Introduction
This manual provides essential information for the safe and efficient operation of your ANENJI 3KW 24V Hybrid Solar Inverter. This inverter is designed to convert DC power from solar panels and batteries into AC power for household appliances, supporting both off-grid and on-grid applications with a pure sine wave output and an integrated 100A MPPT solar charge controller. Please read this manual thoroughly before installation and use.

Image: ANENJI Off-Grid Hybrid Inverter, highlighting its 3KW, 24V, 120VAC, 3000W rated power, 100A Max Solar Charge Current, 4000W Max PV Array Power, 500VDC Max PV Array Open Circuit Voltage, and built-in Wi-Fi.
Safety Information
WARNING: Electrical Shock Hazard
- Installation must be performed by qualified personnel due to high voltage.
- Ensure proper grounding of the inverter.
- Do not place anything between the flat part of the inverter terminal; overheating may occur.
- Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
- Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
- Always disconnect all power sources (solar, battery, AC input) before performing any maintenance or wiring.

Image: Product precautions, including a diagram for connecting two 12V batteries in series for a 24V system, and warnings regarding shock hazards and terminal connections.
Product Overview
The ANENJI Hybrid Solar Inverter features a user-friendly interface and robust connectivity options. Below is a diagram identifying the main components and their functions.

Image: Front and rear view of the inverter with numbered labels indicating various ports, indicators, and controls.
- AC input
- AC output
- PV input
- Battery input
- Grounding
- RS485 communication port
- Built-in WIFI
- Power on/off switch
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons (ESC, UP, DOWN, ENTER)
- NC O NO (Normally Closed, Open, Normally Open)
Setup
1. Installation Environment
Choose a suitable location for the inverter, ensuring adequate ventilation and protection from direct sunlight, moisture, and dust. When selecting PV modules, consider the following parameters:
- Open circuit voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (500VDC).
- Open circuit voltage (Voc) of PV modules should be higher than the minimum battery voltage.

Image: Diagram showing the inverter connected to a house with solar panels and battery, emphasizing PV module selection criteria.
2. Wiring Instructions
Follow the diagram below for connecting your solar panels, utility grid, battery, and household appliances. Ensure all connections are secure and correctly polarized.

Image: Comprehensive wiring diagram illustrating connections between solar panels, generator, utility grid, battery, inverter, and various household loads.
Important Battery Connection Note (24V Model):
For a 24V battery system, connect two 12V batteries in series. Ensure positive (+) of one battery connects to negative (-) of the other, and the remaining positive and negative terminals connect to the inverter's battery input.
Operating Instructions
1. Power On/Off
- To power on: Ensure all connections are correct, then switch the Power On/Off switch (8) to the 'ON' position.
- To power off: Switch the Power On/Off switch (8) to the 'OFF' position.
2. LCD Display and Function Buttons
The LCD display (9) provides real-time operational status. Use the function buttons (13) - ESC, UP, DOWN, ENTER - to navigate menus and adjust settings.

Image: Close-up of the inverter's front panel, showing the LCD display and the ESC, UP, DOWN, ENTER function buttons.
3. Operating Modes
The inverter supports various operating configurations depending on the availability of battery, solar power, and AC power.

Image: Diagram illustrating four operational scenarios: 1) Solar Power and AC Power available (with battery), 2) Solar Power and AC Power not available (with battery), 3) Solar Power available (without battery), and 4) AC Power available (without battery).
- Operation with Battery Connected:
- Solar Power and AC Power available: The inverter prioritizes solar power, then AC power, to charge the battery and supply loads.
- Solar Power available, AC Power not available: Solar power charges the battery and supplies loads.
- Operation without Battery Connected:
- Solar Power available: Solar power directly supplies loads.
- AC Power available: AC power directly supplies loads.
Maintenance
- Regular Inspection: Periodically check all wiring connections for tightness and signs of corrosion.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling. The inverter features a detachable dust cover for easier cleaning in harsh environments.
- Battery Maintenance: Follow the battery manufacturer's guidelines for maintenance to ensure optimal performance and lifespan.

Image: Product characteristics, mentioning the detachable dust cover for maintenance in harsh environments.
Troubleshooting
This section provides solutions to common issues. For problems not listed here, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery connection, low battery voltage, power switch off. | Check battery connections and voltage. Ensure power switch is ON. |
| No AC output | Overload, short circuit, battery low, fault indicator on. | Reduce load. Check for short circuits. Charge battery. Refer to fault codes on LCD. |
| Solar charging not working | PV input incorrect, PV array voltage too low/high, solar panels shaded. | Verify PV connections. Check PV array voltage against specifications. Clear any shading. |
| Overheating | Blocked ventilation, excessive ambient temperature, continuous overload. | Clear vents. Ensure proper airflow. Reduce load. |
Specifications
Detailed technical specifications for the ANENJI ANJ-3KW-24V-LV-WIFI Hybrid Solar Inverter.

Image: A table listing comprehensive product parameters including input, output, battery, solar charger, and physical/environmental specifications.
| Category | Parameter | Value |
|---|---|---|
| General | Model | ANJ-3KW-24V-LV-WIFI |
| Capacity | 3KVA/3KW | |
| Parallel Capability | NO | |
| Input | Nominal Voltage | 110/120VAC |
| Acceptable Voltage Range | 95-140VAC (For personal Computer); 70-140VAC (For Home Appliances) | |
| Frequency | 50/60 Hz (Auto sensing) | |
| Output | Nominal Voltage | 110/120VAC ±5% |
| Surge Power | 6000VA | |
| Waveform | Pure Sine wave | |
| Transfer Time | 10ms (For personal Computer); 20ms (For Home Appliances) | |
| Peak Efficiency (PV to INV) | 97% | |
| Peak Efficiency (Battery to INV) | 93% | |
| Overload Protection | 5s@>=140% load; 10s@110%~140% load | |
| Battery | Battery Voltage | 24VDC |
| Floating Charge Voltage | 27VDC | |
| OverCharge Protection | 33VDC | |
| Solar Charger & AC Charger | Max.PV Array Power | 4000W |
| Max.PV Array Open Circuit Voltage | 500VDC | |
| PV Array MPPT Voltage Range | 60VDC~450VDC | |
| Max.Solar Input Current | 18A | |
| Max.Solar Charge Current | 100A | |
| Max.AC Charge Current | 60A | |
| Physical | Dimensions (D x W x H) | 312.4 x 350 x 114.5 MM |
| Package Dimensions (D x W x H) | 475 x 390 x 180 MM | |
| Net Weight | 8.5 KG | |
| Communication Interface | Dry contact + RS485 + WIFI | |
| Environment | Operating Temperature Range | -10°C to 50°C |
| Storage Temperature | -15°C to 50°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Ingress Protection | IP21 |
User Tips
- Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to maximize energy harvest.
- Monitor Performance: Utilize the built-in WiFi monitoring feature to track your system's performance and identify any potential issues early.
- Battery Health: Regularly check battery connections and ensure they are clean and tight to prevent power loss and extend battery life.
- Load Management: Be mindful of the inverter's rated capacity (3000W) to avoid overloading, especially with high-surge appliances.
Warranty and Support
Your ANENJI Hybrid Solar Inverter comes with a standard manufacturer's warranty. For warranty claims, technical support, or any questions regarding the product, please contact ANENJI customer service through your purchase platform or the official ANENJI website.
Please retain your proof of purchase for warranty validation.