SUSWE SU900 Series Variable Frequency Drive User Manual

Model: SU900-22R0G3 | Brand: SUSWE

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SUSWE SU900 Series Variable Frequency Drive (VFD). The SU900 series is designed for precise control of three-phase AC motors, commonly used in applications such as water pumps, fans, and other industrial machinery. Please read this manual thoroughly before attempting any installation or operation.

2. Safety Information

WARNING: Dangerous voltages are present inside the VFD. Only qualified personnel should perform installation, wiring, and maintenance. Disconnect all power sources and wait at least 5 minutes for capacitors to discharge before touching any components.

  • Ensure proper grounding of the VFD and the motor.
  • Do not operate the VFD with damaged cables or loose connections.
  • Protect the VFD from moisture, dust, and direct sunlight.
  • Always wear appropriate personal protective equipment (PPE) when working with electrical equipment.
  • Refer to local electrical codes and regulations for installation requirements.

3. Product Overview

The SUSWE SU900 Series VFD offers V/F vector control for stable and efficient motor operation. It features a user-friendly control panel for easy parameter setting and monitoring.

3.1. Product Views

SUSWE SU900 VFD front view
Front view of the SUSWE SU900 Variable Frequency Drive.
Detailed front view of the SU900 VFD
Detailed front view highlighting the display and control buttons.
Side view of the SU900 VFD
Side view of the VFD, showing ventilation and mounting points.
Rear view of the SU900 VFD
Rear view of the VFD, showing power input and output terminals.

3.2. Control Panel

Close-up of the control panel with labeled buttons and display
Close-up of the VFD control panel, indicating display and button functions.

The control panel features a digital display and several buttons for operation and parameter adjustment:

  • Display Screen: Shows frequency, current, voltage, and other operational parameters.
  • Knob: Used for adjusting frequency or parameter values.
  • RUN Key: Starts the motor.
  • STOP Key: Stops the motor.
  • PRG Key: Enters/exits programming mode.
  • Arrow Keys (Up/Down/Left/Right): Navigate menus and adjust values.
  • MFK Key: Multi-function key, context-dependent.
  • ENTER Key: Confirms selections or parameter changes.

3.3. Detachable Operation Panel

Detachable control panel and connection ports
The VFD features a detachable control panel for remote operation and control.

The operation panel can be detached from the main unit for remote control. To remove, press inward on the side clips and gently pull the panel away. Connect it to the main unit using a standard Ethernet cable (RJ45) for remote operation.

4. Specifications

4.1. General Specifications

AttributeValue
Product NameFrequency Inverter VFD
Brand NameSUSWE
Model NumberSU900-22R0G3 (Specific model)
TypeAC-DC-AC
Control ModeV/F vector control
Nominal Voltage380 V
Power Phase NumberThree Phase
Rated Power22KW
SizeDepending on the model
CustomizedYes
Place of OriginJiangsu, China
DIY SuppliesElectrical

4.2. Model Naming Rules

Naming rules for SU800/900 series VFDs
Diagram explaining the naming convention for SU800/900 series frequency converters.

The model number follows a specific format: SU800/900 - Power Grade - Voltage Grade

  • Voltage Grade:
    • G1: Input single-phase 220V, Output three-phase 220V
    • G2: Input single-phase 220V, Output three-phase 380V
    • G3: Input single-phase 380V, Output three-phase 380V
  • Power Grade:
    • 0R75: 0.75KW
    • 1R5: 1.5KW
    • 2R2: 2.2KW
    • ...and so on, where 'R' denotes a decimal point.

4.3. SU800/900 Series Index (Three Phase Power Supply: 380V, 50Hz/60Hz)

Table of SU800/900 series VFD specifications for three-phase 380V input
Detailed specifications for SU800/900 series frequency converters with three-phase 380V input.
Frequency Converter ModePower Supply Capacity (KVA)Rated Input Current (A)Rated Output Current (A)Adapted Motor (kW)Adapted Motor (HP)
SU800-0R75G31.53.62.50.751
SU800-1R5G335.14.11.52
SU800-2R2G3465.82.23
SU800-4R0G36.110.5945
SU800-5R5G38.914135.57.5
SU800-7R5G31121177.510
SU900-0R75G31.53.62.50.751
SU900-1R5G335.14.11.52
SU900-2R2G3465.82.23
SU900-4R0G36.110.5945
SU900-5R5G38.914.6135.57.5
SU900-7R5G31121177.510
SU900-11R0G31726251115
SU900-15R0G32135321520
SU900-18R5G32438.53718.525
SU900-22R0G33046.5452230
SU900-30R0G34062603040
SU900-37R0G35776753750
SU900-45R0G36992914560

5. Setup and Installation

5.1. Mounting

Mount the VFD in a vertical position on a flat, non-flammable surface. Ensure adequate clearance around the unit for proper ventilation and heat dissipation. Avoid mounting in direct sunlight or areas with excessive dust or moisture.

