1. Introduction
Thank you for choosing the STEPPERONLINE DM556EC Digital Stepper Driver. This manual provides essential information, precautions, and operational guidance for safe and effective use of the product. Please read it carefully before installation and operation.
1.1 Product Overview
The DM556EC bus stepper servo driver is a digital stepper driver featuring EtherCAT bus communication and intelligent motion control. It supports the CoE protocol as a standard EtherCAT slave driver unit, compatible with mainstream master controllers.
Video: Overview of the DM556EC Digital Stepper Driver.
1.2 Key Features
- New generation 32-bit DSP technology for high performance, stability, low noise, and low vibration.
- Operating voltage range: DC24V to 50V.
- Adjustable working current up to a maximum of 4A.
- 100BASE-TX Ethernet transmission standard, 100Mbps full-duplex communication.
- Supports CANopen over EtherCAT (CoE) and complies with CiA 402 standards.
- Supports Cyclic Sync Position, Profile Position, Profile Velocity, Homing, and other working modes.
- Double-port RJ45 connector for EtherCAT communication.
- Four optical isolation input ports (12V to 24V input).
- Two optical isolation output ports.
- Subdivision settings from 400 to 51200, supporting electronic gear.
- Smooth and accurate current control for low motor heat.
- Built-in protection functions: overvoltage, undervoltage, overcurrent.
1.3 Application Field
This driver is primarily used in lithium industry equipment, 3C non-standard equipment, marking machines, stage lighting, and other automation equipment.
2. Safety Information
Improper operation of this product can lead to serious consequences. Please adhere to all safety guidelines.
⚠ Attention!
- ⚠ Reminds you to pay attention to the main points in the text.
- ⚠ Indicates that improper operations may result in personal injury or equipment damage.
The design and manufacture of this product do not inherently protect against mechanical system threats to personal safety. Users must implement appropriate safety protection measures in their mechanical system designs to prevent accidents from improper operation or product abnormalities.
Product contents are subject to change without notice due to ongoing improvements. The manufacturer is not responsible for user modifications to the product.
3. Package Contents
Image: Decorative header for Package List.
The package includes the following items:
- 1 x DM556EC Driver
- 1 x CABLE-PC-2 (RS232 debugging cable)
4. Specifications
4.1 Electrical Characteristics
Image: Decorative header for Electrical Specification.
| Argument | Minimum Value | Typical Value | Maximum Value | Unit |
|---|---|---|---|---|
| Continuous output current | 0 | - | 4.0 | A |
| Input supply voltage | 24 | 24/48 | 50 | Vdc |
| Logic input current | 5 | 10 | 50 | mA |
| Logic input voltage | 12 | 24 | 24 | V |
| Insulation resistance | 100 | - | - | MΩ |
4.2 Operating Environment and Physical Specifications
Image: Decorative header for Operating Environment and other Specifications.
| Parameter | Value |
|---|---|
| Cooling | Natural Cooling or Forced cooling |
| Use Occasion | Avoid other heating equipment, dust, oil mist, corrosive gas, strong vibration, flammable gas, and conductive dust. |
| Ambient Temperature | 0℃ - 50℃ |
| Humidity | 40% - 90%RH (non-condensation) |
| Vibration | 10-55Hz/0.15mm |
| Storage Temperature | -20℃ - 70℃ |
| Weight | Approx. 244g (8.61oz) |
| Dimensions (L x W x H) | 25 cm x 15 cm x 10 cm |
5. Installation
5.1 Mounting Dimensions
Image: Diagram showing the mounting dimensions of the DM556EC driver (unit: mm).
5.2 Installation Methods
For optimal cooling, install the driver upright to facilitate strong air convection over its surface. If necessary, install a fan near the driver to force heat dissipation. This ensures the driver operates within its reliable temperature range (typically below 50℃), and the motor operating temperature remains below 80℃.
Image: Diagram illustrating vertical mounting for multiple stepper drivers to ensure proper airflow and cooling.
6. Driver Ports and Wiring
6.1 Wiring Diagram
Image: Front view of the DM556EC driver, detailing LED codes, RS232 debugging port, EtherCAT communication ports, input/output signal ports, motor port, and power port.
⚠ Attention!
- Wiring personnel must have professional ability.
- Do not perform live wiring.
- Wiring must only be carried out after the installation is firm.
- Ensure correct power supply connection; input voltage must not exceed 50VDC.
6.2 Port Definition
6.2.1 Debugging Interface (RS232)
| Pin | Symbol | Name | Function |
|---|---|---|---|
| 1 | TX | Debugging interface | Connect to debug software. |
| 2 | RX | ||
| 3 | GND | ||
| 4 | NC |
Image: RS232 debugging cable (CABLE-PC-2) used for connecting to debug software.
6.2.2 EtherCAT Communication Port
The driver features two standard RJ45 network ports for EtherCAT data transmission and reception, supporting front and back links.
| Pin | Symbol | Function |
|---|---|---|
| 1 | TX+ | Two standard RJ45 network ports, support EtherCAT data sending and receiving, site front and back links. |
| 2 | TX- | |
| 3 | RX+ | |
| 4 | NC | |
| 5 | NC | |
| 6 | RX- | |
| 7 | NC | |
| 8 | NC |
6.2.3 Input/Output Signal Port
| Symbol | Name | Function |
|---|---|---|
| Y0 | Output terminal 0 | Digital output signal |
| Y1 | Output terminal 1 | |
| XCOM | Input common terminal | Input signal public end |
| YCOM | Output common terminal | Output signal common end |
| X0 | Input terminal 0 | Single-ended digital input signal, total positive connection, support 12V~24V. |
| X1 | Input terminal 1 | |
| X2 | Input terminal 2 | |
| X3 | Input terminal 3 |
6.2.4 Motor Output Port
| Symbol | Name | Function |
|---|---|---|
| A+ | A+ | Two phase stepper motor connector |
| A- | A- | |
| B+ | B+ | |
| B- | B- |
6.2.5 Power Input Port
| Symbol | Name | Function |
|---|---|---|
| V+ | Power interface | DC24-50V |
| V- |
6.3 Input/Output Port Operation
The driver provides 4 photoelectric isolated input interfaces and 2 optocoupler isolated output signals.
