1. Product Overview
The ERICKHILL RT-100 is a portable, hand-held electromagnetic field (EMF) radiation detector designed to measure both electric field (E-field) and magnetic field (H-field) radiation. It features a clear 2.25-inch LCD screen, sound-light alarm, and is suitable for various applications including home appliance testing and environmental monitoring.
Figure 1: ERICKHILL RT-100 EMF Meter
Key Features:
- Precise Measurement: Equipped with a built-in electromagnetic radiation sensor for accurate readings. Measures magnetic field radiation in mG/µT and electric field in V/m. (Note: This device does not test RF values).
- Sound-Light Alarm: Visual (red screen, flashing indicator) and audible (buzzer) alerts when radiation levels exceed preset safety thresholds (0.4µT / 4mG or 40V/m). The buzzer can be silenced for quiet environments.
- Multifunction Display: Supports average (AVG) and peak (VPP/MAX) value readings. Data hold function allows for easy recording of measurements.
- Clear LCD Screen: A large, backlit 2.25-inch LCD ensures easy readability in various lighting conditions.
- Convenient Power: Features a low battery indicator and automatic power-off after 5 minutes of inactivity to conserve energy. Type-C rechargeable for ease of use.
- Wide Applications: Ideal for testing radiation from household appliances (TVs, computers, printers, microwave ovens, refrigerators), cell towers, and for general environmental EMF detection.
2. Package Contents
Upon opening your ERICKHILL RT-100 package, please ensure all items listed below are present and in good condition:
- 1 x ERICKHILL RT-100 EMF Meter
- 1 x USB Type-C Charging Cable
- 1 x User Manual (this document)
Figure 2: ERICKHILL RT-100 Package Contents
3. Setup
3.1 Initial Charging
The ERICKHILL RT-100 comes with a built-in rechargeable battery. Before first use, or if the low battery indicator is shown, please charge the device using the provided Type-C USB cable.
- Connect the small end of the Type-C USB cable to the charging port on the side or bottom of the EMF meter.
- Connect the larger end of the USB cable to a standard USB power adapter (not included) or a computer USB port.
- The charging indicator on the device will show its status (e.g., a charging icon on the screen).
- Once fully charged, disconnect the cable.
Figure 3: Type-C Rechargeable Feature
3.2 Powering On/Off
Press and hold the Power button (usually marked with a power symbol) located on the front panel to turn the device ON or OFF.
4. Operating Instructions
The ERICKHILL RT-100 is designed for straightforward operation. Familiarize yourself with the buttons and display before use.
Figure 4: ERICKHILL RT-100 Controls and Display
4.1 Understanding the Display
The 2.25-inch LCD screen displays real-time readings for both Electric Field (E-field) and Magnetic Field (H-field). It also shows the current mode (AVG/VPP), unit of measurement, battery status, and alarm indicators.
Figure 5: Detailed view of the 2.25-inch LCD screen
4.2 Changing Measurement Units
Press the UNIT button to cycle through the available measurement units:
- Electric Field: V/m (Volts per meter)
- Magnetic Field: µT (microTesla) or mG (milliGauss)
4.3 Average (AVG) / Peak (VPP) Mode
Press the AVG/VPP button to switch between Average and Peak value display modes. Average mode shows the typical radiation level, while Peak mode captures the highest detected value.
4.4 Data Hold Function
Press the HOLD button to freeze the current readings on the screen. This is useful for noting down stable measurements. Press HOLD again to release and resume real-time measurement.
4.5 Sound-Light Alarm
The device is equipped with a sound and light alarm system. When the detected radiation level exceeds the safety threshold (0.4µT / 4mG for magnetic field or 40V/m for electric field), the screen will turn red, an indicator light will flash, and a buzzer will sound. To mute the buzzer, press the Power button briefly while the alarm is active.
Figure 6: Alarm Indication during EF and MF Testing
4.6 Performing Measurements
To get accurate readings, hold the meter with the front sensing area pointed towards the object or area you wish to test. Move the meter slowly around the area to detect variations in EMF levels.
Figure 7: Examples of EMF Meter Applications
Figure 8: Testing cell towers and computers
Figure 9: Testing a microwave oven
5. Maintenance
5.1 Cleaning
To clean the device, wipe it gently with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.
5.2 Storage
Store the ERICKHILL RT-100 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the battery is partially charged and recharge it periodically to maintain battery health.
5.3 Battery Care
The device uses a built-in rechargeable battery. Avoid fully discharging the battery frequently. Recharge when the low battery indicator appears. Do not attempt to replace the internal battery yourself.
6. Troubleshooting
- Device does not power on: Ensure the battery is charged. Connect to a power source using the Type-C cable and try again.
- No readings displayed: Check if the device is powered on. Ensure the front sensing area is pointed towards the source.
- Alarm constantly active: The device is detecting EMF levels above the threshold. Move away from the source or consider muting the buzzer if the environment is known to have high EMF.
- Screen is dim or unreadable: Ensure the backlight is on (if applicable, check manual for specific button). Recharge the battery if it's low.
- Device automatically turns off: This is a normal feature (auto power-off after 5 minutes of inactivity) to save battery. If it turns off during active use, check battery level.
7. Specifications
| Category | Parameter |
|---|---|
| General |
Brand: ERICKHILL Type: EMF Meter Model: RT-100 Color: Black |
| Display | Screen Size: 2.25-inch LCD |
| Measurement Units |
Electric Field: V/m Magnetic Field: µT / mG |
| Alarm Threshold |
Magnetic Field: 0.4µT (4mG) Electric Field: 40V/m |
| Features | Sound-Light Alarm, AVG/VPP Mode, Data Hold, Auto Power Off, Low Battery Indicator, Type-C Rechargeable |
| Power | Battery Included: Yes (Rechargeable) |
| Certifications | CE |
| Dimensions & Weight |
Product Weight: 0.25kg Package Weight: 0.3kg Package Size (L x W x H): 18 x 13 x 5.5 cm |
| Origin | Mainland China |
8. User Tips
- Initial Power-On: When turning on the device, try to do so away from strong EMF sources to ensure a stable baseline reading.
- Understanding Fields: Remember that the meter measures both electric and magnetic fields. Electric fields are often present even when devices are off but plugged in, while magnetic fields are typically associated with current flow (device in operation).
- RF Exclusion: This meter is specifically for electric and magnetic fields and does not detect radio frequency (RF) radiation. For RF detection, a different type of meter is required.
- Movement for Detection: Move the meter slowly and deliberately around the area or object you are testing. EMF fields can vary significantly over short distances.
- Interpreting Alarms: The alarm thresholds are set to common safety guidelines. Continuous alarms in an area suggest higher than recommended EMF exposure.
9. Warranty and Support
The ERICKHILL RT-100 EMF Meter is designed for reliability and performance. For any technical support or warranty inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website.
Please retain your proof of purchase for warranty purposes.