1. Introduction

Thank you for choosing the Jebao TM Series Submersible Pump. This pump is designed for efficient and quiet water circulation in various aquatic environments, including marine and freshwater aquariums, fish tanks, ponds, and fountains. Its high-performance motor and durable components ensure a long operational life and energy efficiency. Please read this manual thoroughly before installation and operation to ensure proper use and maintenance.

2. Safety Instructions

  • Always disconnect the power supply before performing any maintenance, installation, or handling of the pump.
  • Ensure the pump is fully submerged in water during operation to prevent overheating and damage.
  • Do not operate the pump if the power cord or plug is damaged.
  • This pump is designed for 220-240V/50Hz electrical systems. Ensure your power supply matches these requirements.
  • Keep the pump away from children and pets.
  • Do not use the pump for purposes other than those specified in this manual.
  • The pump is suitable for water temperatures up to 35°C.

3. Package Contents

Upon unpacking, please verify that all the following items are included:

  • 1 x Jebao TM Series Submersible Pump
  • Assorted Outlet Adapters (20mm, 25mm, 30mm/32mm)
  • Sealing Rings
  • 1 x Power Cord with appropriate plug adapter (EU/US/UK/AU, configured for your region)
Jebao TM Series Submersible Pump with various outlet adapters and sealing rings.
Figure 1: Jebao TM Series Submersible Pump with various outlet adapters and sealing rings.
Exploded view of the Jebao TM Series pump components, including the pump body, grille, power cord, and various adapters.
Figure 2: Exploded view of the Jebao TM Series pump components, including the pump body, grille, power cord, and various adapters.

4. Features

  • High Performance Motor: Equipped with innovative electronics for powerful and reliable operation.
  • Energy Saving: Achieves energy savings of up to 65%.
  • Super Quiet Operation: Designed for minimal noise output.
  • IC Electronic Detection: Features automatic power-off protection if the water level is too low (no water).
  • Motor Protection: Includes protection mechanisms if the rotor becomes blocked.
  • Versatile Use: Suitable for both marine (saltwater) and freshwater environments.
  • No Copper Element: Ensures safety for sensitive aquatic life.
  • Durable Construction: Features a wear-resistant ceramic shaft for extended operational life.
  • Amphibious Design: Can be used submerged or externally (sitting fixed form).
Jebao TM Series pump highlighting key features: Electronic frequency conversion, Super corrosion resistant, Ceramic bearing, Super silent.
Figure 3: Key features of the Jebao TM Series pump.

5. Specifications

The Jebao TM Series pumps are available in several models, each with specific performance characteristics:

ModelPowerMax Head (H. max)Max FlowSize (L*W*H)Suitable Tank Size
TM-350025W (30W in some listings)3.5M3500L/h27*8*11cm (or 20*10*14cm)90-120cm (or 600-700L)
TM-500040W3.5M5000L/h20*10*14cm120-150cm (or 700-1000L)
TM-650050W4.0M6500L/h20*10*14cm130-180cm (or 1000-1300L)
TM-800065W4.5M8000L/h20*10*14cm150-200cm (or 1300-1600L)
TM-1000075W5.0M10000L/h20*10*14cm200-250cm (or 1600-2000L)

General Specifications:

  • Voltage: 220-240V/50Hz
  • Outlet & Inlet Diameter: 20mm, 25mm, 30mm (or 32mm)
  • Material: Rubber
  • Fixed Form: Sitting
  • Power Source: Charge (wired)
  • Battery Included: No
  • High-concerned chemical: None
  • Origin: Mainland China
  • Plug Adapters: US, AU, UK, EU (provided based on region)
  • Max. Temperature: 35°C
  • Protection Rating: IPX8
Jebao TM-3500 pump with detailed specifications: Power 30W, Flow 3500L/h, Head 3.5m, Size 200x100x140mm, Suitable for 600-700L tank, and outlet diameters (32mm, 25mm, 20mm).
Figure 4: Specifications for Jebao TM-3500 pump.
Jebao TM-5000 pump with detailed specifications: Power 40W, Flow 5000L/h, Head 3.5m, Size 200x100x140mm, Suitable for 700-1000L tank, and outlet diameters (32mm, 25mm, 20mm).
Figure 5: Specifications for Jebao TM-5000 pump.
Jebao TM-6500 pump with detailed specifications: Power 50W, Flow 6500L/h, Head 4.0m, Size 200x100x140mm, Suitable for 1000-1300L tank, and outlet diameters (32mm, 25mm, 20mm).
Figure 6: Specifications for Jebao TM-6500 pump.
Jebao TM-8000 pump with detailed specifications: Power 65W, Flow 8000L/h, Head 4.5m, Size 200x100x140mm, Suitable for 1300-1600L tank, and outlet diameters (32mm, 25mm, 20mm).
Figure 7: Specifications for Jebao TM-8000 pump.
Jebao TM-10000 pump with detailed specifications: Power 75W, Flow 10000L/h, Head 5.0m, Size 200x100x140mm, Suitable for 1600-2000L tank, and outlet diameters (32mm, 25mm, 20mm).
Figure 8: Specifications for Jebao TM-10000 pump.
Close-up of a Jebao TM-6500 pump label showing model, voltage, power, frequency, max temperature, CE certification, and IPX8 rating.
Figure 9: Example pump label with technical details.

6. Installation and Setup

The Jebao TM Series pump can be used either fully submerged or externally (amphibious setup).

