1. Introduction
This manual provides essential information for the safe and effective operation of your Hantek 4-Channel Digital Oscilloscope. Please read this manual thoroughly before using the device and keep it for future reference.
The Hantek DSO4084B, DSO4104B, DSO4204B, and DSO4254B series are advanced 4-channel digital oscilloscopes designed for precise signal analysis. They feature a high sample rate, wide bandwidth, and various measurement functions to meet diverse testing requirements.


2. Safety Information
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.
- Do not remove the cover unless by specified personnel. Hazardous voltage is present inside.
- Ensure the power supply voltage is within the specified range (100-240VACRMS, 45-440Hz).
- Use only the power cord and accessories specified for this instrument.
- Do not operate the instrument in wet or damp conditions.
- Do not operate the instrument in explosive atmospheres.
- Keep the instrument clean and dry.
- Refer all servicing to qualified service personnel.
3. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.

- 1 x Hantek Digital Storage Oscilloscope
- 4 x Oscilloscope Probes
- 1 x USB Cable
- 1 x Power Cable
- 1 x CD (containing software and documentation)
4. Setup and Connection
- **Power Connection:** Connect the provided power cable to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the voltage matches the instrument's requirements (100-240VACRMS).
- **Probe Connection:** Connect the oscilloscope probes to the BNC input connectors (CH1, CH2, CH3, CH4) on the front panel. Ensure a secure connection.
- **Grounding:** Always ensure the oscilloscope is properly grounded through the power cord's ground conductor.
- **External Trigger (Optional):** If using an external trigger, connect the signal source to the "Ext Trig" input.
- **USB Connection (Optional):** For PC communication or firmware updates, connect the USB cable from the oscilloscope's USB port to your computer.
- **Initial Power On:** Press the power button on the front panel to turn on the oscilloscope.
5. Basic Operation
The Hantek Digital Oscilloscope features a user-friendly interface with dedicated controls for vertical, horizontal, and trigger settings.

5.1 Vertical Controls
- **VOLTS/DIV Knobs:** Adjust the vertical scale (voltage per division) for each channel.
- **Position Knobs:** Adjust the vertical position of the waveform for each channel.
- **CH1-CH4 Buttons:** Enable or disable individual channels.
5.2 Horizontal Controls
- **SEC/DIV Knob:** Adjust the horizontal time base (time per division).
- **Position Knob:** Adjust the horizontal position of the waveform.
5.3 Trigger Controls
- **Trigger Level Knob:** Sets the voltage level at which the trigger event occurs.
- **Mode Button:** Select trigger mode (Auto, Normal, Single).
- **Type Button:** Select trigger type (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC).
- **Source Button:** Select the trigger source (CH1, CH2, CH3, CH4, EXT).
5.4 Automatic Measurements
The oscilloscope supports over 32 types of automatic measurements. Use the dedicated measurement menu to select and display parameters such as Frequency, Period, Average, Pk-Pk, RMS, RiseTime, FallTime, etc.
5.5 Data Storage and Connectivity
- **USB Host/Device:** Use the USB port for connecting to a PC for data transfer or for system updates via a U-stick.
- **Optional Connectivity:** Depending on your model, optional RS232, LAN, HDMI, touch screen, WIFI, and SD card storage may be available for enhanced connectivity and data management.
Video 1: Product demonstration showing basic operation and features.
6. Maintenance
6.1 General Care
- **Cleaning:** Clean the instrument regularly with a soft, dry cloth. For stubborn dirt, use a cloth lightly dampened with water or a mild detergent. Do not use abrasive cleaners or solvents.
- **Storage:** Store the oscilloscope in a clean, dry environment away from direct sunlight and extreme temperatures.
- **Ventilation:** Ensure proper ventilation around the instrument to prevent overheating. Do not block the ventilation openings.
6.2 Firmware Updates
Periodically check the manufacturer's website for firmware updates. Updates can improve performance, add new features, or fix bugs. Follow the instructions provided with the firmware update package carefully, typically involving a USB U-stick.
6.3 Calibration
For optimal accuracy, periodic calibration by qualified personnel is recommended. Refer to the included "Certificate of Calibration" for details on recommended calibration intervals.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power | Power cable not connected, power outlet faulty, fuse blown. | Check power cable connection. Test power outlet. Check and replace fuse if necessary (refer to safety guidelines). |
| No waveform displayed | Probe not connected, channel disabled, vertical/horizontal scale incorrect, trigger not set correctly. | Ensure probes are connected. Enable the desired channel. Adjust VOLTS/DIV and SEC/DIV. Check trigger settings (level, source, mode). |
| Unstable waveform | Trigger level too high/low, incorrect trigger source, noisy signal. | Adjust trigger level. Select appropriate trigger source. Use averaging acquisition mode for noisy signals. |
| USB connection issues | Incorrect USB cable, driver not installed, software issues. | Use the provided USB cable. Install necessary drivers from the included CD or manufacturer's website. Restart both oscilloscope and PC. |
8. Specifications
| Feature | DSO4254B | DSO4204B | DSO4104B | DSO4084B |
|---|---|---|---|---|
| Bandwidth | 250MHz | 200MHz | 100MHz | 80MHz |
| Sample Rate Range | 1GS/s | |||
| Record Length | Max 64K samples (single-channel), Max 32K samples (dual-channel) | |||
| SEC/DIV Range | 2ns/div ~ 100s/div | |||
| AD Converter | 8-bit resolution, each channel sampled simultaneously | |||
| VOLTS/DIV Range | 500μV/div to 10V/div | |||
| Rise Time (typical) | <1.4ns | ≤1.8ns | <3.5ns ≤4.4ns | |
| DC Gain Accuracy | ±3% (Normal/Average, 10V/div to 10mV/div); ±4% (Normal/Average, 5mV/div to 500μV/div) | |||
| Display Type | 7 inch 64K color TFT | |||
| Display Resolution | 800 x 480 pixels | |||
| Power Supply | 100-240VACRMS (±10%), 45Hz to 440Hz | |||
| Power Consumption | <30W | |||
| Dimensions (L x W x H) | 318 x 110 x 150mm | |||
| Weight | 2900g | |||
Note: Bandwidth reduced to 6MHz when using a 1X probe.
9. User Tips
- For accurate measurements, always ensure your probes are properly compensated.
- When dealing with noisy signals, utilize the 'Average' acquisition mode to get a clearer waveform.
- Experiment with different trigger types and sources to capture specific events effectively.
- Keep the included CD or download the latest software and drivers from the Hantek website for optimal performance and compatibility.
10. Warranty and Support
Hantek products are designed for reliability and performance. We offer after-sell service within 1 year of purchase. In case of missing or defective parts, please notify us no later than 5 days after you receive the item, and we will arrange re-shipment.
For warranty information and technical support, please refer to the official Hantek website or contact your local distributor.
In case of any issues, please provide your product model number and serial number when contacting support.
Manufacturer: Hantek
Contact Information: Refer to the official Hantek website for the most up-to-date support and contact details.