
  • Micro SIM card slot: For inserting your 4G LTE SIM card.
  • ANT: Antenna interface (SMA).
  • Temp (NTC): Temperature sensor input.
  • STA1, STA2: Dry contact inputs.
  • SIG Indicator: Network status indicator.
  • DC 7-36V Power In: Power input terminals.
  • SW Button: Control switch state.
  • SET Button: Used for master number setup and factory reset.

SIG Indicator Status:

  • One flash per second: Device is entering the GSM network.
  • One flash in two seconds: Device is connected to the 4G network. (APP control is only allowed when connected to 4G network).
  • Always on: No access to the network. Check SIM card installation or antenna.

5. Setup Guide

5.1. Insert SIM Card

  1. Ensure the controller is powered off.
  2. If your Micro SIM card has a PIN code, please disable it using a mobile phone before inserting it into the controller.
  3. Insert the Micro SIM card into the designated slot until you hear a clicking sound.
  4. To remove the SIM card, push it in again until it pops out.

5.2. Power On

Connect a DC 12V power adapter to the 'Power In DC 7-36V' terminals. The device will power on automatically.

5.3. Connecting to the 4G Network

After powering on, the SIG LED will flash. Initially, it may flash once per second (GSM network). Once connected to the 4G network, it will flash once every two seconds. If the SIG LED remains constantly on, it indicates no network access. In this case, verify the SIM card installation and antenna connection. Sometimes, the issue might be with the SIM service itself.

5.4. APP Download and Initial Setup

The mobile application for controlling the device is named WLTE Control.

  • For Android users: Search for "WLTE Control" on Google Play Store or use the following URL: Android App Link
  • For iPhone users: Search for "WLTE Control" on the Apple App Store or use the following URL: iPhone App Link
  • You can also scan the QR codes provided in the User Manual PDF for direct download.

The default password for adding devices to the app is 1234.

APP instruction screens for device management
Screenshots illustrating the WLTE Control APP interface and device management.

6. Operation

6.1. SMS Control

The controller can be operated by sending specific SMS commands. SMS control is not limited to mobile phone numbers; if the password is correct, any SMS command can enter the device.

SMS Commands and Description
FunctionMessage FormatController ResponseDescription
Setup New Password (default pwd:0000)SN0000NEW1234NEW SN SETOK, NEW SN IS 1234SN + password(4 numbers) + NEW + new password.
Setup Authorized number (up to 99 groups)SN0000SET09#1370000000009 number is 13888889999SN + password(4 numbers) + SET + **(Serial Number)+#Phone number (Serial Number is the position to store the authorized number, from 1-99)
Inquiry the Authorized numberSN0000CNK0909 number is 13888889999SN + password(4 numbers) + CNK + **(Serial Number)
Remove the Authorized numberSN0000DEL0909 number deletedSN + password(4 numbers) + DEL + **(Serial Number)
Remove ALL Authorized numbersSN0000DELALLALL numbers deletedSN + password(4 numbers) + DEL + ALL
Control the relay ON by SMS commandSN0000ONSTATUS IS ALL ON, temp is:+24.7CSN + password(4 numbers) + ON
Control the relay OFF by SMS commandSN0000OFFSTATUS IS ALL OFF, temp is:+24.7CSN + password(4 numbers) + OFF
Setup the trigger timeSN0000L01T000101 time is 0001 seconds.SN+password+L+01+T+length (length: 1-1000(seconds)), 001 second is default
Control the relay trigger by SMS commandSN0000OTGCSTATUS IS trigger.SN + password(4 numbers) + OTG + C/X (Status: C:trigger ; X:Ignore)
Activate feedback SMS when input actionSN0000RLOINPUI-LINKAGE NUMS: 1:17062167530; 2:; 3:; 4:;SN + password(4 numbers) + RLO (*RLO is only valid after APP input control is set and push is activated)
Disable SMS replies when input actionSN0000RLCINPUI-LINKAGE NUMS: 1:; 2:; 3:; 4:;SN + password(4 numbers) + RLC
Enable power-off reminder SMS (TVC only)SN0000DLOREMINDED NUMS: 1:17062167530; 2:; 3:; 4:;This command is only for DL1-WLTE-TVC
Disable power-off reminder SMS (default)SN0000DLCREMINDED NUMS: 1:; 2:; 3:; 4:;This command is only for DL1-WLTE-TVC
Setting temperature control (Up to 8 groups)SN0000LEA01P00256NTAO1:LE+25.6 SW1:ONSN + password(4 numbers) + LE/GR + A + Group number(01-08) + P/N + -) + *****(*****is the Thousands, hundreds, tens, ones and decimal + Relay code(N/F/X)
JOG relay via dialing (pulse relay for few seconds, then return to initial state)SN0000TXOJOG FUNCTION IS ON.SN + password(4 numbers) + TXO
Invert relay via dialing (default)SN0000TXCJOG FUNCTION IS OFF.SN + password(4 numbers) + TXC
Any phone can control the deviceSN0000DIOAny phone control SW1 function onSN + password(4 numbers) + DIO
Only authorized number can access the device (default)SN0000DICAny phone control SW1 function offSN + password(4 numbers) + DIC
Check APN settings and relay statusSN0000CHECKapn: user: pass: ; N;T:26.8CSN + password(4 numbers) + CHECK
Enable dial control feedback SMS (default)SN0000CBOMESSAGE FUNCTION IS ONSN + password(4 numbers) + CBO
Disable dial control feedback SMSSN0000CBCMESSAGE FUNCTION IS OFFSN + password(4 numbers) + CBC
Power-off memory ON (default) (Relay status remains consistent with pre-power-off)SN0000PAMrelay power down memory has been activated.SN + password(4 numbers) + PAM
Power-off memory OFFSN0000PAFrelay always forced to be off when power on.SN + password(4 numbers) + PAF
SMS control examples
Examples of devices controlled via SMS, including electric heater, water pump, Ethernet switch, and charging pile.