6.1. Connecting Outlet Adapters

  1. Select the appropriate outlet adapter (20mm, 25mm, or 30mm/32mm) for your tubing.
  2. Attach the chosen adapter securely to the pump's outlet port. Ensure a tight fit to prevent leaks.
  3. If using, connect your desired tubing to the adapter.
Jebao TM Series pump with a single outlet adapter, ready for connection.
Figure 10: Pump with a single outlet adapter attached.
Jebao TM Series pump with a single outlet adapter attached, showing the compact design.
Figure 11: Compact design with an attached outlet adapter.

6.2. Submersible Installation

  • Place the pump at the desired location within your aquarium, pond, or fountain. Ensure it rests on a stable, flat surface. The pump is designed with a 'sitting' fixed form.
  • Ensure the pump is fully submerged in water before connecting to power.

6.3. External (Amphibious) Installation

  • Position the pump on a stable surface outside the water body.
  • Connect appropriate inlet and outlet tubing to the pump. Ensure all connections are watertight.
  • Prime the pump by ensuring water flows into the inlet before powering on, if necessary, to prevent dry running.
Top and side view of the Jebao TM Series pump, illustrating the water inlet and outlet connections.
Figure 12: Water inlet and outlet connections for amphibious setup.

6.4. Power Connection

  • Connect the pump's power cord to a suitable electrical outlet (220-240V/50Hz).
  • The product includes a plug adapter (EU/US/UK/AU) suitable for your local socket.

7. Operation

  • Once installed and connected to power, the pump will begin operating.
  • The pump features IC electronic detection for automatic power-off protection if it detects no water, preventing dry running damage.
  • In case of a blocked rotor, the motor protection system will activate to prevent damage.
  • The pump is designed for super quiet operation, minimizing disturbance to your aquatic environment.

8. Maintenance

Regular maintenance ensures optimal performance and extends the life of your pump.

  • Disconnect Power: Always unplug the pump from the power source before any maintenance.
  • Clean Impeller and Housing: Periodically remove the pump from the water and disassemble the front grille to access the impeller. Clean any debris, algae, or mineral buildup from the impeller and its housing using a soft brush and clean water.
  • Inspect Ceramic Shaft: Check the wear-resistant ceramic shaft for any signs of damage or excessive wear. Replace if necessary.
  • Check Connections: Ensure all hose connections and adapters are secure and free from leaks.
  • Rinse Thoroughly: After cleaning, rinse all components with clean water before reassembling and returning the pump to operation.

9. Troubleshooting

ProblemPossible CauseSolution
Pump does not start or run.No power; Impeller blocked; Dry running protection activated.Check power connection; Clean impeller; Ensure pump is fully submerged.
Reduced water flow.Inlet/outlet blocked; Impeller dirty; Kinked tubing.Clean inlet/outlet and impeller; Straighten tubing.
Excessive noise.Debris in impeller; Pump not stable; Air in pump (for external use).Clean impeller; Ensure stable placement; Re-prime pump if external.
Pump stops intermittently.Overheating; Dry running; Rotor blocked.Ensure proper submersion/cooling; Clean impeller/rotor.

10. User Tips

  • For optimal performance and longevity, perform routine cleaning of the pump and impeller every 2-4 weeks, depending on water conditions.
  • When using the pump externally, ensure the inlet hose is always submerged and free of air to prevent dry running and potential damage.
  • Always use the correct size tubing for the chosen outlet adapter to maximize flow efficiency and prevent strain on the pump.
  • Consider placing the pump on a vibration-dampening mat if minor noise is still an issue in sensitive environments.

11. Warranty and Support

For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Related Documents - TM-3500, TM-5000, TM-6500, TM-8000, TM-10000

Preview Jebao DC Pump Owner's Manual - Models DCP-2500 to DCP-20000
The Jebao DC Pump Owner's Manual provides comprehensive instructions for the safe operation, installation, maintenance, and troubleshooting of DCP-2500, DCP-3000, DCP-4000, DCP-5000, DCP-6500, DCP-8000, DCP-10000, DCP-15000, DCP-18000, and DCP-20000 models. Learn about features like adjustable flow rate, feed mode, memory function, and automatic power-off protection for both submersible and non-submersible applications in marine and fresh water environments.
Preview Jebao DC Pump User Manual - DCP Series
Comprehensive user manual for Jebao DC Pumps (DCP-2500 to DCP-20000), covering features, operation, maintenance, and troubleshooting.
Preview Jebao MDC Series Aquarium Pumps User Manual
User manual for Jebao MDC series aquarium pumps, detailing features, safety instructions, installation, operation, and technical specifications. Includes models MDC-2000 to MDC-10000.
Preview Jebao Smart DC Pump User Manual - MDP Series
Comprehensive user manual for Jebao Smart DC Pumps (MDP Series), covering features, operation, app control, Wi-Fi setup, maintenance, and troubleshooting.
Preview Jebao DC Pump Owner's Manual - DCW Series
Comprehensive owner's manual for Jebao DC Pumps, covering models DCW-2000 to DCW-10000. Details features, operating instructions, controller functions, maintenance, troubleshooting, and disposal guidelines.
Preview Jebao Submersible Pump Owner's Manual
Owner's manual for Jebao submersible pumps, models PP-355 and PP-377. Provides instructions on operation, safety warnings, and maintenance.