5.2. Wiring

CAUTION: All wiring must be performed by a qualified electrician. Ensure power is disconnected before making any connections.

Terminal wiring diagram for the frequency converter control circuit
Fig 2-2: Wiring method of frequency converter control circuit.

Refer to the wiring diagram (Fig 2-2) for detailed connection instructions. Key connections include:

  • Input Power (R, S, T / L, N): Connect the three-phase 380V AC power supply to the input terminals. Ensure correct phase sequence.
  • Ground (PE): Connect the ground wire to the designated ground terminal. This is crucial for safety.
  • Motor Output (U, V, W): Connect the three-phase motor to these output terminals.
  • Braking Resistance (P+, PB): If a braking resistor is used, connect it to these terminals.
  • Control Terminals (X1-X4, HDI, AI1, AI2, AO1, Y1, K1A/B/C, RS485): These terminals are for external control signals, analog inputs/outputs, relay outputs, and RS485 communication. Consult the full product manual for detailed functions and programming of these terminals.
  • DC24V Power Supply: Provides 24V DC for control circuits.

6. Operating Instructions

6.1. Basic Operation

  1. Power On: After ensuring all wiring is correct and secure, apply power to the VFD. The display will light up.
  2. Start Motor: Press the RUN button on the control panel. The motor will start and accelerate to the set frequency.
  3. Adjust Frequency: Use the knob on the control panel to adjust the output frequency, thereby controlling the motor speed. The display will show the current frequency (Hz) and other parameters.
  4. Stop Motor: Press the STOP button. The motor will decelerate and stop.

6.2. Operation Demonstration Video

Watch this video for a visual demonstration of the VFD's basic operation and motor control:

Video demonstrating the connection and operation of the SUSWE VFD with a three-phase motor, showing speed adjustment.

6.3. Parameter Setting

To access and modify VFD parameters, press the PRG button. Use the arrow keys to navigate through menus and the knob to change values. Press ENTER to confirm changes. Refer to the comprehensive programming manual (not included here) for a full list of parameters and their functions.

7. Maintenance

WARNING: Disconnect all power before performing any maintenance.

  • Regular Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ventilation: Ensure that the ventilation openings are not blocked to prevent overheating. Periodically clean the cooling fan and heatsink fins.
  • Connection Check: Periodically inspect all wiring connections for tightness and signs of corrosion or damage.
  • Environmental Conditions: Ensure the VFD operates within its specified environmental conditions (temperature, humidity).

8. Troubleshooting

If the VFD is not functioning correctly, consider the following basic troubleshooting steps:

  • No Power/Display: Check the input power supply and circuit breaker. Ensure all power connections are secure.
  • Motor Not Running: Verify the RUN command is active. Check motor wiring and ensure the motor is not overloaded or jammed. Check for any fault codes on the display.
  • Overcurrent/Overvoltage Fault: This could indicate an issue with the motor, load, or power supply. Reduce the load, check motor parameters, or consult a specialist.
  • Overheating: Ensure proper ventilation and ambient temperature. Clean any dust from the heatsink and fan.

For specific fault codes and advanced troubleshooting, refer to the detailed technical manual or contact customer support.

9. Warranty and Support

The SUSWE SU900 Series Variable Frequency Drive comes with a warranty period of 3 months to 1 year, depending on the specific product and terms of purchase. For any quality problems or technical assistance, please contact SUSWE customer support. Our team is committed to providing satisfactory service and will assist you in resolving any issues.

You can reach customer staff via WHATSAPP: +8617267881780 or Email: 522646865@qq.com.

10. User Tips

No specific user tips were available from reviews or Q&A for this product at this time. Always ensure your VFD is correctly sized for your motor and application to achieve optimal performance and longevity.

11. Company Information

Suzhou Sute Electronic Technology Co., Ltd. is an electronic product manufacturer integrating R&D, production, sales, and service. Established in 2019 and located in Kunshan, Suzhou, China, the company has invested significantly in its production base and employs over 100 people. They specialize in frequency converters, power modules, inverters, and switching mode power supplies, holding various domestic and international quality certifications. The company operates under its independent brand "WangYatian" and serves customers in 156 countries worldwide.