6.2. Dial Control

You can control the device by dialing its associated phone number. This method can be used for simple ON/OFF control or for triggering specific functions like the JOG relay (short-time pulse).

Dial control examples
Illustrates controlling devices like electric heaters, water heaters, electric fans, and electric doors by dialing.

6.3. APP Control

The WLTE Control mobile application provides a convenient, intelligent, and user-friendly interface for managing your controller.

APP control interface examples
Various screens of the WLTE Control APP, showing login, device control, and timing settings.

APP Features:

  • Device Control: Directly switch the 30A relay output ON/OFF.
  • Temperature Control: Monitor temperature, set thresholds, and trigger relay actions based on temperature. Receive APP notifications when temperature reaches preset values.
  • Timing Control: Set up to 24 groups of timing schedules for daily or specific day operations.
  • Power Failure Alarm (TVC Version): Receive APP notifications for power failure and restoration.
  • APP Pushing: Get notifications to stay informed about device status.
APP features: 30A relay, temperature control, timing control
Detailed view of APP features including 30A relay output, temperature control, and timing control.

6.4. Web Control

The controller can also be managed via a web browser on a PC, offering centralized control of your equipment.

Web control interface
Screenshot of the web control interface for centralized management.

6.5. Special Functions

6.5.1. Power Failure Alarm (DL1-WLTE-TVC only)

The TVC version of the controller provides power failure and power restoration alerts via SMS, APP, and Email. This function ensures you are immediately notified of any power interruptions.

Power failure alarm function (TVC version only)
Illustrates the power failure alarm function, available only on the TVC version, showing alerts on a smartphone.
E-Mail pushing function
The E-Mail pushing function sends notifications when the temperature reaches a preset value.
APP pushing notifications
APP pushing notifications ensure you don't miss important device status updates, including power and temperature alerts.

6.5.2. Short-time Trigger Switch (Inching)

This function allows for a short-duration relay trigger (1 to 9 seconds settable), ideal for applications like opening garage doors. You can easily open your garage door with just a tap on your phone.

Short-time trigger switch for garage doors
Demonstration of the short-time trigger switch function for opening a garage door via smartphone.

7. Installation

The DL1-WLTE-TVC controller supports multiple installation methods:

  • DIM35mm Rail Installation: For industrial environments.
  • Screw Installation: Securely mount the device using screws.
Installation methods: DIM35mm, industrial rail, screw
Illustrates DIM35mm rail and screw installation methods for the controller, including dimensions.

7.1. Wiring Diagrams

Refer to the following diagrams for common wiring scenarios:

Wiring diagrams for various applications
Wiring examples for low power lamps, DC motors, high-power AC motors (with contactor), and electronic lock triggers.

8. User Tips

  • Always ensure your SIM card has sufficient credit and a stable 4G signal for reliable remote control.
  • For critical applications, regularly check the device status via the APP or web interface.
  • When setting up temperature alerts, consider a reasonable hysteresis to prevent frequent ON/OFF cycling.
  • Keep your device password secure and change it periodically.

9. Troubleshooting

9.1. Network Connection Issues (SIG LED always ON)

If the SIG LED is constantly on, it means the device cannot access the network.

  • Check SIM Card: Ensure the Micro SIM card is correctly inserted and has no PIN code enabled.
  • Check Antenna: Verify the 4G antenna is securely connected.
  • Check SIM Service: Sometimes the problem might be with the SIM card's service itself (e.g., expired plan, no data).
  • APN Settings: The device needs correct APN (Access Point Name) settings to connect to the network.

APN Configuration:

The default APN is usually 'internet' with empty user/password. If this doesn't work in your country, you need to set the correct APN via SMS.

  • Check current APN: Send SMS command: SN0000CHECK (replace 0000 with your current password). The device will reply with its current APN settings.
  • Set APN: Command format: SN+password+APN+length of APN=APN content, length of user=user content, password length =password content.
    Example: If APN is datelo.com.br, user algar, password 12345, send: SN0000APN13=datelo.com.br,05=algar,05=12345.
  • Set APN to null: To set APN, user, and password to null, send: SN0000APN00=00,00=0,00=0.

9.2. SMS Feedback Issues (KT Command)

If you are not receiving feedback SMS in certain situations, you might need to adjust the KT mode.

  • Activate KT mode: Send SMS command: SN+password+KT+length of country code+S+country code+L+length of number.
    Example (France, country code 33, number length 9): SN0000KT2S33L09.
  • Deactivate KT mode: To close this mode, send: SN0000KTC.

10. Warranty and Support

This product typically comes with a 1-year warranty from the date of purchase. For technical support, troubleshooting assistance, or warranty claims, please contact your seller or refer to the official product support channels. Always provide your product model and purchase details when seeking support.

For additional guides and documents, you may refer to the official user manual PDF: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.