SONGGER PT-506

Contents

PT-506 Water Pump Pressure Sensor Transmitter User Manual

Model: PT-506 | Brand: SONGGER

1. Introduction

The SONGGER PT-506 is a robust stainless steel pressure sensor transmitter designed for accurate pressure monitoring in various industrial applications. It is suitable for water pumps, hydraulic systems, air compressors, and liquid media. This device converts measured pressure into a standardized 4–20 mA current signal, making it ideal for integration into industrial control systems. Key features include IP67 protection, high measurement accuracy, and stable signal transmission, ensuring reliable performance in demanding environments.

2. Specifications

The PT-506 sensor is available in various configurations. The default configuration is an elbow type with a 2m cable and G1/4 thread. Other options are available upon request.

PT-506 Water Pump Pressure Sensor Transmitter with key specifications

Figure 1: PT-506 Product Overview with Key Specifications

Technical Parameters

ParameterSpecification
Pressure Range0–1.0 MPa / 0–1.6 MPa / 0–2.5 MPa
Output Signal4–20 mA (two-wire system)
Power Supply24 VDC (operating range 10–36 VDC)
Overload Pressure200% FS
Accuracy±0.5% FS
Temperature Drift±0.03% FS/°C
Operating Temperature–40 °C to +85 °C
Waterproof RatingIP67
Electrical ConnectionLead wire, 22 AWG tinned shielded cable
Cable Length2 m standard, optional 5 m or 10 m
Thread ConnectionG1/4 standard, optional G1/2 or M20 × 1.5, custom threads available
MaterialStainless steel housing
Display Unitbar
Battery IncludedNo
High-concerned chemicalNone
OriginMainland China

Package Contents

  • Pressure sensor transmitter ×1

3. Features

  • High Accuracy Pressure Sensing: Delivers ±0.5%FS precision for reliable monitoring.
    High Accuracy Pressure Sensing feature

    Figure 2: High Accuracy Sensing

  • Waterproof & Dustproof (IP67): Equipped with O-ring seal and built-in gasket for moisture resistance, ensuring durability in harsh conditions.
    Waterproof and Dustproof IP67 feature

    Figure 3: IP67 Waterproof Design

  • Anti-mistake Plug Design: Features a foolproof slot to prevent reverse insertion and potential sensor damage during connection.
    Anti-mistake Plug Design feature

    Figure 4: Anti-mistake Plug

  • Enhanced Signal Transmission: Utilizes 22AWG tinned shielded wire for superior anti-interference capabilities and signal integrity, even over longer distances.
    Enhanced Signal Transmission feature with shielded wire

    Figure 5: Shielded Cable for Signal Integrity

  • Multiple Cable Lengths Available: Standard 2m cable; 5m and 10m options are available for different installation requirements.
    Multiple Cable Lengths Available feature

    Figure 6: Cable Length Options

  • Flexible Thread Options: G1/4 (13mm) is standard; G1/2 (20mm) and M20×1.5 threads are available upon request for broader compatibility.
    Flexible Thread Options feature

    Figure 7: Thread Connection Types

4. Applications

The PT-506 pressure sensor transmitter is widely applicable in various fields:

  • Industrial automation systems
  • Hydraulic systems
  • Air compressors
  • Liquid level monitoring
  • Water pumps

It is compatible with non-corrosive media such as water, oil, and air.

Diagram showing various applications for the pressure sensor

Figure 8: Typical Application Scenarios

5. Setup and Installation

5.1. Preparation

  1. Verify Pressure Range: Ensure that the selected pressure range of the PT-506 matches your application requirements.
  2. Check Power Supply: Confirm that the power supply voltage available is within the specified operating range of 10–36 VDC.
  3. Confirm Thread Compatibility: Verify that the sensor's thread specification (e.g., G1/4) is compatible with the installation port on your system.
  4. Disconnect Power: Always disconnect system power before beginning any installation work to prevent electrical hazards.

5.2. Installation

  1. Apply Sealing: Apply appropriate sealing tape (e.g., PTFE tape) or a sealing gasket to the threaded connection of the sensor.
  2. Mount Sensor: Carefully install the sensor into the designated pressure port on your system.
  3. Tighten Connection: Use a suitable wrench to tighten the sensor. Do not apply excessive torque, as this can damage the sensor or the port.
  4. Cable Routing: Route the sensor cable away from any strong electromagnetic interference sources (e.g., power cables, motors) to ensure stable signal transmission.

6. Electrical Connection

The PT-506 is a two-wire system. Connect the positive and negative wires according to your control system's wiring diagram. Ensure correct polarity before applying power.