Cables to the input ports support 12V to 24V voltage. The level pulse width of the input signal needs to be greater than 10ms for proper driver response. The timing diagram for X0-X3 is shown below:
Image: Input terminal connection reference circuit diagram.
The driver provides two optocoupler isolated output terminals. The wiring is as follows:
Image: Y0-Y1 output terminal internal circuit diagram.
7. Operation
The DM556EC driver supports various operational modes via EtherCAT communication, including:
- Cyclic Synchronous Position Mode: For precise, synchronized position control.
- Profile Position Mode: For executing predefined position profiles.
- Profile Velocity Mode: For controlling motor speed based on velocity profiles.
- Homing Mode: For finding a reference or home position.
Detailed configuration and control for these modes are typically managed through a compatible EtherCAT master controller and its associated software. Refer to your master controller's documentation for specific programming and setup instructions.
8. Maintenance
To ensure the longevity and optimal performance of your DM556EC driver, consider the following maintenance guidelines:
- Cleaning: Regularly clean the driver's exterior to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth. Avoid using solvents or abrasive cleaners.
- Environmental Control: Maintain the operating environment within specified temperature and humidity ranges. Ensure adequate ventilation and avoid exposure to corrosive gases, oil mist, or excessive vibration.
- Connection Integrity: Periodically check all wiring connections for tightness and signs of wear or corrosion. Loose connections can lead to intermittent operation or damage.
- Heat Management: Ensure that the cooling system (natural convection or forced air) is unobstructed and functioning effectively to keep the driver and motor within their safe operating temperatures.
9. Troubleshooting
9.1 Driver Status Indicators (LED Codes)
The DM556EC driver uses LED indicators to communicate its status and any alarm conditions. Refer to the table below for interpretation:
| Name | Color | Status | Function |
|---|---|---|---|
| PWR | Green | Solid Green | Power On |
| ALM | Red | Flash 1 time | Overcurrent |
| Flash 2 time | Overvoltage | ||
| Flash 3 time | Undervoltage | ||
| Flash 6 time | Communication error | ||
| Flash 8 time | Sensor error | ||
| RUN | Green | OFF | INIT Status or power-off status |
| Blinking | Pre-Operational status | ||
| Single Flash | Safe-Operational status | ||
| Flickering | BootStrap status | ||
| L/A | Green | ON | Operational status |
| OFF | No error or power failure status | ||
| ERR | Red | Flickering | EEPROM load error |
| Single Flash | Status register error | ||
| Double Flash | The process data watchdog timed out | ||
| ON | PDI The watchdog timed out | ||
| OFF | The physical layer link is not established | ||
| L/A | Green | ON | The physical layer link is established |
| Flickering | The physical layer link has data interaction |
9.2 General Troubleshooting Methods
If you encounter issues with your DM556EC driver, consult the following table for possible causes and solutions:
| Symptom | Possible Causes | Solutions |
|---|---|---|
| Motor failure | The power light is off | Check the power supply circuit. Ensure the power supply is normal. |
| The motor locks the shaft but does not turn | The IO signal is weak, increase the signal current. | |
| Too little speed | Adjust the speed selection. | |
| Whether the release signal MF is connected | Ensure the release signal MF is not connected. | |
| Instruction input error | Check if the upper computer has a switch output. | |
| Motor steering error | Motor reversal | Replace motor wiring sequence or adjust instruction direction. |
| The motor line has a break | Check whether the cable is in poor contact. | |
| The motor has only one direction | Input port damage. | |
| Alarm indicator light | The motor wire is connected incorrectly | Check the wiring. |
| The voltage is too high or low | Check power supply. | |
| The motor or drive is damaged | Replace the motor or drive. | |
| Signal interference | Eliminate interference, ensure reliable grounding. | |
| Instruction input error | Check the upper computer instructions to ensure correct output. | |
| Wrong position or speed | Speed setting error | Check the DIP switch status and connect it correctly. |
| Motor tripping | Check whether the command speed is too large and the motor selection is small. | |
| The driver terminal is burned out | Short-circuit between terminals | Check the power polarity or external short circuit. |
| The internal resistance between terminals is too large | Check whether excess solder is added to the wire and wire connection to form tin pellets. | |
| Motor stalling | The acceleration and deceleration time is too short | Reduce the command acceleration or increase the driver filter parameter. |
| Motor torque too small | Select a high torque motor. Check the load weight and quality, adjust the mechanical structure. | |
| Too little current | Check DIP switches to increase the output current of the driver. |
10. User Tips
- Always ensure your power supply is stable and within the specified voltage range (DC24-50V) to prevent undervoltage or overvoltage errors.
- For optimal performance and longevity, consider forced cooling with a fan, especially in enclosed spaces or high-temperature environments.
- Double-check all wiring connections, particularly for motor phases and input/output signals, to avoid incorrect operation or damage.
- When debugging, utilize the provided RS232 cable and compatible software for precise configuration and diagnostics.
11. Warranty and Support
For technical support or inquiries, please contact STEPPERONLINE using the information below:
- Address: 15-4, #799 Hushan Road, Jiangning, Nanjing, China
- Tel: 0086-2587156578
- Web: www.omc-stepperonline.com
- Sales: sales@stepperonline.com
- Support: technical@stepperonline.com
©2025 All Rights Reserved