1. Product Overview
The BRT-SG08 is a portable multifunction signal generator designed for generating and measuring current, voltage, and PWM signals. It features a 2.0-inch TFT color screen for clear display and a digital encoder knob for precise adjustments. This device is suitable for various electrical DIY projects and professional applications.


2. Setup and Assembly
Before using the BRT-SG08, ensure all components are present and follow these assembly steps. Always turn off the power supply before wiring.
2.1 Packing List
- Multi-functional generator host: 1 piece
- Phillips screwdriver: 1 piece
- Type-C charging cable: 1 piece
- Crocodile clip test leads: 4 pcs
2.2 Initial Assembly
The device comes with a built-in battery. The following video demonstrates the battery installation and knob assembly process.
Steps for Assembly (as shown in Video 1):
- Connect the battery cable to the circuit board connector.
- Place the circuit board into the bottom casing.
- Peel off the protective film from the battery and adhere it to the designated area on the circuit board.
- Align the top casing with the circuit board and bottom casing, ensuring a snug fit.
- Install the digital encoder knob onto its shaft.
- Secure the casing with the provided screws using the Phillips screwdriver.
- Peel off any surface protective film from the sticker on the device screen.
3. Operating Instructions
3.1 Power On/Off
- The left button labeled "NO" is for power on.
- The right button labeled "OFF" is for power off.
3.2 Main Screen Display
The main page is divided into three parts: the menu bar, input measurement display, and output adjustment display.

- Input Display: Shows the applied current and voltage in "Actual Value" and "Display Value". If the display value is outside the set range, it will show "-----".
- Output Control: Allows adjustment of current, voltage, and PWM output.
3.3 Navigation and Adjustment
- "Down" Key: Used to switch the selected parameter downwards. In the "measurement page", long pressing this key can switch between the "measurement page" and the "help/setting menu".
- "Left" Key: Used to move the editing cursor when adjusting numerical parameters.
- Encoder Knob:
- Clockwise rotation: Increases the adjustable value parameter.
- Counter-clockwise rotation: Decreases the adjustable value parameter.
- Press (OK<confirm key>): Confirms selections or enters menus.
3.4 Settings Menu
Tap the "Menu Bar" or long press the "down" key to enter the help and settings pages. The Settings Menu Page is used to set related system parameters and contains four parts:

- System Settings (SYS-SETUP):
- Language: Press OK to switch between Chinese/English.
- Screen Brightness: Press OK to adjust brightness (LV.1-LV.4).
- Factory Reset: Press OK, confirm "Yes" to reset.
- Current Settings (I-SETUP): Adjust parameters like output range, low/high end, mode, display limits, and current compensation. The "output range" is switched by OK<Enter key>.
- Voltage Settings (V-SETUP): Similar to Current Settings.
- System Information (INST-INFO): Displays hardware and software version numbers.
3.5 Current Output Disconnection
If the current output does not form an effective current loop (resistance > 500Ω), the main page displays a disconnection mark "CR", and the current output icon will not be displayed.
4. Wiring and Connections
The BRT-SG08 features a 15EDGK3.81 (9P) pluggable terminal block for various connections. Terminal numbers are counted from left to right (1-9).
4.1 Terminal Functions
| Terminal Code | Function | Note |
|---|---|---|
| GND | Optional Power supply input 24V- | If battery is empty. User can connect external 24VDC operating power supply input to these terminals. |
| 24V | Optional Power supply 24V + | |
| mAi | Current signal input+ | -50mA to 50mA input + |
| Vi | Voltage signal input+ | -50V to 50V input + |
| LP+ | Sink current mode 24V external power supply input | Sink/passive current signal output: LP+ is connected to external 24V+, output signal via mAo to control external current from 24V. |
| mAo | Current signal output + | Source current signal output: mAo is signal output +, GND is the common GND. |
| Vo | Voltage signal output + | Voltage signal output: Vo is volt signal output+, GND is the common GND. |
| PWM | PWM signal output + | |
| GND | Signal input and output Common GND- |
4.2 Connection Diagrams
1-GND is the same as 9-GND and can be arbitrarily connected.
The 24V terminal is for external power input to power/charge the meter.
Current Output (Active Mode): The output of the meter (6-mAo 9-GND) corresponds to the positive and negative current input of the PLC. The voltage output (7-Vo 9-GND) corresponds to the positive and negative voltage input of the PLC. Can be measured directly with a multimeter.
Current Sink Two-Wire Output (Passive Mode): Connect 24V+ to the 5-LP+ terminal. Output from the 6-mAo terminal to control the current of the external 24V. The meter acts as a variable resistor. Direct measurement cannot detect the current. Can be replaced with a passive two-wire pressure/temperature sensor.
PWM Pulse Output: High level is 5V, low level is 0V. It can directly drive buzzers, LEDs, optocouplers, or connect to a 12V/24V system via an external level conversion module.