PT-506 sensor with red and black wires for electrical connection

Figure 9: Electrical Connection (Red: 24V Input, Black: Signal Output)

Wiring Diagram

  • Red Wire: Connect to 24VDC input terminal (positive).
  • Black Wire: Connect to signal output terminal (negative/ground).

WARNING: Incorrect wiring may result in equipment damage or malfunction. Always ensure correct polarity.

7. Operation and Data Reading

Once the PT-506 transmitter is installed and correctly wired, and power is applied, it will begin to output a 4–20 mA current signal that is directly proportional to the applied pressure.

  • 4 mA Output: Corresponds to zero pressure (0 MPa).
  • 20 mA Output: Corresponds to the full-scale pressure of the sensor (e.g., 1.0 MPa, 1.6 MPa, or 2.5 MPa, depending on the model).

To read the corresponding pressure value, connect the sensor's output to a PLC (Programmable Logic Controller), a dedicated controller, or a display instrument that is configured to accept a 4–20 mA input signal. The receiving device will convert the current signal back into a pressure reading.

8. Maintenance

8.1. Storage

  • Store the product in a dry, well-ventilated environment.
  • Keep away from corrosive gases.
  • Avoid long-term exposure to high humidity or extreme temperatures.
  • If the sensor is not used for an extended period, protect the threaded port with a dust cap to prevent contamination.

8.2. Cleaning

  • Clean the exterior of the sensor with a soft, dry cloth.
  • Do not use aggressive solvents or abrasive cleaners, as these can damage the housing or seals.

8.3. Regular Inspection

  • Regularly inspect the wiring and sealing integrity to ensure continued measurement reliability and prevent leaks.

9. Troubleshooting

If you encounter issues with your PT-506 pressure sensor, consider the following common problems and solutions:

  • No Output or Incorrect Reading:
    • Check the power supply voltage; ensure it is within 10-36 VDC.
    • Verify the electrical connections for correct polarity (Red to 24V+, Black to Signal/GND).
    • Ensure the pressure range of the sensor matches the application's expected pressure.
    • Check for strong electromagnetic interference near the cable routing.
    • Confirm the receiving instrument (PLC, controller) is correctly configured for 4-20 mA input.
  • Sensor Damage or Leakage:
    • Inspect for signs of excessive torque during installation.
    • Ensure the measured medium is compatible with stainless steel and is not corrosive or highly viscous.
    • Verify that the operating temperature and pressure are within the specified limits.
    • Check for mechanical shock or vibration that could have damaged the sensor.
    • Ensure the cable connection is not immersed in water and that all seals are intact.
  • Inconsistent Readings:
    • Check for air bubbles or debris in the pressure line.
    • Ensure stable power supply.
    • Verify proper grounding and shielding to minimize electrical noise.

10. Precautions and Safety Warnings

General Precautions

  • Use the sensor only within its specified pressure range. Do not exceed 200% of full-scale pressure.
  • Ensure the medium being measured is compatible with stainless steel. Corrosive or highly viscous media should be verified before use.
  • Operate the device within the specified temperature range of -40 °C to +85 °C.
  • Avoid mechanical shock, excessive vibration, and pulling on the cable during installation and operation.
  • Ensure proper grounding and shielding of the electrical connections to minimize electrical interference.
  • Do not immerse the cable connection in water. While the sensor body meets IP67 protection, improper cable sealing can reduce the overall protection level.

Safety Warnings (EU Market Reference)

WARNING!

  • Installation must be performed by qualified personnel familiar with electrical and hydraulic systems.
  • Ensure the system is depressurized before installation or removal of the sensor.
  • Incorrect wiring may result in equipment damage or malfunction.
  • Do not use the device in explosive atmospheres unless it is separately certified for ATEX compliance.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE directives for electronic waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

11. User Tips & Frequently Asked Questions (FAQs)

User Tips

  • For optimal performance, ensure the sensor is installed in a location free from excessive vibration and temperature fluctuations.
  • Regularly check the integrity of the cable and connections, especially in industrial environments, to prevent signal degradation.
  • When customizing cable length or thread type, always confirm specifications with the supplier to ensure compatibility and proper function.

FAQs

Q1: Is the sensor compatible with both water and oil?
A1: Yes, it is suitable for non-corrosive media like water, air, and machine oil.
Q2: Can I get a G1/2 (20mm) thread version?
A2: Yes, please contact us for customization options regarding thread sizes.
Q3: What is the default cable length, and can I choose a longer one?
A3: The standard cable length is 2 meters. 5m and 10m versions are also available for customization.

12. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.

13. Support

For technical consultations, bulk orders, or customized products, please feel free to contact us:

Contact information for support including WhatsApp and Email

Figure 10: Contact Information

  • WhatsApp: +86 13311678550
  • Email: miazhao008@gmali.com
Documents and downloads