5. Maintenance and Care
- Keep the device clean and dry. Avoid exposure to dust, moisture, and extreme temperatures.
- Do not use abrasive cleaners or solvents. Wipe with a soft, dry cloth.
- Ensure all connections are secure before operation to prevent damage.
- Store the device in a safe place when not in use.
6. Troubleshooting and Calibration
6.1 General Troubleshooting
- If the device operates abnormally or is damaged, check if it was used beyond the technical specifications.
- If the current output shows a "CR" disconnection mark, verify the current loop is properly formed and resistance is not too high.
6.2 Current Compensation (Calibration)
To adjust output accuracy, enter the current compensation page via the menu. This page allows adjustment of three compensation output points: 4mA, 12mA, and 20mA.

Calibration Steps:
- Connect the output line to a multimeter.
- Turn the knob to the left for "minus" values and to the right for "plus" values.
- Adjust the "4mA" setting until the multimeter displays 4mA.
- Repeat for "12mA" and "20mA".
- Switch the current to output synchronously.
- Once completed, the system will automatically save the settings.
Note: Compensation values are for internal adjustment and not expressed in standard units.
7. Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | BRT SG08 |
| DIY Supplies | Electrical |
| Certification | CE, RoHS |
| Display Size | 3.0 - 4.9 Inches (2.0 inch TFT color screen, 320*240 pixels) |
| Voltage Measurement Range | ±50V, error less than 0.03V |
| Current Measurement Range | ±50mA, error less than 0.03mA |
| PWM Signal Output | Frequency 1-150 kHz adjustable, duty cycle 0-100% adjustable, fixed 5V amplitude voltage, driving current <20mA. Not suitable for 12V or 2V systems. |
| Voltage Signal Output | Default 0-10V, max. -12V to 12V, adjustable and calibratable, accuracy after calibration 0.03V, driving current 20mA, with short circuit protection. |
| Current Signal Output | Default 4-20mA; Max. 0-24mA, adjustable and calibratable, accuracy after calibration 0.05mA, resistance <500 ohms. |
| Digital Encoder Knob | 20 steps per revolution with push button |
| Terminal Connector | 15EDGK3.81 (9P) pluggable terminal block |
| Working Environment | 0-40℃, relative humidity <80% |
| Size (L x W x H) | 100 x 60 x 19.5mm |
| Knob Height | 15.4mm |
| Weight | 120g (with battery) |
| Storage Temperature | -25 to +65℃ |
| Humidity | <80% R.O. non-condensation |
| Battery Included | Yes |
| Battery Capacity | 3.7V, 1500mAH |
| Power Consumption | External 15-30V power supply: ~5W; Micro USB 5V power supply: 0.5A-1A |
7.1 Dimensions

8. User Tips
- The device is generally accurate for voltage and 4-20mA output.
- When using PWM output, be aware that there might be some noise on the positive half of the square wave, though this is typically not an issue for most applications.
- Remember to peel off the protective film from the screen for optimal visibility.
- When charging, the lower charging indicator light is red and turns green when fully charged. The battery icon on the screen will also indicate charge level.
9. Frequently Asked Questions (FAQ)
- Q: How long does the battery last on a full charge?
- A: The built-in 1500mAh battery can last 1-5 hours depending on the output load. A full charge typically takes more than 6 hours.
- Q: Can I use the PWM output for 12V or 24V systems?
- A: The PWM output has a fixed 5V amplitude. For 12V or 24V systems, an external level conversion module is required.
- Q: What should I do if the screen displays "-----"?
- A: This indicates that the displayed value is not within the configured display range. Check your settings in the Current or Voltage Settings menu.